ICY DOCK MB155SP-B

ICY DOCK FatCage MB155SP-B 5-Bay 3.5" SATA Hot-Swap Backplane Cage User Manual

Model: MB155SP-B | Brand: ICY DOCK

1. పరిచయం

The ICY DOCK FatCage MB155SP-B is a 5-bay hot-swappable backplane cage designed to accommodate five 3.5" SATA I/II/III hard drives within three standard 5.25" drive bays of a computer chassis. This unit provides efficient data storage expansion with hot-swap capabilities, enhanced cooling, and a robust design for various applications.

2. ఉత్పత్తి లక్షణాలు

  • Accommodates five 3.5" SATA I/II/III (SATA 6Gbps) hard drives.
  • Installs into three standard 5.25" device bays.
  • Full support for SATA Hot-Swap functionality.
  • Integrated 92mm cooling fan with adjustable speed for effective heat dissipation.
  • Full metal body construction for durability and thermal performance.
  • కాంపాక్ట్ మరియు స్థలాన్ని ఆదా చేసే డిజైన్.
  • Interchangeable EZ-Tray design for secure drive installation and maintenance.
  • Compatible with DataCage Classic MB45X, ICYBento MB559, and ICYCube MB561 series trays.
  • Utilizes 15-pin SATA power connectors for modern system compatibility.

3. ప్యాకేజీ విషయాలు

ప్యాకేజీలో అన్ని అంశాలు ఉన్నాయని నిర్ధారించుకోండి:

  • ICY DOCK FatCage MB155SP-B unit
  • 5 x Hard Drive Trays (EZ-Tray)
  • మౌంటు స్క్రూలు
  • వినియోగదారు మాన్యువల్ (ఈ పత్రం)

4. ఇన్స్టాలేషన్ గైడ్

4.1 Installing the MB155SP-B into a PC Chassis

  1. చట్రం సిద్ధం చేయండి: Ensure your computer is powered off and unplugged. Open the computer case and locate three consecutive empty 5.25" drive bays. Remove any bay covers or brackets as necessary.
  2. Insert the Cage: Carefully slide the MB155SP-B unit into the three 5.25" bays from the front of the chassis until the mounting holes align.
  3. Secure the Cage: Use the provided screws to secure the MB155SP-B to the chassis on both sides. Ensure it is firmly seated to prevent vibration.
ముందు view of the ICY DOCK FatCage MB155SP-B installed in a chassis
మూర్తి 4.1: ముందు view of the MB155SP-B unit, showing its five drive bays.

4.2 Installing Hard Drives into EZ-Trays

  1. Remove a Tray: Press the release latch on the front of an EZ-Tray and pull the handle to slide the tray out of the MB155SP-B unit.
  2. హార్డ్ డ్రైవ్‌ను మౌంట్ చేయండి: Place a 3.5" SATA hard drive into the tray. Align the screw holes on the drive with the holes on the tray. Secure the drive using the provided screws.
  3. ట్రేని చొప్పించండి: Slide the loaded EZ-Tray back into the corresponding bay of the MB155SP-B until it clicks into place.
ICY DOCK FatCage MB155SP-B with drive trays partially extended
Figure 4.2: The MB155SP-B with its EZ-Trays partially extended, illustrating the drive installation process.
Close-up of an EZ-Tray for the ICY DOCK FatCage MB155SP-B
చిత్రం 4.3: వివరణాత్మక view of an EZ-Tray, highlighting its design for securing a 3.5" hard drive.

4.3 పవర్ మరియు డేటా కేబుల్‌లను కనెక్ట్ చేయడం

  1. పవర్ కనెక్ట్ చేయండి: Connect three 15-pin SATA power cables from your power supply unit (PSU) to the corresponding 15-pin SATA power ports on the back of the MB155SP-B.
  2. Connect Data: Connect five SATA data cables from your motherboard or RAID controller to the five 7-pin SATA data ports on the back of the MB155SP-B. Ensure each drive bay is connected to a dedicated SATA port on your host system.
వెనుక view of the ICY DOCK FatCage MB155SP-B showing power and data ports
Figure 4.4: Rear panel of the MB155SP-B, indicating the locations of the 15-pin SATA power ports and 7-pin SATA data ports.

5. ఆపరేటింగ్ సూచనలు

5.1 హాట్-స్వాప్ కార్యాచరణ

The MB155SP-B supports SATA hot-swap functionality, allowing you to insert or remove hard drives while the system is running, provided your motherboard or RAID controller also supports this feature. Always ensure proper software ejection procedures are followed before physically removing a drive to prevent data loss.

5.2 LED సూచికలు

Each drive bay features two LED indicators on the front panel:

  • ఆకుపచ్చ LED: Indicates that the hard drive is powered on and ready.
  • అంబర్ LED: Flashes to indicate hard drive activity (data access).
Close-up of the front panel LEDs on the ICY DOCK FatCage MB155SP-B
Figure 5.1: Front panel LEDs showing Green for power and Amber for HDD access.

5.3 ఫ్యాన్ స్పీడ్ సర్దుబాటు

The MB155SP-B includes a 92mm cooling fan with adjustable speed settings. A jumper on the backplane allows you to select between "High," "Low," or "Off" fan speeds to balance cooling performance and noise levels. Refer to Figure 4.4 for the location of the fan speed jumper.

వెనుక view of the ICY DOCK FatCage MB155SP-B showing the cooling fan and PCB
చిత్రం 5.2: వెనుక view of the MB155SP-B, highlighting the 92mm cooling fan and the main PCB.

6. నిర్వహణ

  • ఫ్యాన్ క్లీనింగ్: Periodically inspect the 92mm cooling fan for dust accumulation. If necessary, power down the system, unplug the unit, and carefully clean the fan blades using compressed air or a soft brush. The fan can be removed for thorough cleaning if needed (refer to Figure 6.1).
  • సాధారణ శుభ్రపరచడం: Keep the exterior of the unit clean with a soft, dry cloth. Avoid using liquid cleaners directly on the unit.
  • కేబుల్ కనెక్షన్లు: Ensure all power and data cables remain securely connected to prevent intermittent issues.
Diagram showing removal of the cooling fan from the ICY DOCK FatCage MB155SP-B
Figure 6.1: Illustration of the cooling fan removal process for maintenance.

7. ట్రబుల్షూటింగ్

సమస్యసాధ్యమైన కారణంపరిష్కారం
హార్డ్ డ్రైవ్ గుర్తించబడలేదు.
  • Loose SATA data or power cable.
  • Drive not fully seated in tray.
  • Tray not fully inserted into bay.
  • Motherboard/RAID controller issue.
  • Faulty hard drive.
  • Check and re-seat all SATA data and power cables.
  • Ensure the hard drive is securely mounted in the EZ-Tray.
  • Push the EZ-Tray firmly into the bay until it latches.
  • Test the hard drive directly connected to the motherboard or with another enclosure.
  • Verify motherboard/RAID controller settings and drivers.
No power to hard drives (Green LED off).
  • Loose 15-pin SATA power cable.
  • Power supply unit (PSU) issue.
  • Ensure all 15-pin SATA power cables are securely connected to the MB155SP-B and the PSU.
  • Verify PSU functionality.
Overheating drives.
  • Fan speed set to "Low" or "Off".
  • Dust accumulation on fan.
  • Insufficient case airflow.
  • Adjust the fan speed jumper to "High" (refer to Figure 4.4).
  • Clean the cooling fan (refer to Section 6. Maintenance).
  • Improve overall chassis airflow.

8. స్పెసిఫికేషన్లు

మోడల్ సంఖ్యMB155SP-B
డ్రైవ్ అనుకూలత5 x 3.5" SATA I/II/III Hard Drives
హోస్ట్ ఇంటర్ఫేస్5 x 7-pin SATA Data Ports
పవర్ ఇన్‌పుట్3 x 15-pin SATA Power Connectors
Drive Bay Requirement3 x 5.25" Device Bays
డేటా బదిలీ రేటుUp to 6 Gbps (SATA III)
శీతలీకరణ వ్యవస్థ92mm Cooling Fan with 3-speed control (High/Low/Off)
నిర్మాణ సామగ్రిపూర్తి మెటల్ బాడీ
కొలతలు (LxWxH)5.76 x 7.89 x 4.92 అంగుళాలు (146.3 x 200.4 x 125 మిమీ)
వస్తువు బరువు3.55 పౌండ్లు (1.61 కిలోలు)
అనుకూల పరికరాలుDataCage Classic MB45X, ICYBento MB559 & ICYCube MB561 series trays

9. వారంటీ మరియు మద్దతు

9.1 వారంటీ సమాచారం

The ICY DOCK FatCage MB155SP-B comes with a 3-year limited warranty from the date of purchase. This warranty covers defects in materials and workmanship under normal use. Please retain your proof of purchase for warranty claims. The warranty does not cover damage caused by misuse, accident, modification, or unauthorized repair.

9.2 సాంకేతిక మద్దతు

For technical assistance, troubleshooting, or warranty inquiries, please visit the official ICY DOCK website or contact their customer support department. Contact information can typically be found on the manufacturer's webసైట్.

Webసైట్: www.icydock.com

© 2023 ICY DOCK. All rights reserved. Specifications are subject to change without notice.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.