1. పరిచయం
The WALFRONT REX C100 is a high-precision PID temperature controller designed for various industrial and commercial applications. It utilizes advanced self-tuning PID technology to ensure rapid temperature adjustments with minimal overshoot, providing accurate and stable temperature control. This manual provides essential information for the safe and efficient operation of your REX C100 controller.
Key applications include food processing, chemical industries, injection molding, and other environments requiring precise thermal monitoring and control.
2. భద్రతా సమాచారం
- విద్యుత్ ప్రమాదం: Always disconnect power before installation, wiring, or maintenance to prevent electric shock.
- సరైన వైరింగ్: Ensure all wiring connections are secure and comply with local electrical codes. Incorrect wiring can cause damage to the device or pose a fire hazard.
- పర్యావరణ పరిస్థితులు: Operate the controller within the specified temperature and humidity ranges. Avoid exposure to corrosive gases, excessive dust, or moisture.
- అర్హత కలిగిన సిబ్బంది: ఇన్స్టాలేషన్ మరియు వైరింగ్ను అర్హత కలిగిన సిబ్బంది మాత్రమే నిర్వహించాలి.
- ఉద్దేశించిన ఉపయోగం: Use the device only for its intended purpose as a temperature controller. Do not modify the device.
3. ప్యాకేజీ విషయాలు
ప్యాకేజీలో అన్ని అంశాలు ఉన్నాయని నిర్ధారించుకోండి:
- 1 x WALFRONT REX C100 PID Temperature Controller
4. ఉత్పత్తి ముగిసిందిview
The REX C100 features a clear digital display and intuitive controls for easy operation.

మూర్తి 4.1: ముందు కోణంలో View of REX C100 Controller. This image displays the front panel of the REX C100 PID Temperature Controller from an angled perspective. It clearly shows the dual digital displays for Process Value (PV) and Set Value (SV), along with indicator lights for ALM1, ALM2, OUT1, and AT. The 'SET' button and arrow keys are visible at the bottom left.
ముందు ప్యానెల్ వివరణ
- PV Display (Upper): Shows the current Process Value (measured temperature).
- SV Display (Lower): Shows the Set Value (target temperature).
- ALM1 Indicator: అలారం 1 యాక్టివ్గా ఉన్నప్పుడు వెలుగుతుంది.
- ALM2 Indicator: అలారం 2 యాక్టివ్గా ఉన్నప్పుడు వెలుగుతుంది.
- OUT1 Indicator: నియంత్రణ అవుట్పుట్ యాక్టివ్గా ఉన్నప్పుడు వెలుగుతుంది.
- AT సూచిక: Illuminates during auto-tuning (self-tuning PID).
- సెట్ బటన్: Used to enter parameter setting mode and confirm selections.
- Arrow Buttons (Up/Down/Left): మెనూలను నావిగేట్ చేయడానికి మరియు విలువలను సర్దుబాటు చేయడానికి ఉపయోగించబడుతుంది.
Rear Panel and Terminals

మూర్తి 4.2: వెనుక View with Wiring Terminals. This image shows the back of the REX C100 controller, highlighting the screw terminals for electrical connections and the product label with specifications and a basic wiring diagram.
The rear panel contains the screw terminals for power input, sensor input, and control outputs. Refer to the wiring diagram on the device label for precise connections.
5. సెటప్
5.1 మౌంటు
The REX C100 is designed for panel mounting. Cut an appropriate opening in your control panel according to the device dimensions. Insert the controller into the opening and secure it using the provided mounting brackets from the rear.

మూర్తి 5.1: REX C100 with Mounting Bracket. This image shows the REX C100 controller with its black plastic mounting bracket, illustrating how the device is secured into a panel cutout.
5.2 వైరింగ్
WARNING: Ensure power is disconnected before performing any wiring.
Refer to the wiring diagram printed on the side label of the controller for accurate connections. A typical wiring configuration is as follows:

మూర్తి 5.2: Wiring Diagram on Product Label. This image provides a close-up of the REX C100's side label, which includes a comprehensive wiring diagram for power, sensor input, and output connections.
- Power Supply (Terminals 1 & 2): Connect your 100-240VAC, 50/60Hz power source here.
- Output (OUT1) (Terminals 3, 4, 5): These are relay contacts. Connect your heating or cooling element through these terminals. The diagram shows Normally Open (NO) and Common (COM) connections.
- Alarm 1 (ALM1) (Terminals 6 & 7): Connect external alarm devices here.
- Alarm 2 (ALM2) (Terminals 8 & 9): Connect external alarm devices here.
- Sensor Input (Terminals 10 & 11): Connect your K-type thermocouple here. Ensure correct polarity for accurate readings.
After wiring, double-check all connections before applying power.
6. ఆపరేటింగ్ సూచనలు
6.1 పవర్ ఆన్
Once wired correctly, apply power to the controller. The PV display will show the current temperature measured by the thermocouple, and the SV display will show the set target temperature.
6.2 లక్ష్య ఉష్ణోగ్రత (SV) ను సెట్ చేయడం
- నొక్కండి సెట్ ఒకసారి బటన్ నొక్కితే SV డిస్ప్లే ఫ్లాష్ అవ్వడం ప్రారంభమవుతుంది.
- ఉపయోగించండి Up మరియు క్రిందికి arrow buttons to adjust the target temperature. The ఎడమ arrow button can be used to shift the cursor for faster adjustment of individual digits.
- నొక్కండి సెట్ button again to confirm the new SV. The display will stop flashing, and the controller will begin to regulate the temperature to the new set point.
6.3 PID Auto-Tuning
The REX C100 features an expert self-tuning PID function. Auto-tuning helps the controller learn the characteristics of your specific heating/cooling system to optimize control performance and minimize overshoot or undershoot.
To initiate auto-tuning:
- Ensure the system is at a stable temperature, preferably near your desired set point.
- నొక్కండి మరియు పట్టుకోండి సెట్ button for approximately 3-5 seconds until the controller enters the parameter setting menu.
- Navigate through the parameters (using arrow keys) until you find the auto-tuning parameter (often labeled 'AT' or similar).
- Set the auto-tuning parameter to '1' (or 'ON') and confirm with the సెట్ button. The 'AT' indicator light on the front panel will illuminate.
- The controller will cycle the output to determine the optimal PID parameters. This process may take some time (e.g., several heating/cooling cycles).
- Once auto-tuning is complete, the 'AT' indicator will turn off, and the controller will operate with the newly optimized PID parameters.
Note: Specific parameter codes and navigation may vary slightly. Refer to the detailed programming manual (if available) for advanced settings.
6.4 అలారం సెట్టింగ్లు
The REX C100 includes two alarm outputs (ALM1, ALM2). These can be configured for various alarm types (e.g., high limit, low limit, deviation) and hysteresis. Access these settings through the parameter menu by pressing and holding the సెట్ బటన్.
7. నిర్వహణ
- శుభ్రపరచడం: Clean the front panel with a soft, dry cloth. Do not use abrasive cleaners or solvents.
- పర్యావరణ తనిఖీ: Periodically inspect the operating environment to ensure it remains free of corrosive gases, excessive dust, and moisture.
- కనెక్షన్ తనిఖీ: Occasionally check wiring connections for tightness, especially in environments with vibration.
- సెన్సార్ తనిఖీ: Inspect the thermocouple for any signs of damage or corrosion that could affect accuracy.
8. ట్రబుల్షూటింగ్
| సమస్య | సాధ్యమైన కారణం | పరిష్కారం |
|---|---|---|
| కంట్రోలర్ పవర్ ఆన్ చేయదు. | విద్యుత్ సరఫరా లేదు; వైరింగ్ తప్పు. | Check power connections (Terminals 1 & 2). Ensure voltage 100-240VAC లోపల ఉంది. |
| PV display shows 'HHHH' or 'LLLL'. | Thermocouple open circuit or reverse connection. | Check thermocouple wiring (Terminals 10 & 11) for breaks or incorrect polarity. Ensure it is a K-type thermocouple. |
| ఉష్ణోగ్రత రీడింగ్ తప్పుగా ఉంది. | Incorrect sensor type selected (if configurable); sensor fault; environmental interference. | Verify sensor type. Check sensor for damage. Ensure proper shielding if in an electrically noisy environment. |
| Output (OUT1) not activating. | SV not reached; output parameter incorrect; wiring issue. | Check SV. Verify output control mode. Inspect output wiring (Terminals 3, 4, 5). |
| Temperature overshoots/undershoots target. | PID parameters not optimized. | Perform PID auto-tuning (refer to Section 6.3). |
9. స్పెసిఫికేషన్లు
| ఫీచర్ | స్పెసిఫికేషన్ |
|---|---|
| మోడల్ | REX-C100 |
| నియంత్రణ రకం | ఉష్ణోగ్రత |
| నియంత్రణ మోడ్ | RELAY (Output) |
| Measurement Objects | All objects (with compatible K-type thermocouple) |
| ఉష్ణోగ్రత కొలత లోపం | ±1% (℃) |
| వర్కింగ్ వాల్యూమ్tage | 100-240VAC |
| కొలత ఖచ్చితత్వం | ± 0.5%FS |
| రిజల్యూషన్ | 14 బిట్ |
| ఇన్సులేషన్ బలం | 1500VAC/1 నిమిషం |
| బరువు | 164గ్రా (సుమారు 6 ఔన్సులు) |
| Temperature Range (K-Type) | 0-400°C (32-752°F) |
| ఆపరేటింగ్ ఎన్విరాన్మెంట్ | 0-50℃ (32-122°F), 30-85% RH, free of corrosive gas |
| ప్యాకేజీ కొలతలు | 5.51 x 2.76 x 2.36 అంగుళాలు |
10. వారంటీ మరియు మద్దతు
ఈ ఉత్పత్తి సామాగ్రి మరియు పనితనంలోని లోపాలపై ప్రామాణిక తయారీదారు వారంటీ ద్వారా కవర్ చేయబడింది. నిర్దిష్ట వారంటీ నిబంధనలు మరియు వ్యవధి కోసం దయచేసి మీ కొనుగోలు డాక్యుమెంటేషన్ను చూడండి.
సాంకేతిక మద్దతు, ట్రబుల్షూటింగ్ సహాయం లేదా వారంటీ క్లెయిమ్ల కోసం, దయచేసి మీ రిటైలర్ లేదా తయారీదారుని నేరుగా సంప్రదించండి. కొనుగోలు రుజువుగా మీ కొనుగోలు రసీదును ఉంచండి.