1. పరిచయం
This manual provides essential information for the safe and effective operation of your Extracorporeal Radial Shock Wave Therapy Machine. This device is designed to activate cellular tissue self-repair and bone damage repair by improving blood circulation, offering a non-invasive solution for various pain conditions and erectile dysfunction (ED).
దయచేసి ప్రారంభ ఉపయోగం ముందు ఈ మాన్యువల్ను పూర్తిగా చదవండి మరియు భవిష్యత్తు సూచన కోసం దీన్ని ఉంచండి.
2. భద్రతా సమాచారం
ముఖ్యమైన భద్రతా సూచనలు:
- This device is intended for use by trained professionals or under the guidance of a healthcare provider.
- Do not use this device on open wounds, inflamed skin, or areas with active infections.
- Avoid use on pregnant women, individuals with pacemakers, blood clotting disorders, or malignant tumors.
- పరికరాన్ని నీరు మరియు తీవ్రమైన ఉష్ణోగ్రతల నుండి దూరంగా ఉంచండి.
- Ensure the power supply matches the device specifications (AC110V-AC220V).
- Always disconnect the power cord before cleaning or maintenance.
- Do not attempt to modify or repair the device yourself. Contact qualified service personnel.
- ఆహార పదార్ధాలకు సంబంధించిన ప్రకటనలు FDAచే మూల్యాంకనం చేయబడలేదు మరియు ఏదైనా వ్యాధి లేదా ఆరోగ్య పరిస్థితిని నిర్ధారించడానికి, చికిత్స చేయడానికి, నయం చేయడానికి లేదా నిరోధించడానికి ఉద్దేశించబడలేదు.
3. ప్యాకేజీ విషయాలు
అన్ప్యాక్ చేసిన తర్వాత అన్ని వస్తువులు ఉన్నాయని మరియు పాడవకుండా ఉన్నాయని ధృవీకరించండి:
- 1 x Host Unit
- 7 x Massage Heads (Probes)
- 1 x Handle with Wire
Image 3.1: Main components of the shock wave therapy machine, showing the host unit, the applicator handle, and several interchangeable massage heads.
4. సెటప్
- Place the host unit on a stable, flat surface.
- Connect the handle with the wire to the designated port on the host unit. Ensure a secure connection.
- Select the appropriate massage head (probe) for the intended treatment area and attach it firmly to the handle.
- Connect the power cord to the host unit and then plug it into a suitable electrical outlet.
- Press the power button on the host unit to turn on the device. The display screen should illuminate.
Image 4.1: The Extracorporeal Massage Machine handle, which connects to the main unit for operation.
5. ఆపరేటింగ్ సూచనలు
5.1 సాధారణ ఆపరేషన్
- After powering on, use the control panel to adjust the frequency and energy settings according to the treatment requirements. The device offers 16 frequency gears and 25 energy gears.
- Apply a coupling gel to the skin over the treatment area to ensure efficient transmission of shock waves.
- Place the selected massage head firmly against the skin in the treatment area.
- Initiate the treatment as per the recommended protocol for the specific condition.
- The device operates on a physics mechanism, conducting mechanical wave pulse pressure into shock waves to achieve the desired therapeutic effect.
5.2 అప్లికేషన్లు
The shock wave therapy machine is suitable for various applications, including:
- నొప్పి ఉపశమనం: Effective for cervical pain, back pain, shoulder pain, lumbar acid, plantar fasciitis, and heel pain. It improves microcirculation and metabolism in affected areas.
- Physical Therapy and Rehabilitation: Aids in recovery from sports injuries and general rehabilitation.
- ED Treatment: Stimulates tissue cell regeneration and promotes penile blood vessel proliferation for improved erectile function.
- Soft Tissue Treatment: Widely applicable to various soft tissue conditions.
Image 5.1: Illustrates various body areas suitable for shockwave therapy, including common pain points and areas for ED treatment.
5.3 ED Treatment Specifics
- This therapy addresses the cause of ED by increasing blood flow and triggering natural repair mechanisms.
- It is non-invasive, generally painless, and offers clinically proven long-term results.
- Each treatment session typically takes about 10 minutes.
Image 5.2: Detailed diagram explaining the application of Extracorporeal Shock Wave Therapy (ESWT) for ED, focusing on vascular improvement.
5.4 Deep Layer Therapy
The device utilizes high-frequency massage modes and intelligent adjustment of massage intensity to penetrate deep into the fascia layer, promoting healing and pain relief.
Image 5.3: Illustration of shockwave penetration into deep tissue layers for physiotherapy and therapy.
6. నిర్వహణ
- శుభ్రపరచడం: After each use, wipe the massage heads and the handle with a soft, damp cloth. Use a mild disinfectant if necessary. Ensure the device is unplugged before cleaning.
- నిల్వ: పరికరాన్ని చల్లని, పొడి ప్రదేశంలో, ప్రత్యక్ష సూర్యకాంతి మరియు తీవ్రమైన ఉష్ణోగ్రతలకు దూరంగా నిల్వ చేయండి.
- తనిఖీ: Regularly inspect the power cord, handle, and massage heads for any signs of wear or damage. Do not use the device if any components are damaged.
7. ట్రబుల్షూటింగ్
మీ పరికరంలో సమస్యలు ఎదురైతే, కింది సాధారణ ట్రబుల్షూటింగ్ దశలను చూడండి:
- పరికరం ఆన్ చేయడం లేదు:
- Check if the power cord is securely plugged into both the device and the electrical outlet.
- పవర్ అవుట్లెట్ పని చేస్తుందని నిర్ధారించుకోండి.
- No Shock Wave Output:
- Verify that the handle is correctly connected to the host unit.
- Ensure a massage head is properly attached to the handle.
- Check the energy and frequency settings on the control panel.
- అసాధారణ శబ్దం లేదా కంపనం:
- Turn off the device immediately and inspect for any loose parts or damage.
- సమస్య కొనసాగితే, వినియోగాన్ని ఆపివేసి, కస్టమర్ సపోర్ట్ని సంప్రదించండి.
For issues not covered here, please contact the manufacturer or seller for assistance.
8. స్పెసిఫికేషన్లు
| ఉత్పత్తి పేరు | Extracorporeal Shock Wave Therapy Machine |
| మోడల్ | B0F2MBZMG1 |
| ఫ్రీక్వెన్సీ | 50HZ/60HZ |
| వాల్యూమ్tage | AC110V-AC220V |
| Working Probes | 7 |
| రేట్ చేయబడిన శక్తి | 220WMAX |
| ప్రస్తుత | 3A MAX |
| గరిష్ట శక్తి | 250 ఎం.జె. |
| Energy Gears | 25 |
| Frequency Gears | 16 |
| స్థూల బరువు | 3.8కి.గ్రా |
| ప్యాకింగ్ పరిమాణం | 360×240×200మి.మీ |
| మొదటి తేదీ అందుబాటులో ఉంది | మార్చి 27, 2025 |
| తయారీదారు | సాధారణమైనది |
9. వారంటీ మరియు మద్దతు
For warranty information, please refer to the documentation provided at the time of purchase or contact the seller directly. Support for this product is typically provided by the retailer or manufacturer. Please retain your proof of purchase for any warranty claims or technical assistance.
For further inquiries, please contact your point of purchase or the manufacturer, Generic.