1. పరిచయం
This manual provides comprehensive instructions for the safe and effective installation, operation, and maintenance of the Ranco O16-108 Pressure Control Switch. Please read this manual thoroughly before attempting to install or operate the device. Retain this manual for future reference.
2. భద్రతా సమాచారం
హెచ్చరిక: Electrical shock hazard. Disconnect power before installation or servicing. Installation and servicing must be performed by qualified personnel only. Failure to follow these instructions could result in serious injury or death.
- ఎల్లప్పుడూ తగిన వ్యక్తిగత రక్షణ పరికరాలు (PPE) ధరించండి.
- అన్ని వైరింగ్లు స్థానిక మరియు జాతీయ విద్యుత్ కోడ్లకు అనుగుణంగా ఉన్నాయని నిర్ధారించుకోండి.
- Do not exceed the specified electrical ratings of the device.
- Verify proper grounding to prevent electrical hazards.
3. ఉత్పత్తి ముగిసిందిview
The Ranco O16-108 is a robust pressure control switch designed for industrial applications. It features a durable housing, a clear pressure scale for precise adjustments, and a capillary tube for remote pressure sensing. This device is engineered to provide reliable switching based on detected pressure changes.

మూర్తి 1: Ranco O16-108 Pressure Control Switch. The image displays the main control unit with a visible pressure scale (showing values like 10, 15, 20, 30, 40, 50 in PSI and bar), the Ranco logo, and a capillary tube extending from the bottom, coiled, and terminating in a brass fitting. The scale indicates "CLOSES ON PRESSURE RISE" and "SWITCH LOW EVENT".
4. సెటప్ మరియు ఇన్స్టాలేషన్
Proper installation is crucial for the optimal performance and longevity of the Ranco O16-108. Consult a qualified technician for installation if you are not experienced with electrical and pressure systems.
4.1 మౌంటు
- Mount the control unit in a location free from excessive vibration, moisture, and extreme temperatures.
- Ensure adequate clearance for wiring and adjustments.
- Use appropriate fasteners to secure the unit firmly to a stable surface.
4.2 Pressure Connection
- Connect the capillary tube's brass fitting to the pressure source.
- Ensure a leak-free connection. Do not bend the capillary tube sharply, as this can damage the sensing element.
- The capillary tube transmits pressure changes to the control unit.
4.3 ఎలక్ట్రికల్ వైరింగ్
- Refer to the wiring diagram provided with the product (not included in this manual) for specific connections.
- Connect power supply and load wires to the appropriate terminals. The contact type is Normally Open (NO) and the terminal is SPDT (Single Pole Double Throw).
- అన్ని కనెక్షన్లు సురక్షితంగా మరియు ఇన్సులేట్గా ఉన్నాయని నిర్ధారించుకోండి.
5. ఆపరేటింగ్ సూచనలు
The Ranco O16-108 operates automatically based on the set pressure points. Adjustments are made via the visible scale on the front of the unit.
5.1 Setting Pressure Points
- Identify the desired cut-in and cut-out pressure values for your application.
- Use a small screwdriver or adjustment tool (if required) to move the indicators on the pressure scale to the desired settings. The scale shows values in both bar and PSI.
- The device is designed to close on pressure rise, meaning the switch will activate when the pressure reaches the set point.
- The "SWITCH LOW EVENT" and "MINUS DIFF" markings on the scale relate to setting the differential pressure.
5.2 Manual Operation / Reset (if applicable)
While the primary operation is automatic, some Ranco pressure controls may feature a manual reset or test button. If present, this button allows for manual activation or resetting of the switch. Consult the specific product labeling for details on any manual functions.
6. నిర్వహణ
The Ranco O16-108 is designed for minimal maintenance. Regular inspections are recommended to ensure continued reliable operation.
- దృశ్య తనిఖీ: Periodically check the unit for any signs of physical damage, corrosion, or loose connections.
- శుభ్రపరచడం: Keep the exterior of the control unit clean and free of dust and debris. Use a soft, dry cloth. Do not use abrasive cleaners or solvents.
- కేశనాళిక గొట్టం: Inspect the capillary tube for kinks, damage, or leaks. Ensure it is securely connected at both ends.
7. ట్రబుల్షూటింగ్
If the Ranco O16-108 is not functioning as expected, review the following common issues before contacting support.
- Device not switching:
- Check power supply to the unit.
- వైరింగ్ కనెక్షన్లు సరిగ్గా మరియు సురక్షితంగా ఉన్నాయని ధృవీకరించండి.
- Ensure the pressure is within the set operating range.
- Inspect the capillary tube for damage or blockages.
- సరికాని ఒత్తిడి రీడింగ్లు:
- Confirm the capillary tube is properly installed and free of leaks.
- Check for external factors affecting pressure sensing (e.g., temperature fluctuations at the sensing point).
- Unit appears damaged:
- Do not attempt to repair internal components. Contact a qualified service technician.
8. స్పెసిఫికేషన్లు
| ఫీచర్ | వివరాలు |
|---|---|
| బ్రాండ్ | రాంకో |
| మోడల్ సంఖ్య | O16-108 |
| ఉత్పత్తి కొలతలు (L x W x H) | 4.25 x 6.5 x 2.5 అంగుళాలు |
| వస్తువు బరువు | 1.3 పౌండ్లు |
| జాతీయ స్టాక్ సంఖ్య | 5930-00-708-1968 |
| ఆపరేషన్ మోడ్ | ఆటో |
| సంప్రదింపు రకం | సాధారణంగా తెరవండి |
| కనెక్టర్ రకం | స్క్రూ టెర్మినల్ |
| టెర్మినల్ | SPDT (సింగిల్ పోల్ డబుల్ త్రో) |
| సర్క్యూట్ రకం | 1-మార్గం |
| యాక్యుయేటర్ రకం | Push Button (likely for reset/test or internal mechanism) |
| సంప్రదింపు మెటీరియల్ | రాగి |
| అంతర్జాతీయ రక్షణ రేటింగ్ | IP00 |
9. వారంటీ మరియు మద్దతు
For warranty information, technical support, or service inquiries regarding your Ranco O16-108 Pressure Control Switch, please contact Ranco customer service or your authorized Ranco distributor. Keep your purchase receipt and model number handy when contacting support.
తయారీదారు: RANCO