SDC CB402-B

SDC CB402-B Emergency Door Release and Bathroom Control Instruction Manual

Model: CB402-B

1. పరిచయం

This manual provides detailed instructions for the installation, operation, and maintenance of the SDC CB402-B Communicating Bathroom Control and Emergency Access Switch. Please read this manual thoroughly before installation and use to ensure proper function and safety.

2. ఉత్పత్తి ముగిసిందిview

The SDC CB402-B is a panel-mounted control switch designed for bathroom lock systems, providing both locking/unlocking functionality and emergency access. It features a clear indicator light for lock status.

SDC CB402-B Emergency Door Release and Bathroom Control Switch

Figure 1: SDC CB402-B Control Panel
This image displays the SDC CB402-B control panel. The panel is rectangular, silver-colored, and features the "SDC" logo at the top. Below the logo, text reads "BATHROOM LOCK" and "BOTH DOORS MUST BE CLOSED TO LOCK". A prominent red square button is located in the center. Below the button, text indicates "PUSH TO LOCK OR UNLOCK" and "LIGHT ON DOOR LOCKED". There are also two visible screws for mounting.

ముఖ్య లక్షణాలు:

  • Integrated lock/unlock button.
  • Visual indicator for door lock status.
  • Designed for bathroom lock applications requiring two doors to be closed for locking.
  • Panel mount design for secure installation.

3. సెటప్ మరియు ఇన్‌స్టాలేషన్

ముఖ్యమైన భద్రతా సమాచారం: Installation should only be performed by qualified personnel in accordance with all local electrical codes and regulations. Disconnect power before beginning installation.

  1. మౌంటు స్థానం: Select a suitable indoor location for panel mounting, typically adjacent to the door frame or on a wall within easy reach.
  2. వైరింగ్: The CB402-B requires electrical connections for power and communication with the locking mechanism. Refer to the wiring diagram provided with your specific lock system for correct connections. Ensure all connections are secure and insulated. The unit utilizes an X-10 connectivity protocol for communication, which must be integrated with a compatible system.
  3. ప్యానెల్ మౌంటు:
    • Prepare the wall opening according to the dimensions specified in the product packaging.
    • Feed the necessary wiring through the opening.
    • Secure the CB402-B panel to the wall using appropriate screws (as shown in Figure 1). Do not overtighten.
  4. సిస్టమ్ ఇంటిగ్రేషన్: Connect the CB402-B to your bathroom lock system and power supply as per the system's instructions. Verify all connections before restoring power.
  5. ప్రారంభ పరీక్ష: After installation, restore power and perform a functional test to ensure the lock/unlock button and status indicator light operate correctly.

4. ఆపరేషన్

The SDC CB402-B is designed for straightforward operation:

  • తలుపు లాక్ చేయడం: To lock the bathroom door(s), ensure "BOTH DOORS MUST BE CLOSED TO LOCK" as indicated on the panel. Press the red square button labeled "PUSH TO LOCK OR UNLOCK".
  • తలుపును అన్‌లాక్ చేయడం: To unlock the bathroom door(s), press the red square button again.
  • స్థితి సూచిక: The panel includes a light indicator. When the "LIGHT ON DOOR LOCKED" is illuminated, it signifies that the door(s) are securely locked.

5. నిర్వహణ

The SDC CB402-B requires minimal maintenance to ensure continued reliable operation:

  • శుభ్రపరచడం: Periodically wipe the surface of the control panel with a soft, dry cloth. Avoid using abrasive cleaners or solvents, which can damage the finish or internal components.
  • తనిఖీ: Regularly inspect the panel for any signs of physical damage, loose connections, or wear.
  • కార్యాచరణ తనిఖీ: Periodically test the lock/unlock function and the status indicator light to ensure they are working correctly.

6. ట్రబుల్షూటింగ్

If you encounter issues with your SDC CB402-B, consider the following:

  • బటన్ స్పందించడం లేదు:
    • Check if the power supply to the unit and the associated lock system is active.
    • Verify all wiring connections are secure and correct according to the installation diagram.
    • Ensure both doors are fully closed if the system requires this condition for locking.
  • Status Light Not Illuminating:
    • Confirm the door is actually locked.
    • Check power supply and wiring.
    • If the light is still not working, the indicator bulb or LED may need replacement, or there might be an internal fault. Contact SDC support.
  • అడపాదడపా ఆపరేషన్: This could indicate loose wiring or an issue with the X-10 communication. Re-check all connections and ensure there is no interference with the X-10 signal.

For persistent issues, contact SDC technical support.

7. స్పెసిఫికేషన్లు

స్పెసిఫికేషన్వివరాలు
మోడల్CB402-B
బ్రాండ్SDC (Security Door Controls)
వస్తువు బరువు1 పౌండ్
మౌంటు రకంప్యానెల్ మౌంట్
కనెక్టివిటీ ప్రోటోకాల్X-10
యూనిట్ కౌంట్1 కౌంట్
కొలతలు2-7/8 inches W (Width) - Other dimensions not specified.

8. వారంటీ మరియు మద్దతు

For information regarding the product warranty, please refer to the official SDC (Security Door Controls) website or contact their customer service directly. Warranty terms and conditions may vary.

For technical support or further assistance, please visit the SDC Security webసైట్ or contact their authorized distributors.

సంబంధిత పత్రాలు - CB402-B

ముందుగాview SDC CB సిరీస్ కమ్యూనికేటింగ్ బాత్రూమ్ స్విచ్ ఇన్‌స్టాలేషన్ సూచనలు
CB400-A, CB400-B, మరియు CB700 మోడళ్లతో సహా SDC CB సిరీస్ కమ్యూనికేటింగ్ బాత్రూమ్ స్విచ్‌ల కోసం వివరణాత్మక ఇన్‌స్టాలేషన్ సూచనలు. డోర్ యాక్సెస్ కంట్రోల్ కోసం స్పెసిఫికేషన్లు, వైరింగ్ మరియు అసెంబ్లీ విధానాలను కవర్ చేస్తుంది.
ముందుగాview SDC 492 పుల్ స్టేషన్ ఎమర్జెన్సీ డోర్ రిలీజ్ ఇన్‌స్టాలేషన్ సూచనలు
SDC 492 పుల్ స్టేషన్ ఎమర్జెన్సీ డోర్ రిలీజ్ కోసం వివరణాత్మక ఇన్‌స్టాలేషన్ గైడ్, సెటప్, గ్లాస్ రాడ్ రీప్లేస్‌మెంట్, వైరింగ్ మరియు ఎలక్ట్రికల్ స్పెసిఫికేషన్‌లను కవర్ చేస్తుంది. మోడల్ నంబర్‌లు మరియు సంప్రదింపు సమాచారం ఉన్నాయి.
ముందుగాview SDC 491 ఎమర్జెన్సీ డోర్ రిలీజ్ ఇన్‌స్టాలేషన్ సూచనలు
SDC 491 బ్రేక్ గ్లాస్ ఎమర్జెన్సీ డోర్ రిలీజ్ కోసం ఇన్‌స్టాలేషన్ సూచనలు, దాని లక్షణాలు, మౌంటు ఎంపికలు మరియు ఫెయిల్-సేఫ్ ఎలక్ట్రిక్ లాక్ సిస్టమ్‌ల కోసం వైరింగ్ రేఖాచిత్రాన్ని వివరిస్తాయి.
ముందుగాview SDC 474MU Touchless Sense Switch Installation Instructions
Comprehensive installation guide for the SDC 474MU Touchless Sense Switch with Manual Override Button, covering features, specifications, and detailed wiring diagrams for access control systems.
ముందుగాview SDC 352 నారో లైన్ EMLock ఇన్‌స్టాలేషన్ సూచనలు
SDC 352 నారో లైన్ ఎలక్ట్రోమాగ్నెటిక్ లాక్ కోసం సమగ్ర ఇన్‌స్టాలేషన్ గైడ్. 12VDC లేదా 24VDC సిస్టమ్‌ల కోసం ఈ యాక్సెస్ కంట్రోల్ హార్డ్‌వేర్‌ను ఎలా సరిగ్గా ఇన్‌స్టాల్ చేయాలో మరియు వైర్ చేయాలో తెలుసుకోండి.
ముందుగాview SDC 413N & 423 పుష్ స్విచ్ ఇన్‌స్టాలేషన్ సూచనలు
సర్దుబాటు చేయగల 1-60 సెకన్ల సమయం ఆలస్యంతో SDC 413N మరియు 423 పుష్ స్విచ్‌ల కోసం ఇన్‌స్టాలేషన్ సూచనలు. ఫెయిల్-సేఫ్ మరియు ఫెయిల్-సేఫ్ కాన్ఫిగరేషన్‌ల కోసం వైరింగ్ రేఖాచిత్రాలు, ఎలక్ట్రికల్ స్పెసిఫికేషన్‌లు మరియు UL 294 పనితీరు రేటింగ్‌లు ఉన్నాయి.