1. పరిచయం
The Riello RG3 Light Oil Burner is engineered for efficient operation in low or medium temperature hot water boilers, hot air generators, and steam boilers. This burner features a balanced flue system, ensuring combustion products are isolated from the installation environment and drawing fresh air from outside. This design minimizes unpleasant odors and reduces operational noise through fully sealed components like the motor and oil pump. Manufactured to European and OFTEC standards, the RG3 burner offers reliable performance for various industrial applications.
2. స్పెసిఫికేషన్లు
| గుణం | వివరాలు |
|---|---|
| టైప్ చేయండి | లైట్ ఆయిల్ బర్నర్ |
| బ్రాండ్ పేరు | Riello (VYOPBC) |
| మోడల్ | RG3 |
| శక్తి మూలం | లైట్ ఆయిల్ |
| DIY సామాగ్రి | ఎలక్ట్రికల్ |
| మూలం | Italy (Manufacturing in Mainland China) |
| సర్టిఫికేషన్ | CE |
| వర్తించే పరిశ్రమలు | Manufacturing Plant, Food & Beverage Factory, Construction works, Energy Sector |
| పరిస్థితి | కొత్తది |
| పరిమాణం (L*W*H) | అనుకూలీకరించబడింది |
| బరువు | 76 KG |
| వారంటీ | 1 Year (15 months from seller) |
| పని ఉష్ణోగ్రత పరిధి | 0 - 40 ℃ |
| మెటీరియల్ | స్టెయిన్లెస్ స్టీల్ |
| కీ సెల్లింగ్ పాయింట్లు | Famous brand low voltagఇ భాగాలు |
| కోర్ కాంపోనెంట్స్ వారంటీ | 1 సంవత్సరం |
| కోర్ భాగాలు | Motor, Engine |
| యంత్రాల పరీక్ష నివేదిక | అందించబడింది |
| వీడియో అవుట్గోయింగ్-తనిఖీ | అందించబడింది |
| పర్యావరణ ఉష్ణోగ్రత | 40℃ |
3. ప్యాకేజీ విషయాలు
Upon receiving your Riello RG3 Light Oil Burner, please verify that the following components are included:
- బర్నర్ బాడీ
- ఫ్యాన్ భాగం
- Electric control part
- Valve combination
Generally, additional accessories are not required for basic operation. You will need to provide the light oil fuel and the necessary power supply.
4. సెటప్
Installation and setup of the Riello RG3 Light Oil Burner should be performed by qualified personnel in accordance with local regulations and safety standards. Refer to the detailed component diagram below for identification of parts during installation.

కాంపోనెంట్ ఐడెంటిఫికేషన్:
- బర్నర్
- జ్వలన ఎలక్ట్రోడ్లు
- Combustion head adjusting bolt
- Minimum air pressure switch (for different operating modes)
- Flame probe
- Wind pressure measuring points
- Fuel pressure measuring points and fixing bolts
- Bolts to secure the fan to the casing
- Slide bar for opening the burner and servicing the combustion head
- Servo motor (controls fuel butterfly valve and damper opening)
- Areas where cables are routed
- The air inlet of the fan
- ఇంధన ఇన్లెట్ పైపు
- Fuel Butterfly Valve
- Flange for fixing the burner to the boiler
- Flame stabilization plate
- అగ్ని viewరంధ్రం
- Switches for different operating modes: Auto - Manual - Off button: Increase output - decrease output
- Motor contactor and thermal protector with reset button (RS 44/M MZ three-phase power supply)
- Motor capacitor (RS 34-44/M MZ single-phase power supply)
- Control Box with Lockout Reset Button and Lockout Indicator
- కేబుల్ సాకెట్
- Damper డిamper
- Cable socket for ignition electrode
- Slide bar extension (for lengthening the front burner)
- 4-Pole Socket Cover (see Appliance Panel Appendix)
ఇన్స్టాలేషన్ దశలు (సాధారణం):
- Mount the burner securely to the boiler using the provided flange (15).
- Connect the fuel inlet pipe (13) to your light oil supply.
- Route all necessary electrical cables through the designated areas (11) and connect them to the control box (21) and other electrical components.
- Ensure proper ventilation and access to the fan air inlet (12).
- Verify all connections are secure and leak-free before proceeding.


5. ఆపరేటింగ్ సూచనలు
The Riello RG3 burner offers flexible operating modes to suit your system's needs.
ఆపరేటింగ్ మోడ్లు:
- ఆటో: The burner operates automatically based on system demand and temperature settings.
- మాన్యువల్: Allows for manual control of the burner's functions.
- ఆఫ్: Shuts down the burner.
Use the 'Increase output' and 'Decrease output' buttons (18) to adjust the burner's firing rate as required. The servo motor (10) automatically controls the fuel butterfly valve (14) and the damper (23) to optimize combustion. The damper is fully closed when the burner is stopped to reduce heat loss.
Monitor the flame through the fire viewing hole (17) to ensure stable combustion. The flame probe (5) continuously monitors the flame presence for safety.
6. నిర్వహణ
Regular maintenance is crucial for ensuring the longevity and efficient operation of your Riello RG3 Light Oil Burner. Always disconnect power before performing any maintenance.
Recommended Maintenance Tasks:
- వార్షిక తనిఖీ: Have a qualified technician inspect the burner annually.
- Combustion Head Cleaning: Periodically clean the combustion head to remove any soot or deposits that may affect performance. The slide bar (9) facilitates access for servicing.
- Electrode Check: Inspect the ignition electrodes (2) for wear and proper gap.
- Flame Probe Cleaning: Ensure the flame probe (5) is clean and free from obstructions.
- Air Inlet Cleaning: Keep the fan air inlet (12) clear of dust and debris to ensure adequate airflow.
- Pressure Checks: Verify readings at the wind pressure measuring points (6) and fuel pressure measuring points (7) are within specified ranges.
- విద్యుత్ భాగాలు: Check the motor contactor (19), motor capacitor (20), and all cable connections (11, 22, 24) for signs of wear or damage.
7. ట్రబుల్షూటింగ్
If your Riello RG3 burner encounters an issue, the control box (21) provides a lockout indicator to signal a fault. Always consult a qualified technician for complex issues.
సాధారణ సమస్యలు మరియు పరిష్కారాలు:
- Burner Lockout: If the lockout indicator on the control box (21) is active, press the Lockout Reset Button. If the issue persists, check fuel supply, ignition, and flame presence.
- ఇగ్నిషన్ లేదు: Verify the ignition electrodes (2) are clean and correctly positioned. Check for adequate fuel supply and proper electrical connections.
- Unstable Flame: Inspect the combustion head, flame stabilization plate (16), and ensure proper air/fuel mixture. Check the flame probe (5) for cleanliness.
- Air Pressure Fault: The minimum air pressure switch (4) will detect insufficient airflow. Check the fan air inlet (12) for obstructions and ensure the fan is operating correctly.
- మోటార్ సమస్యలు: If the motor is not running, check the motor contactor (19) and thermal protector. For three-phase models, check the reset button on the thermal protector. For single-phase models, check the motor capacitor (20).
8 వినియోగదారు చిట్కాలు
- Ensure you have a consistent supply of light oil fuel and the correct power supply for your burner model.
- Consider installing a temperature controller if your application requires precise temperature management, as this is an optional accessory.
- For optimal performance and safety, always adhere to the manufacturer's guidelines and local regulations during installation and operation.
9. వారంటీ మరియు మద్దతు
The Riello RG3 Light Oil Burner comes with a standard 1-year warranty. The seller provides an extended warranty of 15 months from the date of purchase. This warranty covers defects in materials and workmanship under normal use.
For after-warranty service, video technical support is available to assist with diagnostics and guidance.
సంప్రదింపు సమాచారం:
For technical support or warranty claims, please contact your seller or a certified Riello service provider.
విక్రేత సంప్రదింపు వివరాలు:
WhatsApp/WeChat: +86 18934733873
Email: wsc1183562764@outlook.com (Cassie)
10. ముఖ్యమైన భద్రతా సమాచారం
Please read and understand all safety warnings and instructions before installing, operating, or maintaining the Riello RG3 Light Oil Burner. Failure to follow these instructions could result in property damage, serious injury, or death.
- Installation and service must be performed by a qualified, licensed technician.
- సంస్థాపనా ప్రదేశంలో సరైన వెంటిలేషన్ ఉండేలా చూసుకోండి.
- Always disconnect electrical power before performing any maintenance or service.
- Do not store flammable materials near the burner.
- Regularly inspect the fuel lines for leaks.
- Never operate the burner if any components are damaged or missing.
- Keep children and unauthorized personnel away from the burner during operation.