ZUKED-320-1.5KW

జెనరిక్ ZUKED-320-1.5KW VFD వేరియబుల్ ఫ్రీక్వెన్సీ డ్రైవ్ యూజర్ మాన్యువల్

Model: ZUKED-320-1.5KW

1. ఉత్పత్తి ముగిసిందిview

The Generic ZUKED-320-1.5KW Variable Frequency Drive (VFD) is designed to control the speed and torque of AC induction motors. This model specifically supports a single-phase 220V input and provides a three-phase 220V output, suitable for various industrial applications requiring precise motor control.

ముందు view of the ZUKED-320-1.5KW VFD

మూర్తి 1: ముందు view of the ZUKED-320-1.5KW VFD, showing the control panel with LED display and buttons.

ముఖ్య లక్షణాలు:

  • Input/Output Compatibility: Single-phase 220V input, three-phase 220V output, suitable for 1.5KW industrial motors.
  • మోటార్ నియంత్రణ: Advanced vector control technology for precise torque and speed regulation (±0.5% speed accuracy).
  • రక్షణ లక్షణాలు: ఓవర్‌కరెంట్, ఓవర్‌వోల్టును కలిగి ఉంటుందిtage, overload, phase loss, and short circuit protection for enhanced safety and longevity.
  • ఇంటిగ్రేటెడ్ విధులు: Built-in PID controller, simple PLC function, and output voltage regulation (AVR) function.
  • కనెక్టివిటీ: RS485 communication and multiple I/O ports for seamless integration into automation systems.
  • పర్యావరణ పరిరక్షణ: Compact design with an IP55-rated enclosure, offering dust and water resistance for demanding workshop conditions.
  • సమర్థత: Energy-saving mode automatically adjusts output to match load demands, potentially reducing power consumption.
  • EMC Filter: Built-in EMC filter to minimize electromagnetic interference.

2. భద్రతా సమాచారం

హెచ్చరిక: ఈ భద్రతా సూచనలను పాటించడంలో విఫలమైతే తీవ్రమైన గాయం లేదా మరణం సంభవించవచ్చు.

  • మాన్యువల్ చదవండి: Always read and understand this entire manual before installing, operating, or performing maintenance on the VFD.
  • విద్యుత్ ప్రమాదం: ఈ పరికరం అధిక వాల్యూమ్‌తో పనిచేస్తుందిtages. Ensure power is disconnected and wait at least 10 minutes after power-off before touching any internal components or removing the cover. Capacitors may retain a dangerous charge.
  • అర్హత కలిగిన సిబ్బంది: Installation, wiring, and maintenance must only be performed by qualified electrical personnel.
  • మౌంటు ఉపరితలం: Mount the inverter on a non-combustible surface to prevent fire hazards. Ensure adequate ventilation.
  • గ్రౌండింగ్: Ensure the VFD is properly grounded according to local electrical codes and regulations.
  • పర్యావరణ పరిస్థితులు: Do not expose the VFD to direct sunlight, excessive dust, corrosive gases, flammable materials, or extreme temperatures.
  • అత్యసవర నిలుపుదల: Always install an external emergency stop circuit.
ముందు view of VFD with voltage and power rating

మూర్తి 2: ముందు view highlighting the 220V input/output and 1.5KW power rating, along with safety labels.

3. సంస్థాపన మరియు సెటప్

3.1 మౌంటు

The VFD should be mounted vertically on a flat, non-combustible surface. Ensure sufficient clearance around the unit for proper ventilation and heat dissipation. Avoid mounting in areas subject to vibration or direct impact.

వైపు view of the VFD showing cooling fins and ventilation

మూర్తి 3: వైపు view of the VFD, illustrating the cooling fins and ventilation slots for heat dissipation.

3.2 వైరింగ్

All wiring must comply with local and national electrical codes. Use appropriate wire gauges for the VFD's power rating. Ensure all connections are secure and properly insulated.

  • Power Input (L, N, G): Connect the single-phase 220V AC power supply to the designated input terminals. Ensure proper grounding.
  • మోటార్ అవుట్‌పుట్ (U, V, W): Connect the three-phase 220V AC motor to the output terminals.
  • నియంత్రణ టెర్మినల్స్: Connect external control signals (e.g., start/stop, speed reference, fault reset) to the control terminals as required by your application. Refer to the detailed wiring diagram in the full product manual for specific terminal assignments.
టాప్ view of the VFD showing terminal blocks for wiring

మూర్తి 4: టాప్ view of the VFD, showing the accessible terminal blocks for power and control wiring.

3.3 ప్రారంభ పవర్-అప్

Before applying power, double-check all wiring connections. Ensure no loose wires or short circuits. Apply power and observe the VFD's display. If any error codes appear, refer to the troubleshooting section.

4. ఆపరేటింగ్ సూచనలు

The VFD features a user-friendly control panel for basic operation and parameter adjustments.

Close-up of the VFD control panel

Figure 5: Close-up of the VFD control panel, showing the LED display, rotary knob, and function buttons.

4.1 కంట్రోల్ ప్యానెల్ విధులు:

  • LED డిస్ప్లే: Shows operating status, frequency, current, voltage, మరియు ఎర్రర్ కోడ్‌లు.
  • రోటరీ నాబ్: Used for adjusting frequency/speed and navigating parameters.
  • PRG/SET Button: Enters/exits parameter setting mode and confirms selections.
  • JOG/ESC Button: Initiates jog operation (momentary run) and cancels current operation or exits a menu.
  • పైకి/క్రిందికి బాణాలు: Used to navigate through parameters or adjust values.
  • రన్ బటన్: మోటారును ప్రారంభిస్తుంది.
  • STOP/RES Button: Stops the motor and resets fault conditions.

4.2 ప్రాథమిక ఆపరేషన్:

  1. ప్రారంభం: నొక్కండి రన్ మోటారును ప్రారంభించడానికి బటన్.
  2. ఆపు: నొక్కండి STOP/RES మోటారును ఆపడానికి బటన్.
  3. వేగం సర్దుబాటు: Rotate the rotary knob to adjust the output frequency and motor speed.
  4. పారామీటర్ సెట్టింగ్: నొక్కండి PRG/SET to enter parameter mode. Use arrow keys to navigate and the rotary knob or arrow keys to change values. Press PRG/SET సేవ్ మరియు నిష్క్రమించడానికి మళ్లీ.

For detailed parameter settings and advanced functions, refer to the comprehensive programming guide provided with the full product documentation.

5. నిర్వహణ

Regular maintenance ensures optimal performance and extends the lifespan of your VFD.

  • పవర్ డిస్‌కనెక్ట్: Always disconnect power and wait at least 10 minutes before performing any maintenance.
  • శుభ్రపరచడం: Periodically clean the VFD's exterior and ventilation openings to prevent dust accumulation, which can hinder cooling. Use a soft, dry cloth. Do not use liquid cleaners.
  • తనిఖీ: Regularly inspect wiring connections for tightness and signs of damage or corrosion. Check for any unusual noises or odors during operation.
  • ఫ్యాన్ చెక్: కూలింగ్ ఫ్యాన్ స్వేచ్ఛగా పనిచేస్తుందని మరియు దానికి అడ్డంకులు లేకుండా చూసుకోండి.

6. ట్రబుల్షూటింగ్

If the VFD encounters an issue, the LED display may show an error code. Refer to the full product manual for a complete list of error codes and their solutions. Below are some common issues and general troubleshooting steps:

సమస్య సాధ్యమైన కారణం పరిష్కారం
VFD పవర్ ఆన్ చేయదు No input power; incorrect wiring; internal fuse blown. Check power supply; verify input wiring; consult qualified technician for fuse replacement.
మోటారు నడవదు Incorrect motor wiring; VFD in fault state; control signal issue. Verify motor wiring (U, V, W); check VFD display for error codes and reset; ensure RUN command is active.
ఓవర్ కరెంట్ లోపం Motor overload; short circuit in motor or wiring; acceleration time too short. Reduce motor load; check motor and wiring for shorts; increase acceleration time parameter.
ఓవర్‌వోల్tagఇ తప్పు ఇన్పుట్ వాల్యూమ్tage too high; deceleration time too short; regenerative load. ఇన్‌పుట్ వాల్యూమ్‌ని ధృవీకరించండిtage; increase deceleration time parameter; consider adding a braking resistor if applicable.

ఈ పరిష్కారాలను ప్రయత్నించిన తర్వాత కూడా సమస్య కొనసాగితే, సాంకేతిక మద్దతును సంప్రదించండి.

7. స్పెసిఫికేషన్లు

ఫీచర్ వివరాలు
మోడల్ ZUKED-320-1.5KW
ఇన్పుట్ వాల్యూమ్tage Single-phase 220V AC
అవుట్పుట్ వాల్యూమ్tage Three-phase 220V AC
రేట్ అవుట్పుట్ పవర్ 1.5KW
అవుట్పుట్ ఫ్రీక్వెన్సీ పరిధి 0-400Hz
నియంత్రణ పద్ధతి వెక్టర్ నియంత్రణ
రక్షణ ఓవర్ కరెంట్, ఓవర్వాల్tage, ఓవర్‌లోడ్, ఫేజ్ లాస్, షార్ట్ సర్క్యూట్
అంతర్నిర్మిత విధులు PID Controller, Simple PLC, AVR Function, EMC Filter
కమ్యూనికేషన్ RS485
సర్టిఫికేషన్ CE
వస్తువు బరువు సుమారు 3.53 ఔన్సులు (100 గ్రాములు) (Note: This weight may refer to a component or packaging; actual unit weight may vary.)
ప్యాకేజీ కొలతలు 0.39 x 0.39 x 0.39 అంగుళాలు (గమనిక: ఈ కొలతలు ప్లేస్‌హోల్డర్ విలువలుగా కనిపిస్తాయి మరియు వాస్తవ ఉత్పత్తి పరిమాణాన్ని ప్రతిబింబించకపోవచ్చు.)

8. వారంటీ మరియు మద్దతు

For warranty information, please refer to the documentation provided at the time of purchase or contact your seller directly. Technical support may be available through the manufacturer or authorized distributors.

Always ensure you have your product model number (ZUKED-320-1.5KW) and purchase details ready when seeking support.

సంబంధిత పత్రాలు - ZUKED-320-1.5KW

ముందుగాview VLT® HVAC Drive FC 102 Operating Guide - Danfoss
Explore the Danfoss VLT® HVAC Drive FC 102 Operating Guide. This comprehensive manual details safe installation, electrical setup, operation, troubleshooting, and maintenance for HVAC applications. Find specifications and resources.
ముందుగాview హారిస్టియన్ హెచ్‌ఆర్‌ఎస్‌టిఐ 320 సీరియస్: రొకోవోడ్స్‌వో పో ఎక్స్‌ప్ల్యూటాసి ప్రోబ్రాజోవాటెల్ చస్టోటీస్
పాడ్రోబ్నో రూకోవొడ్స్ట్వో పో ఎక్సప్ల్యూటస్ ద్వారా ప్రోబ్రాజోవాటేలీ చాస్తోటీ సెరిస్ హారిస్టియన్ హెచ్‌ఆర్‌ఎస్‌టి 320. యూజ్నకోమ్‌స్టొస్ నాస్ట్రోయ్కోయ్ మరియు బెజోపస్నిమ్ ఐస్పోల్జోవానియం.
ముందుగాview Small General Frequency Converter Operating Instruction - Model XM-H0126
Comprehensive operating instructions for the XM-H0126 small general frequency converter, covering installation, wiring, commissioning, parameters, applications, and troubleshooting. Supports 220V and 400V levels.
ముందుగాview Noark Ex9VF7 వేరియబుల్ ఫ్రీక్వెన్సీ డ్రైవ్‌లు: ఉత్పత్తి ముగిసిందిview మరియు స్పెసిఫికేషన్లు
సమర్థవంతమైన మోటార్ నియంత్రణ కోసం రూపొందించబడిన వేరియబుల్ ఫ్రీక్వెన్సీ డ్రైవ్‌ల (VFDలు) Noark Ex9VF7 శ్రేణిని కనుగొనండి. ఈ పత్రం సమగ్రమైన ఓవర్‌ను అందిస్తుందిview, technical specifications, product catalog, accessories, and dimensional data for the Ex9VF7 VFDs, suitable for various industrial applications.
ముందుగాview LSIS G100 జనరల్ AC డ్రైవ్: అధిక పనితీరు, విశ్వసనీయత మరియు బహుముఖ ప్రజ్ఞ
అధిక పనితీరు, సెన్సార్‌లెస్ ఆపరేషన్, ప్రీమియం నాణ్యత మరియు బలమైన విశ్వసనీయతను అందించే బహుముఖ పారిశ్రామిక పరిష్కారం అయిన LSIS G100 జనరల్ AC డ్రైవ్‌ను అన్వేషించండి. ఈ బ్రోచర్ దాని అధునాతన లక్షణాలు, స్పెసిఫికేషన్‌లు మరియు అప్లికేషన్‌లను వివరిస్తుంది.
ముందుగాview Small General Frequency Converter Operating Instruction XM-H0126
Operating instructions, safety precautions, parameter lists, installation, commissioning, and applications for the XM-H0126 Small General Frequency Converter. Covers 220V and 400V models.