1. పరిచయం
This manual provides comprehensive instructions for the installation, operation, and maintenance of the On-Q 42-inch Enclosure Hinged Cover-Lock (Model EN4250). This enclosure is designed to house and organize structured wiring components for residential and light commercial applications, providing a centralized and secure location for your network, voice, and video distribution systems.
The On-Q enclosure features a durable 20 Gauge CRS (Cold Rolled Steel) construction with a protective powder coat finish, ensuring longevity and reliability. Its versatile design allows for both flush and surface mounting, adapting to various installation requirements. The hinged, locking door provides secure access to internal components while maintaining a clean aesthetic.
2. ఉత్పత్తి ముగిసిందిview
The On-Q 42-inch Enclosure is engineered for efficient cable management and component organization. Key features include:
- Hinged, Locking Door: Provides secure access and conceals wiring.
- Universal Mounting Holes: Compatible with all On-Q bay-style modules.
- Large Top Openings: Facilitate easier wire pulling.
- Additional Knockouts: For flexible cable entry and electrical outlets.
- Side Lances and Tabs: Offer versatile mounting options for internal components.
- Drywall Depth Indicators: Aid in correct flush-mount positioning.
- Self-Adhesive Cable Identification Table: For organized wiring.
Figure 2.1: The On-Q 42-inch Enclosure with its hinged door open, showcasing the internal mounting points and cable management features.
Figure 2.2: Detailed dimensions of the EN4250 enclosure, including depth, width, and height measurements for both the enclosure body and the hinged door.
Figure 2.3: The keyed lock mechanism on the enclosure door, providing security for the housed components.
3. సంస్థాపన
The On-Q EN4250 enclosure can be installed using either recessed (in-wall) or surface mounting methods. Ensure all local electrical and building codes are followed during installation.
3.1 టూల్స్ మరియు మెటీరియల్స్ అవసరం
- డ్రిల్/డ్రైవర్
- స్థాయి
- Utility Knife or Hammer (for knockouts)
- స్క్రూడ్రైవర్ (ఫిలిప్స్ హెడ్ సిఫార్సు చేయబడింది)
- కొలిచే టేప్
- పెన్సిల్
- భద్రతా అద్దాలు
3.2 ఎన్క్లోజర్ను మౌంట్ చేయడం
- స్థానాన్ని ఎంచుకోండి: Choose a suitable location, typically between wall studs, that allows for easy access and cable routing. Ensure there is sufficient space for the enclosure's dimensions (approximately 14.3" W x 42.1" H x 3.7" D).
- Mark Keyhole Location: Hold the enclosure against the wall studs in the desired position. Mark the location of the top keyhole slot on the wall.
- Install Top Screw: Drive a screw into the marked keyhole location, leaving it slightly proud to allow the enclosure to hang.
- Hang and Level: Hang the enclosure on the top screw. Use a level to ensure the enclosure is plumb.
- Secure Remaining Tabs: Once level, drive screws into the remaining mounting tabs to secure the enclosure firmly to the wall studs.
Figure 3.1: Securing the enclosure to wall studs during installation. The enclosure can be recessed or surface mounted.
Figure 3.2: Details of the enclosure's rear access knockouts, keyhole opening for initial hanging, and standoffs for surface mounting.
3.3 Cable Entry and Power Installation
- Remove Knockouts: Use a utility knife or hammer to remove the desired cable entry knockouts at the top or bottom of the enclosure. The top openings are larger (2.5 inches) for easier wire pulling.
- Install Grommets (Optional): For protected cable entry, install On-Q rubber grommets (AC1034, sold separately) into the removed knockouts.
- రూట్ కేబుల్స్: Pull all necessary low-voltage cables (network, voice, video) through the chosen entry points into the enclosure.
- Install Electrical Outlets: If power is required inside the enclosure, remove the appropriate electrical knockouts at the bottom. Install On-Q Tamper Resistant Outlet Power Kit (F7526) or Surge Protected Power Outlet Kit (364569-02-V1) (sold separately) using the provided screws to affix the box to the enclosure. Terminate AC cabling to the receptacle and secure with a cover plate.
Figure 3.3: The large 2.5-inch top openings facilitate easy routing of multiple cables into the enclosure.
Figure 3.4: The two bottom knockouts are designed for installing standard electrical outlets, such as the On-Q F7526 or 364569-02-V1 (sold separately).
3.4 Drywall and Trim Installation
- Protect with Cable Guard: During drywall installation, use the provided cardboard cable guard to protect internal cables and keep them tidy.
- ట్రిమ్ రింగ్ని ఇన్స్టాల్ చేయండి: Once drywall is complete, mount the top trim piece first, then snap in additional perimeter pieces around the enclosure. Use a level and screw into additional mounting holes as needed.
- Attach Hinged Door: Snap the hinged door into the trim ring. The door can be reversed to open from either the left or right side.
3.5 ఇన్స్టాలేషన్ వీడియో గైడ్
ఇన్స్టాలేషన్ ప్రక్రియపై దృశ్య మార్గదర్శిని కోసం, దయచేసి దిగువన ఉన్న అధికారిక ఇన్స్టాలేషన్ వీడియోను చూడండి:
Video 3.1: Official installation guide for the On-Q Enclosure. This video demonstrates the steps for mounting the enclosure, managing cables, installing power outlets, and attaching the trim and hinged door.
4. ఆపరేషన్
The On-Q 42-inch Enclosure is primarily a passive housing unit designed to organize and protect your structured wiring components. Its operation involves managing the installed modules and cables.
- యాక్సెస్ భాగాలు: Use the provided key to unlock and open the hinged door. This allows full access to all installed modules, patch panels, and cables.
- కేబుల్ నిర్వహణ: Utilize the built-in lance points and cable management clips (AC1035-20, sold separately) to neatly route and secure cables within the enclosure, preventing tangles and improving airflow.
- మాడ్యూల్ ఇన్స్టాలేషన్: On-Q bay-style modules (e.g., video, voice, network distribution, Gigabit switches like DA1008) can be easily snapped into the universal mounting holes. Ensure modules are securely fastened.
- పవర్ అవుట్లెట్లు: If installed, the internal power outlets provide electricity to active components such as routers, switches, or media converters.
చిత్రం 4.1: ఒక మాజీample of a fully populated On-Q enclosure, demonstrating organized cabling and various installed modules for a structured wiring system.
Figure 4.2: Components such as Ethernet switches and network interface modules neatly organized within the enclosure, with cables managed for optimal performance.
Figure 4.3: Internal features like lance points for cable ties, drywall depth indicators, and flexible mounting tabs that enhance the enclosure's versatility and ease of use.
5. నిర్వహణ
The On-Q 42-inch Enclosure requires minimal maintenance to ensure its continued performance and the protection of your structured wiring system.
- సాధారణ తనిఖీ: Periodically open the enclosure and inspect all connections and components for any signs of wear, damage, or loose connections.
- దుమ్ము తొలగింపు: Use a soft, dry cloth or compressed air to remove any accumulated dust from inside the enclosure and from the components. Excessive dust can lead to overheating of active devices.
- కేబుల్ సంస్థ: Ensure cables remain neatly organized and secured to the lance points. Re-tie or adjust cable ties as needed to maintain proper airflow and prevent strain on connections.
- Door and Lock: Check the hinged door and lock mechanism for smooth operation. Lubricate the lock if it becomes stiff.
- పర్యావరణ పరిస్థితులు: Ensure the environment around the enclosure remains within specified humidity and temperature ranges to prevent damage to electronic components.
6. ట్రబుల్షూటింగ్
This section addresses common issues you might encounter with your On-Q 42-inch Enclosure.
| సమస్య | సాధ్యమైన కారణం | పరిష్కారం |
|---|---|---|
| తలుపు సరిగ్గా మూయదు లేదా తాళం వేయదు. | Misalignment of door or trim ring; obstruction; damaged hinge/latch. | Check for obstructions. Ensure trim ring is properly seated. Inspect hinges and latch for damage and adjust if possible. |
| Difficulty pulling cables through knockouts. | Knockout not fully removed; sharp edges; too many cables. | Ensure knockouts are completely removed. Use rubber grommets (AC1034) for smoother entry. Reduce cable bundle size or use additional knockouts. |
| Internal components overheating. | Poor airflow; excessive dust; too many active devices. | Ensure cables are neatly managed to allow airflow. Clean dust regularly. Consider adding a small ventilation fan if multiple heat-generating devices are installed. |
| Enclosure feels loose on the wall. | Mounting screws are loose or not fully engaged. | Tighten all mounting screws. If necessary, remove the enclosure, re-drill pilot holes, and re-mount securely. |
7. స్పెసిఫికేషన్లు
| గుణం | వివరాలు |
|---|---|
| మోడల్ సంఖ్య | EN4250 |
| కొలతలు (H x W x D) | 42.1" x 14.3" x 3.7" (Enclosure Body) 43.2" x 15.5" (Hinged Door) |
| మెటీరియల్ | 20 Gauge CRS (Cold Rolled Steel) |
| ముగించు | Protective Powder Coat (Glossy White) |
| సంస్థాపన రకం | Flush-Mount, Surface-Mount |
| బరువు | 19.76 పౌండ్లు |
| తేమ | గరిష్టంగా 93% నాన్-కండెన్సింగ్ |
| వర్తింపు | RoHS కంప్లైంట్ |
| చేర్చబడిన భాగాలు | (1) 42" Metal Enclosure with Hinged Door |
| UPC | 804428023180 |
8. వారంటీ మరియు మద్దతు
The On-Q 42-inch Enclosure Hinged Cover-Lock (Model EN4250) comes with a 1 సంవత్సరాల వారంటీ కొనుగోలు చేసిన తేదీ నుండి.
For technical support, warranty claims, or additional information, please contact On-Q customer service or visit their official website. Refer to the product packaging or the On-Q brand store on Amazon for the most current contact details.
Additional resources, including the full installation manual in PDF format, may be available online: