1. పరిచయం
This manual provides detailed instructions for the deleyCON Mechanical Timer Switch, designed to automate the on/off cycles of various indoor electrical devices. Please read this manual carefully before using the product to ensure safe and efficient operation.
2. భద్రతా సూచనలు
- This timer is designed for ఇండోర్ ఉపయోగం మాత్రమే. Do not expose it to moisture or outdoor conditions.
- Ensure the connected device's power consumption does not exceed the timer's maximum load of 3500 W (16 ఎ).
- Always disconnect the timer from the power outlet before cleaning or if it is not in use for an extended period.
- Do not connect multiple timers in series.
- The product features increased touch protection for safety.
- If the timer makes an audible mechanical clicking sound, this is normal operation for the switching segments.
3. ఉత్పత్తి ముగిసిందిview
The deleyCON Mechanical Timer Switch features a robust design for reliable operation. Key components include the 24-hour dial with 15-minute segments and a manual override switch.

మూర్తి 3.1: ముందు view of the deleyCON Mechanical Timer Switch, showing the central socket and the 24-hour rotating dial.

మూర్తి 3.2: వైపు view of the timer, highlighting the manual override switch (I/O/Timer symbol) and the textured edge of the dial for easy rotation.

మూర్తి 3.3: వెనుకకు view of the timer, displaying technical specifications such as voltage, frequency, maximum load, and safety certifications.
4. సెటప్ సూచనలు
Follow these steps to configure your deleyCON Mechanical Timer Switch:
- Prepare the Timer Segments: The timer's central dial is surrounded by small pins, each representing a 15-minute interval. When new, all pins are typically pushed down (ON). To set a program, first pull అన్ని pins upwards (OFF position) around the entire 24-hour dial.
- Set the ON/OFF Periods: Push down the pins corresponding to the time periods you want the connected device to be ON. Each pushed-down pin activates the power for 15 minutes. For example, to have power from 7:00 AM to 2:00 PM, push down all pins between the '7' and '14' marks on the dial. If you need power for only one hour (e.g., 9:00 PM to 10:00 PM), push down the four pins within that hour segment.
- ప్రస్తుత సమయాన్ని సెట్ చేయండి: Rotate the entire dial clockwise until the small arrow (usually located in the inner circle, pointing towards the numbers 1-24) aligns with the current time. Be precise, as this arrow can be small and blend with the background.
- శక్తికి కనెక్ట్ చేయండి: Plug the timer into a standard indoor wall socket.
- పరికరాన్ని కనెక్ట్ చేయండి: Plug the device you wish to control into the timer's socket.

మూర్తి 4.1: A hand demonstrating how to adjust the 24-hour dial and push down the 15-minute segments to set the desired ON times.
5. ఆపరేటింగ్ సూచనలు
The deleyCON Mechanical Timer Switch offers both programmed and manual operation modes.
5.1 మాన్యువల్ ఓవర్రైడ్ స్విచ్
On the right side of the timer, there is a sliding switch with three positions:
- 'I' (ON): When the switch is in the 'I' (upwards) position, the connected device will receive continuous power, regardless of the dial's programmed settings. This is for constant ON operation.
- Timer Symbol (Middle): When the switch is in the middle position (indicated by a clock or timer symbol), the timer will operate according to the ON/OFF periods you have set on the dial.
- 'O' (OFF): When the switch is in the 'O' (downwards) position, the connected device will remain OFF, regardless of the dial's programmed settings. This is for constant OFF operation.
Always ensure the switch is in the టైమర్ చిహ్నం position for automatic operation.

మూర్తి 5.1: The deleyCON timer in use, connected to a lamp, illustrating how it controls power to an appliance based on its settings.
6. నిర్వహణ
- To clean the timer, unplug it from the wall socket. Use a soft, dry cloth. Do not use liquid cleaners or immerse the timer in water.
- Regularly check the timer and its connected cables for any signs of damage. If damage is found, discontinue use and replace the unit.
- టైమర్ను ఉపయోగించనప్పుడు పొడి, చల్లని ప్రదేశంలో నిల్వ చేయండి.
7. ట్రబుల్షూటింగ్
- Timer is not switching ON/OFF:
- Check if the manual override switch is in the 'Timer Symbol' position.
- Verify that the pins for the desired ON period are pushed down.
- డయల్పై ప్రస్తుత సమయం సరిగ్గా సెట్ చేయబడిందని నిర్ధారించుకోండి.
- గోడ సాకెట్కు విద్యుత్ సరఫరా అందుతుందో లేదో తనిఖీ చేయండి.
- Timer is making a clicking sound: This is normal for mechanical timers as the internal mechanism operates the switching segments. It does not indicate a fault.
- Connected device is not receiving power:
- Ensure the device itself is switched ON.
- Test the device by plugging it directly into a wall socket to confirm it is functional.
8. స్పెసిఫికేషన్లు

మూర్తి 8.1: Visual representation of the timer's dimensions: 8cm width, 8cm height, and 6cm depth.
| ఫీచర్ | వివరాలు |
|---|---|
| మోడల్ సంఖ్య | MK2636 |
| బ్రాండ్ | deleyCON |
| రంగు | తెలుపు |
| మెటీరియల్ | ప్లాస్టిక్ (కున్స్ట్స్టాఫ్) |
| ఇన్పుట్ వాల్యూమ్tage | 220 - 240 V AC, 50 Hz |
| గరిష్ట లోడ్ | 16 ఎ, 3500 డబ్ల్యూ |
| కనీస మార్పిడి సమయం | 15 నిమిషాల |
| Circuits per Day | 96 (4 circuits per hour) |
| రక్షణ తరగతి | IP20 (ఇండోర్ ఉపయోగం మాత్రమే) |
| ఉత్పత్తి కొలతలు (D x W x H) | 6 x 8 x 8 సెం.మీ |
| వస్తువు బరువు | 132 గ్రాములు |
9. వారంటీ మరియు మద్దతు
For warranty information or technical support, please contact deleyCON customer service. Refer to your purchase documentation for specific warranty terms and contact details.
తయారీదారు: deleyCON