Red Lion 97101001

Red Lion RL-SPRK100 Sprinkler Pump User Manual

మోడల్: 97101001

1. ఉత్పత్తి ముగిసిందిview

The Red Lion RL-SPRK100 is a 1 HP sprinkler pump designed for residential and light commercial lawn and turf sprinkling systems. It features a rugged cast iron casing and a high-efficiency thermoplastic impeller and diffuser. This pump is engineered for reliable performance and ease of use.

Red Lion RL-SPRK100 Sprinkler Pump

Image 1.1: The Red Lion RL-SPRK100 Sprinkler Pump, showcasing its red cast iron housing.

ముఖ్య లక్షణాలు:

  • మన్నికైన నిర్మాణం: Features a rugged cast iron pump housing and a glass-filled thermoplastic impeller, suitable for various water sources including well water and lake water.
  • ద్వంద్వ వాల్యూమ్tage Motor: Operates on either 115 Volts or 230 Volts. The pump is factory-set to 230 Volts but can be easily reconfigured to 115 Volts. It is crucial to match the pump's voltage setting to the power source voltagఇ సరైన ఆపరేషన్ కోసం.
  • స్వీయ-ప్రైమింగ్ సామర్థ్యం: Requires only a one-time initial prime. No additional priming is necessary after the initial fill, simplifying setup.
  • అధిక పనితీరు: Delivers up to 63 Gallons Per Minute (GPM) at 10 PSI and 38 GPM at 30 PSI. Capable of supporting up to 12 sprinkler heads with 1/2-inch fittings or 6 sprinkler heads with 3/4-inch fittings per zone.
  • Standard Connections: Equipped with a 2-inch Female NPT threaded intake and a 1.5-inch Female NPT threaded discharge.
Red Lion RL-SPRK100 Sprinkler Pump Features

Image 1.2: Diagram highlighting key features of the pump, including the 2-inch FNPT intake, 1-1/2-inch FNPT discharge, cast iron casing, capacitor start, and thermally protected motor.

2. సెటప్ మరియు ఇన్‌స్టాలేషన్

Proper installation is essential for the safe and efficient operation of your Red Lion RL-SPRK100 Sprinkler Pump. Refer to the complete installation manual included with your pump for detailed instructions and safety warnings.

2.1 సంtagఇ కాన్ఫిగరేషన్

The pump motor is factory-set to 230 Volts. If your power supply is 115 Volts, you must adjust the motor's voltage setting before operation. Failure to match the pump's voltage to the source voltage will prevent the pump from performing to specifications and may cause damage.

Red Lion RL-SPRK100 Dual Voltage Motor Setting

Image 2.1: Instructions for setting the dual voltage motor. The pump is factory preset to 230V. To switch to 115V, insert a flat screwdriver into the black voltage change indicator and twist counter-clockwise.

2.2 పంపును ప్రైమింగ్ చేయడం

The RL-SPRK100 is a self-priming pump, meaning it only requires an initial prime. After the initial fill, no additional priming is typically required. Follow these general steps for initial priming:

  1. అన్ని ప్లంబింగ్ కనెక్షన్లు సురక్షితంగా మరియు లీక్-రహితంగా ఉన్నాయని నిర్ధారించుకోండి.
  2. Remove the priming plug (usually located on top of the pump casing).
  3. Fill the pump casing completely with water until it overflows.
  4. Replace and tighten the priming plug.
  5. Open any discharge valves to allow air to escape the system.
  6. Start the pump. It should begin pumping water within a few minutes. If not, turn off the pump, re-prime, and check for air leaks in the suction line.
Red Lion RL-SPRK100 Self-Priming Feature

Image 2.2: The Red Lion Sprinkler Pump positioned in a lawn setting, illustrating its self-priming capability up to 25 feet after the initial prime.

3. ఆపరేటింగ్ సూచనలు

Once properly installed and primed, the Red Lion RL-SPRK100 Sprinkler Pump is ready for operation. Ensure all connections are tight and there are no obstructions in the intake or discharge lines.

3.1 పంపును ప్రారంభించడం

Activate the power supply to the pump. The pump will begin to draw water and build pressure. Monitor the system for any unusual noises or leaks during initial startup.

Red Lion RL-SPRK100 Sprinkler Pump in operation

Image 3.1: The Red Lion Sprinkler Pump operating in a residential setting, drawing water from a well, lake, pond, or ditch for irrigation.

3.2 Performance Guidelines

The pump is designed to deliver consistent water flow and pressure for various sprinkler system configurations. Refer to the performance chart below for expected output based on dynamic head and flow rate.

Red Lion Sprinkler Pump Performance Chart

Image 3.2: Performance curve chart for Red Lion Centrifugal Sprinkler Pumps, including the RL-SPRK100, showing Total Dynamic Head (ft) versus Capacity (US gpm).

3.3 పంప్‌ను మూసివేయడం

To turn off the pump, deactivate the power supply. If the pump will be inactive for an extended period or during freezing temperatures, follow the maintenance guidelines for winterization.

4. నిర్వహణ

Regular maintenance ensures the longevity and optimal performance of your Red Lion RL-SPRK100 Sprinkler Pump.

4.1 దినచర్య తనిఖీలు

  • Inspect the pump and plumbing for leaks, especially at connections.
  • Check for unusual noises or vibrations during operation, which may indicate a problem.
  • Ensure the pump's ventilation openings are clear of debris to prevent overheating.

4.2 శీతాకాలం

In regions subject to freezing temperatures, it is crucial to properly winterize the pump to prevent damage:

  1. పంపుకు శక్తిని డిస్‌కనెక్ట్ చేయండి.
  2. Drain all water from the pump casing by removing the drain plug.
  3. Disconnect the intake and discharge pipes and drain them thoroughly.
  4. Store the pump in a dry, frost-free location if possible. If not, ensure all water is completely removed and consider using RV antifreeze in the pump casing if recommended by a professional.

5. ట్రబుల్షూటింగ్

This section provides general guidance for common issues. For complex problems, consult a qualified technician or contact Red Lion customer support.

5.1 Pump Does Not Start

  • శక్తి లేదు: Check circuit breaker or fuse. Ensure power cord is securely plugged in.
  • సరికాని వాల్యూమ్tagఇ సెట్టింగ్: Verify the pump's voltage setting matches the power supply (115V or 230V).
  • మోటార్ ఓవర్‌లోడ్: Allow the motor to cool down if the thermal overload protector has tripped. Check for obstructions in the impeller.

5.2 Pump Runs But Delivers No Water or Low Pressure

  • ప్రధాన నష్టం: Re-prime the pump as described in Section 2.2. Check for air leaks in the suction line or loose connections.
  • Clogged Intake/Impeller: Inspect the intake screen and impeller for debris.
  • Low Water Source: Ensure the water source level is adequate for the pump's suction lift capabilities.
  • Discharge Obstruction: Check for closed valves or blockages in the discharge piping or sprinkler heads.

5.3 Excessive Noise or Vibration

  • వ్యవస్థలో గాలి: Ensure the pump is fully primed and there are no air leaks.
  • వదులుగా మౌంటు చేయడం: Check that the pump is securely mounted to a stable surface.
  • Foreign Object: Turn off power and inspect the impeller for any foreign objects.

6. స్పెసిఫికేషన్లు

Detailed technical specifications for the Red Lion RL-SPRK100 Sprinkler Pump.

Red Lion RL-SPRK100 Sprinkler Pump Dimensions

Image 6.1: Technical drawing illustrating the dimensions of the SPRK Series Sprinkler Pumps, including height (A), length (B), and width (C).

స్పెసిఫికేషన్విలువ
బ్రాండ్ఎర్ర సింహం
మోడల్ సంఖ్య97101001
అశ్వశక్తి1 HP
వాల్యూమ్tage115/230 వోల్ట్లు
వాట్tage4848 వాట్స్
గరిష్ట ప్రవాహం రేటునిమిషానికి 63 గ్యాలన్లు (GPM)
గరిష్ట ఒత్తిడి45 PSI
గరిష్ట లిఫ్టింగ్ ఎత్తు25 అడుగులు
Intake Thread Size2-inch Female NPT
Discharge Thread Size1.5-inch Female NPT
మెటీరియల్Cast Iron, Thermoplastic
ఉత్పత్తి కొలతలు (L x W x H)21.85" x 11.42" x 10.2"
వస్తువు బరువు53 పౌండ్లు
శక్తి మూలంకార్డెడ్ ఎలక్ట్రిక్
చేర్చబడిన భాగాలుPump with thermoplastic impeller
UPC010121124868, 010121001398

7. వారంటీ మరియు మద్దతు

7.1 తయారీదారు వారంటీ

The Red Lion RL-SPRK100 Sprinkler Pump is covered by a 2-సంవత్సరం తయారీదారు వారంటీ. Please retain your proof of purchase for warranty claims. For specific terms and conditions, refer to the warranty information provided with your product packaging.

7.2 సాంకేతిక మద్దతు

For technical assistance, troubleshooting guidance, or questions regarding your Red Lion product, please contact our support team:

  • సాంకేతిక మద్దతు ఫోన్: 1-888-885-9254

Our staff are available to assist with troubleshooting or installation assistance.

సంబంధిత పత్రాలు - 97101001

ముందుగాview రెడ్ లయన్ RL-SPRK సిరీస్ స్ప్రింక్లర్ పంప్ ఓనర్స్ మాన్యువల్ - ఇన్‌స్టాలేషన్, ఆపరేషన్, మెయింటెనెన్స్ గైడ్
ఈ మాన్యువల్ రెడ్ లయన్ RL-SPRK సిరీస్ స్ప్రింక్లర్ పంపుల కోసం సమగ్ర సూచనలను అందిస్తుంది, ఇన్‌స్టాలేషన్‌ను కవర్ చేస్తుంది, వాల్యూమ్.tagఇ సెట్టింగ్‌లు, ఆపరేషన్, నిర్వహణ, ట్రబుల్షూటింగ్ మరియు భర్తీ భాగాలు. నివాస మరియు వాణిజ్య లాన్ మరియు టర్ఫ్ స్ప్రింక్లర్ వ్యవస్థల కోసం రూపొందించబడింది.
ముందుగాview రెడ్ లయన్ పంప్ ట్రబుల్షూటింగ్ గైడ్: జెట్, సబ్మెర్సిబుల్ మరియు ట్రాన్స్ఫర్ పంపులకు పరిష్కారాలు
రెడ్ లయన్ వాటర్ పంపుల కోసం సమగ్ర ట్రబుల్షూటింగ్ గైడ్, వీటిలో షాలో వెల్ జెట్ పంపులు (ఉదా. RJS-50-PREM), కన్వర్టిబుల్ జెట్ పంపులు (ఉదా. RJC-50), 4" సబ్‌మెర్సిబుల్ వెల్ పంపులు (ఉదా. RL12G10-3W2V), సబ్‌మెర్సిబుల్ యుటిలిటీ & సంప్ పంపులు, RL-S కాస్ట్ ఐరన్ సర్ఫేస్ ఎఫ్లూయెంట్ పంపులు, RL-50 ట్రాన్స్‌ఫర్ పంపులు మరియు RLSP/RLHE స్ప్రింక్లర్ పంపులు ఉన్నాయి. మోటార్ వైఫల్యం, ప్రైమింగ్ సమస్యలు, అల్ప పీడనం మరియు మరిన్ని వంటి సాధారణ సమస్యలకు పరిష్కారాలను కనుగొనండి.
ముందుగాview Red Lion RLHE-300 Cast Iron Industrial Sprinkler Pump Owner's Manual
Comprehensive owner's manual for the Red Lion RLHE-300 industrial sprinkler pump, covering installation, operation, maintenance, and troubleshooting. Features include heavy-duty iron casing, high-efficiency impeller, and automatic thermal protector.
ముందుగాview రెడ్ లయన్ CUB5 మినియేచర్ ఎలక్ట్రానిక్ 8-అంకెల డ్యూయల్ కౌంటర్ మరియు రేట్ ఇండికేటర్
రెడ్ లయన్ CUB5 మినీయేచర్ ఎలక్ట్రానిక్ 8-అంకెల డ్యూయల్ కౌంటర్ మరియు రేట్ ఇండికేటర్ కోసం వివరణాత్మక స్పెసిఫికేషన్లు, ఇన్‌స్టాలేషన్ గైడ్ మరియు ప్రోగ్రామింగ్ మాన్యువల్. ఎంచుకోదగిన LCD లేదా LED బ్యాక్‌లైటింగ్, ఐచ్ఛిక రిలే మరియు సీరియల్ కమ్యూనికేషన్ మాడ్యూల్స్ మరియు NEMA 4X/IP65 సీలింగ్ వంటి ఫీచర్లు ఉన్నాయి.
ముందుగాview Red Lion RJSE-75SS Sprinkler Utility Pump - Operation and Maintenance Manual
Comprehensive guide for the Red Lion RJSE-75SS Sprinkler Utility Pump, covering safety warnings, electrical precautions, application, installation, operation, maintenance, and troubleshooting. Includes detailed diagrams and warranty information.
ముందుగాview Red Lion RL-MP25A Utility Pump Owner's Manual and Specifications
Comprehensive owner's manual for the Red Lion RL-MP25A Utility Pump, detailing specifications, safety instructions, installation, operation, maintenance, and troubleshooting. Includes flow rate charts and technical data.