Fuzion TGD-50

Fuzion Milligram Scale TGD-50 User Manual

Model: TGD-50 | Brand: Fuzion

1. పరిచయం

The Fuzion Milligram Scale TGD-50 is a high-precision digital scale designed for accurate weighing of small quantities. It offers a maximum capacity of 50 grams with a readability of 0.001g (1mg) and an accuracy within ±0.003g. This scale is suitable for measuring items such as powders, medicines, jewelry, gold, and gems. It features a large LCD display for clear readings and adjustable feet for stable operation.

2. ప్యాకేజీ విషయాలు

ప్యాకేజీలో అన్ని అంశాలు ఉన్నాయని నిర్ధారించుకోండి:

  • Fuzion Milligram Scale TGD-50
  • 50g కాలిబ్రేషన్ బరువు
  • 2 Silicone Storage Boxes
  • 1 సిలికాన్ బౌల్
  • 1 చెంచా
  • 1 ట్వీజర్
  • 1 క్లీనింగ్ బ్రష్
  • USB కేబుల్
  • 4 AAA Batteries (may be pre-installed)
  • వినియోగదారు మాన్యువల్

3. సెటప్

3.1 బ్యాటరీ ఇన్‌స్టాలేషన్

If batteries are not pre-installed, open the battery compartment cover on the underside of the scale. Insert 4 AAA batteries, ensuring correct polarity. Close the battery compartment. The scale can also be powered via the included USB cable.

3.2 ప్లేస్‌మెంట్ మరియు లెవలింగ్

Place the scale on a flat, stable surface free from vibrations and drafts. Use the adjustable feet at the bottom of the scale to level it. Observe the bubble level indicator, typically located near the weighing platform, to ensure the scale is perfectly horizontal for accurate readings.

Fuzion Milligram Scale with adjustable feet and bubble level for accurate weighing.

Image: Adjustable feet and bubble level for ensuring scale balance.

4. ఆపరేటింగ్ సూచనలు

4.1 పవర్ ఆన్/ఆఫ్

  • Press the "ON/OFF" button to turn the scale on.
  • Press and hold the "ON/OFF" button to turn the scale off.

4.2 యూనిట్ మార్పిడి

The scale supports 6 weighing units: grams (g), ounces (oz), troy ounces (ozt), pennyweights (dwt), carats (ct), and grains (gn).

  • Press the "MODE" button to cycle through the available weighing units. The selected unit will be displayed on the LCD screen.
Fuzion Milligram Scale displaying various weighing units: grams, ounces, troy ounces, pennyweights, carats, and grains.

Image: Display showing the six available weighing modes.

4.3 తారే ఫంక్షన్

The Tare function allows you to zero out the weight of a container or pan, so you only measure the contents.

  • బరువు వేసే వేదికపై ఖాళీ పాత్రను ఉంచండి.
  • Press the "TARE" button. The display will reset to zero.
  • తూకం వేయవలసిన వస్తువులను కంటైనర్‌లో జోడించండి. డిస్ప్లే వస్తువుల నికర బరువును చూపుతుంది.

4.4 కౌంటింగ్ ఫంక్షన్ (PCS)

The PCS function allows you to count the number of pieces of an item based on a sample బరువు.

  • ఇలా ఉంచండిample quantity (e.g., 25, 50, 75, or 100 pieces) of the item on the platform.
  • Press and hold the "PCS" button until the display shows a sample size (e.g., "25 PCS").
  • Press the "MODE" button to select the correct sample size corresponding to the number of items on the platform.
  • Press "PCS" again to confirm. The scale is now in counting mode.
  • Add more items to the platform, and the display will show the total count.

4.5 ఆటో-ఆఫ్ ఫంక్షన్

To conserve battery life, the scale will automatically shut off after 180 seconds of inactivity. This duration is fixed and cannot be adjusted.

Close-up of the Fuzion Milligram Scale's large backlit LCD display showing '0.000 g' and control buttons.

Image: Large, easy-to-read LCD display of the scale.

5. క్రమాంకనం

Regular calibration ensures the accuracy of your scale. A 50g calibration weight is included for this purpose.

  1. స్కేల్ ఆన్ చేయండి.
  2. Press and hold the "MODE" button until the display shows "CAL".
  3. The display will then flash "50.000g". Place the 50g calibration weight precisely in the center of the weighing platform.
  4. Wait for the display to show "PASS" and then return to normal weighing mode. The scale is now calibrated.
Four-step visual guide for calibrating the Fuzion Milligram Scale using a 50g weight.

Image: Step-by-step guide for easy calibration.

6. నిర్వహణ

6.1 శుభ్రపరచడం

Use the included small brush to gently clean any dust or residue from the weighing platform and surrounding areas. For stubborn dirt, wipe with a soft, damp వస్త్రం. రాపిడి క్లీనర్లను ఉపయోగించవద్దు లేదా స్కేల్‌ను నీటిలో ముంచవద్దు.

6.2 నిల్వ

When not in use, store the scale in a dry, stable environment. The scale features a windshield design to protect the weighing mechanism from environmental factors. Keep the protective cover closed during storage.

7. ట్రబుల్షూటింగ్

If you encounter any issues with your Fuzion Milligram Scale, please try the following:

  • సరికాని రీడింగ్‌లు: Ensure the scale is on a level, stable surface and recalibrate it using the 50g weight. Check for any obstructions under the weighing platform.
  • డిస్ప్లే ఆన్ కావడం లేదు: Verify that the batteries are correctly installed and have sufficient charge. If using USB power, ensure the cable is securely connected.
  • హెచ్చుతగ్గుల రీడింగ్‌లు: Ensure there are no air currents (e.g., from fans, open windows) affecting the scale.

For further assistance, please contact Fuzion Support.

8. స్పెసిఫికేషన్లు

బ్రాండ్ఫ్యూజన్
మోడల్TGD-50
గరిష్ట బరువు సామర్థ్యం50 గ్రాములు
Minimum Readability0.001గ్రా (1మి.గ్రా)
ఖచ్చితత్వం± 0.003గ్రా
బరువు యూనిట్లుg, oz, ozt, dwt, ct, gn
ప్రదర్శన రకంLCD
మెటీరియల్యాక్రిలోనిట్రైల్ బుటాడిన్ స్టైరిన్, స్టెయిన్‌లెస్ స్టీల్
వస్తువు బరువు0.47 కిలోలు
కొలతలు (సుమారుగా)5.90 in x 3.66 in x 1.38 in
శక్తి మూలం4 AAA Batteries or USB Cable
Fuzion Milligram Scale with dimensions labeled: 5.90 inches length, 3.66 inches width, 1.38 inches height.

Image: Approximate dimensions of the Fuzion Milligram Scale.

9. వారంటీ మరియు మద్దతు

Fuzion offers a 2-సంవత్సరాల వారంటీ మరియు జీవితకాల మద్దతు for this digital scale. Our dedicated Fuzion support team is available to assist with any questions or concerns you may have. Please refer to the warranty card included in your package for detailed terms and conditions, or contact Fuzion directly for support.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.