EVURU 2W-25B EPDM

EVURU 2/2 DN25 SS Electric Water Valve Instruction Manual

Model: 2W-25B EPDM

1. పరిచయం

This manual provides essential information for the safe and efficient installation, operation, and maintenance of your EVURU 2/2 DN25 Stainless Steel Electric Water Valve. This valve is a normally closed, direct-acting solenoid valve designed for controlling the flow of water, gas, or liquid in various applications.

Please read this manual thoroughly before installation and operation to ensure proper function and to prevent damage or injury. Keep this manual for future reference.

2. భద్రతా సమాచారం

హెచ్చరిక: ఈ భద్రతా సూచనలను పాటించడంలో విఫలమైతే ఆస్తి నష్టం, తీవ్రమైన గాయం లేదా మరణం సంభవించవచ్చు.

  • Always disconnect power before installing, servicing, or cleaning the valve.
  • వాల్యూమ్ అని నిర్ధారించుకోండిtage supply matches the valve's specified voltage (e.g., AC220V, DC12V). Incorrect voltage can damage the valve or cause electrical hazards.
  • స్థానిక ఎలక్ట్రికల్ మరియు ప్లంబింగ్ కోడ్‌లకు అనుగుణంగా అర్హత కలిగిన సిబ్బంది ద్వారా ఇన్‌స్టాలేషన్ నిర్వహించాలి.
  • Do not exceed the maximum working pressure specified for the valve.
  • Ensure the media (water, gas, liquid) and its temperature are within the valve's specified limits.
  • సంస్థాపన మరియు నిర్వహణ సమయంలో తగిన వ్యక్తిగత రక్షణ పరికరాలు (PPE) ధరించండి.
  • Avoid exposing the valve to corrosive environments or extreme temperatures outside its operating range.

3. ఉత్పత్తి ముగిసిందిview

The EVURU 2/2 DN25 SS Electric Water Valve is a robust solenoid valve constructed from Stainless Steel 304, designed for reliable flow control. It features a 1-inch pipe size (DN25) and is available with BSP or NPT threads. The valve operates as normally closed, meaning it remains closed when de-energized and opens when energized.

Assembled EVURU 2/2 DN25 SS Electric Water Valve with black solenoid coil and red wires.

Figure 1: Assembled EVURU 2/2 DN25 SS Electric Water Valve. This image shows the complete valve unit, including the stainless steel body, the black solenoid coil, and the red electrical wires.

4. సెటప్ మరియు ఇన్‌స్టాలేషన్

4.1 ప్రీ-ఇన్‌స్టాలేషన్ తనిఖీలు

  • Verify that the valve specifications (voltage, pressure, media, temperature) match your application requirements.
  • Inspect the valve for any visible damage from shipping.
  • Ensure the piping system is clean and free of debris that could obstruct valve operation.

4.2 మెకానికల్ ఇన్‌స్టాలేషన్

  1. Turn off the main power supply and shut off the fluid flow to the installation area.
  2. Identify the inlet and outlet ports on the valve body. Flow direction is typically indicated by an arrow on the valve body.
  3. Apply appropriate thread sealant (e.g., PTFE tape or pipe dope) to the pipe threads.
  4. Thread the valve onto the pipes, ensuring a tight, leak-free connection. Do not overtighten.
  5. Mount the valve in a position that allows for easy access for maintenance and inspection. The solenoid coil should ideally be in an upright position to prevent accumulation of debris and ensure proper operation.

4.3 ఎలక్ట్రికల్ కనెక్షన్

  1. విద్యుత్ సరఫరా డిస్‌కనెక్ట్ చేయబడిందని నిర్ధారించుకోండి.
  2. Connect the valve's electrical wires to the appropriate power source. Refer to the voltage specified on the solenoid coil.
  3. షార్ట్ సర్క్యూట్లు లేదా విద్యుత్ ప్రమాదాలను నివారించడానికి అన్ని విద్యుత్ కనెక్షన్లు సురక్షితంగా మరియు సరిగ్గా ఇన్సులేట్ చేయబడిందని నిర్ధారించుకోండి.
  4. If applicable, connect the ground wire according to local electrical codes.
Disassembled EVURU 2/2 DN25 SS Electric Water Valve showing body, coil, and nut.

Figure 2: Disassembled EVURU 2/2 DN25 SS Electric Water Valve components. This image displays the main stainless steel valve body, the separate solenoid coil, and the retaining nut, illustrating how the coil attaches to the valve stem.

5. ఆపరేటింగ్ సూచనలు

The EVURU 2/2 DN25 SS Electric Water Valve is a normally closed (N/C) valve, meaning it is closed by default when no power is applied to the solenoid coil.

  1. To Open the Valve: Apply the specified electrical voltage to the solenoid coil. The coil will energize, lifting the plunger and opening the valve, allowing fluid to flow.
  2. To Close the Valve: Disconnect the electrical voltage from the solenoid coil. The coil will de-energize, and the plunger will return to its closed position, stopping the fluid flow.

Ensure that the system pressure and fluid temperature remain within the valve's specified operating limits during operation.

6. నిర్వహణ

Regular maintenance helps ensure the longevity and reliable operation of your valve.

  • ఆవర్తన తనిఖీ: Regularly check for any signs of leaks around the valve body and connections. Inspect the electrical wiring for damage or loose connections.
  • శుభ్రపరచడం: If the valve is operating in an environment with particulate matter, periodic cleaning of the internal components may be necessary. Always disconnect power and depressurize the system before disassembling the valve.
  • సీల్ భర్తీ: Over time, the EPDM seals may wear out. If leaks occur or the valve fails to seal properly, the seals may need to be replaced. Refer to Figure 2 for component identification.
  • Coil Inspection: Ensure the solenoid coil is free from excessive heat, moisture, or physical damage.

Note: For complex repairs or internal component replacement, it is recommended to consult a qualified technician or the manufacturer.

7. ట్రబుల్షూటింగ్

సమస్య సాధ్యమైన కారణం పరిష్కారం
శక్తినిచ్చినప్పుడు వాల్వ్ తెరుచుకోదు.
  • No power to the coil.
  • సరికాని వాల్యూమ్tage.
  • Coil damaged or burnt out.
  • Debris obstructing plunger.
  • Excessive pressure differential.
  • విద్యుత్ సరఫరా మరియు కనెక్షన్లను తనిఖీ చేయండి.
  • వాల్యూమ్‌ను ధృవీకరించండిtage matches valve specification.
  • కాయిల్ భర్తీ చేయండి.
  • Disassemble and clean valve internals.
  • Ensure operating pressure is within limits.
విద్యుత్ సరఫరా నిలిచిపోయినప్పుడు వాల్వ్ మూసుకుపోదు.
  • Debris lodged in valve seat.
  • Damaged or worn seal.
  • Spring failure.
  • Disassemble and clean valve internals.
  • సీల్స్ స్థానంలో.
  • Replace valve or internal components.
Leakage from valve body or connections.
  • Loose pipe connections.
  • దెబ్బతిన్న లేదా అరిగిపోయిన సీల్స్.
  • పగిలిన వాల్వ్ బాడీ.
  • Tighten connections, reapply thread sealant.
  • సీల్స్ స్థానంలో.
  • వాల్వ్‌ను భర్తీ చేయండి.
కాయిల్ వేడెక్కడం.
  • సరికాని వాల్యూమ్tage.
  • Continuous operation beyond duty cycle (if applicable).
  • Internal short circuit.
  • వాల్యూమ్‌ను ధృవీకరించండిtage.
  • Ensure valve is suitable for continuous duty or adjust operation.
  • కాయిల్ భర్తీ చేయండి.

8. స్పెసిఫికేషన్లు

మోడల్ 2W-25B EPDM
పైపు పరిమాణం 1 inch (DN25)
థ్రెడ్ రకం BSP, NPT
మీడియా Water, Gas, Liquid
టైప్ చేయండి Normally Closed (N/C), Direct Acting
Working Pressure (Water, Air) 0-10 బార్
Working Pressure (Oil) 0-7 బార్
వాల్యూమ్tagఇ ఎంపికలు AC240V, AC220V, AC120V, AC110V, AC24V, DC24V, DC12V (±10% tolerance)
మెటీరియల్ స్టెయిన్‌లెస్ స్టీల్ 304
సీల్ మెటీరియల్ EPDM
Medium Temperature (EPDM) -5 నుండి 120 °C (23 నుండి 248 °F)
వస్తువు బరువు 1 Grams (Note: This value seems unusually low and may be a placeholder. Refer to actual product for accurate weight.)

9. వారంటీ సమాచారం

Specific warranty details for the EVURU 2/2 DN25 SS Electric Water Valve are not provided in this manual. For information regarding product warranty, please refer to the purchase documentation, contact your retailer, or visit the official EVURU webసైట్.

10. కస్టమర్ మద్దతు

If you encounter any issues or have questions not covered in this manual, please contact your product supplier or the manufacturer's customer support. When contacting support, please have your product model number (2W-25B EPDM) and purchase details readily available.

© 2023 EVURU. All rights reserved.