1. పరిచయం
This manual provides detailed instructions for the installation, operation, and maintenance of the EVURU Digital Single Phase Energy Meter. This device is designed to measure active energy (kWh), voltage, current, and power consumption in single-phase AC circuits. Please read this manual thoroughly before installation and use to ensure safe and correct operation.
2. భద్రతా సమాచారం
- సంస్థాపన మరియు నిర్వహణ అర్హత కలిగిన సిబ్బంది మాత్రమే నిర్వహించాలి.
- Ensure the power supply is disconnected before any installation or wiring work.
- అధిక తేమ, దుమ్ము లేదా తినివేయు వాయువులు ఉన్న వాతావరణాలలో మీటర్ను ఆపరేట్ చేయవద్దు.
- Verify all connections are secure and correct according to the wiring diagrams to prevent damage to the meter or electrical system.
- మీటర్ ఇండోర్ ఉపయోగం కోసం మాత్రమే రూపొందించబడింది.
3. ఉత్పత్తి ముగిసిందిview మరియు ఫీచర్లు
The EVURU Digital Single Phase Energy Meter is a compact device for DIN rail installation, offering precise measurement of electrical parameters. Key features include:
- LCD display with backlight for clear readings.
- Measures total Energy (kWh), temporary Energy (kWh), real Voltage (V), real Current (A), and real Power (W).
- Pulse LED indicator for active energy measurement.
- 35mm DIN rail mounting.
- Temporary kWh can be reset to zero. Total kWh is non-resettable.

చిత్రం 1: పైగాview of DDS662, DDS667, and DDS668 models.

Figure 2: Feature comparison table for DDS662, DDS667, and DDS668 models.
4. స్పెసిఫికేషన్లు
| పరామితి | విలువ |
|---|---|
| గరిష్ట కరెంట్ | 80A |
| పల్స్ ఫ్రీక్వెన్సీ | 1000imp / kWh |
| నామమాత్రపు సంtage | 220V AC |
| సంస్థాపన | 35 ఎంఎం డిఎన్ రైల్ |
| ప్రదర్శన రకం | బ్యాక్లైట్తో LCD |
| కొలిచిన పారామితులు | Total kWh, Temporary kWh, Voltagఇ, కరెంట్, పవర్ |
| Temporary kWh Reset | Yes (hold button for 6 seconds) |
| Total kWh Reset | నం |
| Wiring Modes | Upper input lower output, Lower input upper output |
| వస్తువు బరువు | 0.035 ఔన్సులు (సుమారు 1 గ్రాము) |
5. ఇన్స్టాలేషన్ (సెటప్)
5.1 కొలతలు
Before installation, ensure adequate space for the meter. The dimensions are suitable for standard DIN rail enclosures.

Figure 3: Meter dimensions (example shown for DDS668).
5.2 DIN రైలు మౌంటు
The meter is designed for 35mm DIN rail installation. Simply clip the meter onto the DIN rail in your electrical panel.
5.3 వైరింగ్ రేఖాచిత్రాలు
Ensure all power is OFF before proceeding with wiring. Connect the meter according to the appropriate diagram for your model and desired wiring mode.
5.3.1 DDS662 Wiring
The DDS662 model typically uses a direct connection for single-phase two-wire systems.

Figure 4: Wiring diagram for DDS662 model.
5.3.2 DDS667 Wiring
The DDS667 model can be integrated with circuit breakers for protection.

Figure 5: Wiring diagram for DDS667 model, showing integration with circuit breakers.
5.3.3 DDS668 Wiring Modes
The DDS668 model supports two wiring configurations: upper input/lower output and lower input/upper output.

Figure 6: Wiring diagrams for DDS668 model, illustrating upper input/lower output and lower input/upper output modes.
6. ఆపరేషన్
6.1 పవర్ ఆన్
Once correctly wired and mounted, restore power to the circuit. The LCD display will illuminate, showing the current readings.
6.2 Reading Displayed Values
The meter cycles through various parameters on its LCD display. You can manually press the button (if available on your model, e.g., DDS667, DDS668) to cycle through:
- మొత్తం శక్తి (kWh)
- Temporary Energy (kWh)
- Real Voltagఇ (వి)
- Real Current (A)
- రియల్ పవర్ (W)
The pulse LED will flash to indicate active energy measurement.
6.3 Resetting Temporary kWh
To reset the temporary kWh reading to zero, press and hold the button on the front of the meter for approximately 6 seconds. Note that the total kWh reading cannot be reset.
7. నిర్వహణ
The EVURU Digital Single Phase Energy Meter requires minimal maintenance.
- Keep the meter clean and free from dust. Use a soft, dry cloth for cleaning.
- రాపిడి క్లీనర్లు లేదా ద్రావకాలు ఉపయోగించవద్దు.
- Regularly inspect wiring connections for tightness and signs of wear or damage.
- Ensure the operating environment remains within specified conditions (temperature, humidity).
8. ట్రబుల్షూటింగ్
- No Display / Meter Not Powering On:
- Check the power supply to the circuit.
- రేఖాచిత్రాల ప్రకారం అన్ని వైరింగ్ కనెక్షన్లు సురక్షితంగా మరియు సరిగ్గా ఉన్నాయని ధృవీకరించండి.
- సరికాని రీడింగ్లు:
- Ensure the meter is correctly wired for the load. Incorrect wiring can lead to inaccurate measurements.
- వాల్యూమ్ని నిర్ధారించండిtage and current are within the meter's specified range (e.g., 220V AC, max 80A).
- Temporary kWh Not Resetting:
- Ensure you are holding the reset button for the full 6 seconds.
- Note that the total kWh cannot be reset.
- Pulse LED Not Flashing:
- Verify there is an active load connected and drawing power through the meter.
- Check wiring for proper current flow.
9. వారంటీ మరియు మద్దతు
వారంటీ సమాచారం లేదా సాంకేతిక మద్దతు కోసం, దయచేసి ఉత్పత్తి ప్యాకేజింగ్ను చూడండి లేదా మీ రిటైలర్ను సంప్రదించండి. కొనుగోలు రుజువుగా మీ కొనుగోలు రసీదును ఉంచండి.