SASKATE SASKATEg1md94kzr8

SASKATE 3.7V Lithium Battery Over Discharge Module User Manual

Model: SASKATEg1md94kzr8

1. పరిచయం

This manual provides detailed instructions for the SASKATE 3.7V Lithium Battery Over Discharge Module. This module is designed to protect 3.7V lithium batteries from overcharge and over-discharge conditions, ensuring the longevity and safety of your battery-powered equipment. It also offers short circuit and overcurrent protection.

టాప్ view of the SASKATE 3.7V Lithium Battery Over Discharge Module, showing the green circuit board with integrated circuits and connection pads.

Figure 1: SASKATE 3.7V Lithium Battery Over Discharge Module (Top View)

The image displays the compact green circuit board of the module, featuring several surface-mounted components including integrated circuits and resistors. Four circular connection pads are visible on one side, and two larger rectangular pads on the other.

2. సెటప్ మరియు వైరింగ్

Proper wiring is crucial for the correct operation and protection provided by the module. Follow the instructions below carefully.

2.1 వైరింగ్ రేఖాచిత్రం మరియు కనెక్షన్లు

  • B-: Connect to the negative terminal of the battery.
  • B+: Connect to the positive terminal of the battery.
  • P+: Connect the positive terminal of the charger or load.
  • P-: Connect the negative terminal of the charger or load.
వెనుకకు view of the SASKATE 3.7V Lithium Battery Over Discharge Module, showing labeled connection pads B-, B+, P+, P-.

Figure 2: Module Back View with Wiring Labels

This image shows the reverse side of the module, which is a plain green circuit board. Clearly labeled connection points (B-, B+, P+, P-) are visible, indicating where the battery, charger, and load should be connected.

2.2 ప్రారంభ క్రియాశీలత

ముఖ్యమైన నోటీసు: Please activate the board during the second connection. Otherwise, there may be no voltage output. This typically involves connecting the battery and then applying a charge for the first time to initialize the protection circuit.

3. ఆపరేటింగ్ సూత్రాలు

The SASKATE Over Discharge Module continuously monitors the voltage of the connected 3.7V lithium battery.

  • అధిక ఛార్జ్ రక్షణ: బ్యాటరీ వాల్యూమ్ ఉన్నప్పుడుtage reaches the overcharge detection voltage (4.28±0.05V), the module will stop charging to prevent overcharging. Charging will resume when the voltage drops to the overcharge release voltage (4.26±0.05V).
  • అధిక ఉత్సర్గ రక్షణ: బ్యాటరీ వాల్యూమ్ అయితేtage drops to the over-discharge detection voltage (2.5±0.1V), the module will cut off the load to prevent deep discharge, which can damage the battery.
  • ఓవర్ కరెంట్ రక్షణ: The module provides protection against excessive current draw, typically activating between 1-3A with an overcurrent release at 3.2±0.2A.
  • షార్ట్ సర్క్యూట్ రక్షణ: In the event of a short circuit, the module will immediately cut off the output to protect the battery and connected devices.
SASKATE module with text overlay highlighting its protection features: 3.7V lithium battery application, overcharge, overdischarge, short circuit, and overcurrent protection.

Figure 3: Module Features Overview

This image shows the module with an overlay of text summarizing its key features: "Application field: 3.7V lithium battery 18650", "Overcharge protection, overdischarge protection", and "Short circuit protection, over current protection".

4. నిర్వహణ

The SASKATE Over Discharge Module is designed for durability and requires minimal maintenance.

  • నిర్వహణ: Handle the module with care to avoid damaging the electronic components. Avoid bending or applying excessive force.
  • పర్యావరణం: Keep the module in a dry environment, away from moisture, dust, and extreme temperatures.
  • శుభ్రపరచడం: అవసరమైతే, మృదువైన, పొడి గుడ్డతో మాడ్యూల్‌ను సున్నితంగా శుభ్రం చేయండి. ద్రవ క్లీనర్‌లు లేదా ద్రావకాలను ఉపయోగించవద్దు.
  • తనిఖీ: వైరింగ్ కనెక్షన్లు సురక్షితంగా మరియు తుప్పు పట్టకుండా ఉన్నాయని నిర్ధారించుకోవడానికి వాటిని కాలానుగుణంగా తనిఖీ చేయండి.

5. ట్రబుల్షూటింగ్

If you encounter issues with your SASKATE Over Discharge Module, refer to the following common problems and solutions.

సమస్యసాధ్యమైన కారణంపరిష్కారం
వాల్యూమ్ లేదుtage output from P+ / P- terminals.Module not activated after initial connection.Ensure the board is activated during the second connection. This typically means connecting the battery and then applying a charge to the P+ / P- terminals to initialize the protection circuit.
Battery not charging or discharging.Protection circuit activated (overcharge/over-discharge/overcurrent).బ్యాటరీ వాల్యూమ్‌ని తనిఖీ చేయండిtage. If too high or too low, the module is functioning as intended. If overcurrent, reduce load. Ensure wiring is correct.
Module not functioning as expected.Incorrect wiring or damaged module.Double-check all wiring connections against the diagram. If wiring is correct, the module may be faulty and require replacement.

6. స్పెసిఫికేషన్లు

Key technical specifications for the SASKATE 3.7V Lithium Battery Over Discharge Module:

పరామితివిలువ
అప్లికేషన్ ఫీల్డ్3.7V లిథియం బ్యాటరీ
ఓవర్‌ఛార్జ్ డిటెక్షన్ వాల్యూమ్tage4.28± 0.05V
ఓవర్‌ఛార్జ్ విడుదల వాల్యూమ్tage4.26± 0.05V
Over-Discharge Detection Voltage2.5± 0.1V
Overcurrent Detection Current1-3A
Overcurrent Release3.2±0.2A
మోడల్ సంఖ్యSASKATEg1md94kzr8
ప్యాకేజీ కొలతలు1.18 x 1.18 x 0.79 అంగుళాలు
బరువు0.11 ఔన్సులు
తయారీదారుSASKATE
మూలం దేశంచైనా

7. వారంటీ మరియు మద్దతు

For any questions, technical assistance, or warranty inquiries regarding your SASKATE 3.7V Lithium Battery Over Discharge Module, please contact your retailer or the manufacturer directly.

నిర్దిష్ట వారంటీ నిబంధనలు మరియు షరతుల కోసం దయచేసి మీ కొనుగోలు డాక్యుమెంటేషన్‌ను చూడండి.