The DANCO Single-Function Pressure-Balance Temperature Control Cartridge (Model 10664) is designed as a direct replacement for Delta Monitor 13/14 Series faucets (equivalent to Delta OEM #RP46074). This cartridge is essential for controlling both hot and cold water flow and maintaining a consistent, safe water temperature, preventing sudden temperature changes due to pressure fluctuations. It offers an effective and economical solution for repairing leaky faucets without needing to replace the entire fixture.

This product features a durable plastic construction and is compliant with the Reduction of Lead in Drinking Water Act.

సెటప్ మరియు ఇన్‌స్టాలేషన్

Before beginning installation, ensure you have the necessary tools: adjustable wrench, Phillips head screwdriver, flathead screwdriver, and silicone grease (optional, but recommended for seals).

భద్రతా జాగ్రత్తలు:

  • Always turn off the main water supply to your home or the specific bathroom before starting any plumbing work.
  • Cover the drain to prevent small parts from falling into it.

ఇన్‌స్టాలేషన్ దశలు:

  1. కుళాయి హ్యాండిల్‌ను తీసివేయండి: Locate and remove the screw (often hidden under a decorative cap) that secures the faucet handle. Pull the handle off.
  2. ట్రిమ్ మరియు స్లీవ్ తొలగించండి: Carefully remove any decorative trim, escutcheon, or sleeve covering the valve body. This may involve unscrewing additional screws.
  3. రిటైనింగ్ నట్/బోనెట్ నట్ తొలగించండి: Use an adjustable wrench to loosen and remove the large retaining nut (also known as the bonnet nut) that holds the cartridge in place within the valve body.
  4. పాత గుళికను సంగ్రహించండి: Gently pull the old cartridge straight out of the valve body. It may require some wiggling or a pair of channel lock pliers if it's stuck due to mineral buildup. Note its orientation for proper installation of the new cartridge.
  5. కొత్త కార్ట్రిడ్జ్ సిద్ధం చేయండి: Apply a thin layer of silicone grease to the rubber O-rings on the new DANCO cartridge to ensure a smooth fit and better seal.
  6. కొత్త కార్ట్రిడ్జ్ చొప్పించండి: Align the new cartridge with the notches or alignment tabs inside the valve body. Push it firmly into place. Ensure it is fully seated. If it doesn't go all the way in by hand, the retaining nut will help push it in when tightened.
  7. సెక్యూర్ కార్ట్రిడ్జ్: Reinstall and hand-tighten the retaining nut over the cartridge. Then, use an adjustable wrench to tighten it securely, but do not overtighten.
  8. కుళాయిని తిరిగి అమర్చండి: Replace the sleeve, trim, and faucet handle in reverse order of removal. Secure the handle screw.
  9. నీటి సరఫరాను పునరుద్ధరించండి: ప్రధాన నీటి సరఫరాను నెమ్మదిగా తిరిగి ప్రారంభించండి.
  10. పరీక్ష కుళాయి: Check for leaks and proper hot/cold water flow and temperature control.
DANCO Single-Function Pressure-Balance Temperature Control Cartridge, front view

మూర్తి 1: ముందు view of the DANCO cartridge, showing its overall structure and connection points.

DANCO Single-Function Pressure-Balance Temperature Control Cartridge, top view with hot/cold markings

మూర్తి 2: టాప్ view of the cartridge, indicating 'HOTTER' and 'COLDER' settings for temperature adjustment and proper orientation during installation.

ఆపరేటింగ్ సూచనలు

This cartridge provides single-function pressure-balance temperature control. Once installed, the faucet handle will allow you to control both water flow and temperature. Rotating the handle typically adjusts the temperature from cold to hot, while pulling it out or pushing it in controls the water volume.

Temperature Limit Stop: Your faucet's valve body may have an adjustable temperature limit stop. If the maximum hot water temperature is too low or too high after installation, consult your faucet's original manual or a plumbing guide for instructions on how to adjust this limit stop. This adjustment is usually made on the valve body itself, not the cartridge, and prevents scalding by limiting the maximum hot water output.

నిర్వహణ

To ensure the longevity and optimal performance of your DANCO cartridge, consider the following maintenance tips:

  • రెగ్యులర్ క్లీనింగ్: Periodically clean the exterior of your faucet. Avoid harsh abrasive cleaners that can damage the finish.
  • లీక్‌ల కోసం తనిఖీ చేయండి: Regularly inspect your faucet for any signs of dripping or leaks. Addressing minor leaks promptly can prevent larger issues.
  • సరళత: If you notice the handle becoming stiff or difficult to turn, it may indicate that the O-rings on the cartridge need re-lubrication. Turn off the water supply, remove the cartridge as per installation steps, apply fresh silicone grease to the O-rings, and reinstall.
  • నీటి నాణ్యత: In areas with hard water, mineral deposits can build up on internal components. If flow or temperature control is affected, the cartridge may need to be removed and cleaned of mineral buildup.

ట్రబుల్షూటింగ్

If you encounter issues with your faucet after installing the DANCO cartridge, refer to the common problems and solutions below:

సమస్యసాధ్యమైన కారణంపరిష్కారం
Faucet is dripping or leaking
  • Cartridge not fully seated
  • దెబ్బతిన్న O-రింగులు లేదా సీల్స్
  • Debris in the cartridge
  • Ensure cartridge is pushed all the way in and retaining nut is tight.
  • Inspect O-rings for damage; replace if necessary. Apply silicone grease.
  • Remove and clean the cartridge to clear any debris.
వేడి లేదా చల్లని నీరు లేదు
  • Water supply valves are off
  • Cartridge installed incorrectly (e.g., reversed)
  • Blocked water lines
  • Check that hot and cold water supply valves are fully open.
  • Verify cartridge orientation (refer to Figure 2).
  • Inspect water lines for clogs or kinks.
తక్కువ నీటి ఒత్తిడి
  • ఏరేటర్ మూసుకుపోయింది
  • Partially closed supply valves
  • Debris in the cartridge
  • Remove and clean the faucet aerator.
  • నీటి సరఫరా కవాటాలు పూర్తిగా తెరిచి ఉన్నాయని నిర్ధారించుకోండి.
  • Remove and clean the cartridge.
Temperature is too hot/cold or inconsistent
  • Temperature limit stop needs adjustment
  • Pressure imbalance
  • Adjust the temperature limit stop on the faucet valve body (consult your faucet's manual).
  • Ensure both hot and cold water supplies have adequate and balanced pressure.

స్పెసిఫికేషన్లు

గుణంవివరాలు
బ్రాండ్డాన్కో
మోడల్ సంఖ్య10664
పార్ట్ నంబర్9D00010664
మెటీరియల్ప్లాస్టిక్
రంగుతెలుపు
వస్తువు బరువు2.82 ఔన్సులు
ఉత్పత్తి కొలతలు (L x W x H)2.1 x 2.6 x 7.5 అంగుళాలు
వాల్వ్ రకంCartridge (Pressure-Balance)
Number of Handles Supported1 (Single-Function)
ఇన్లెట్ కనెక్షన్ పరిమాణం1.91 అంగుళాలు
అవుట్‌లెట్ కనెక్షన్ పరిమాణం1.91 అంగుళాలు
చేర్చబడిన భాగాలు(1) cartridge
అనుకూలతDelta Monitor 13/14 Series (Replaces Delta OEM #RP46074)

వారంటీ మరియు మద్దతు

This DANCO cartridge comes with a పరిమిత 1 సంవత్సరం వారంటీ from the manufacturer. For specific warranty claims or detailed support, please contact Danco customer service directly.

For additional information or a printable version of the user guide, you may refer to the official PDF document: DANCO User Guide (PDF).

© 2023 Danco. All rights reserved.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.