This manual provides essential information for the safe and effective use of the GE SELA36AT0150 Bolt-On Mount Type SEL Molded Case Circuit Breaker. This current-limiting circuit breaker is designed for industrial and commercial applications, providing protection against overcurrents and short circuits.
ముఖ్య లక్షణాలు ఉన్నాయి:
- Current Limiting Circuit Breaker: Designed to limit the magnitude and duration of short-circuit currents.
- 150 Amps Max | 150 A Rating Plug: Configured for a maximum current of 150 Amps with a corresponding rating plug.
- 3 Pole, 480/600 VAC: Suitable for three-phase alternating current systems up to 600 Volts.
- Spectra RMS Series: Part of the GE Spectra RMS line, known for advanced protection features.
- Bolt-On Mount: Designed for secure bolt-on installation.

మూర్తి 1: ముందు view of the GE SELA36AT0150 Circuit Breaker, showing the ON/OFF switch and product labels.
2. భద్రతా సమాచారం
హెచ్చరిక: Installation, maintenance, and troubleshooting of electrical equipment should only be performed by qualified and licensed electricians. Failure to follow these instructions can result in serious injury, death, or property damage.
- Always disconnect power before working on electrical circuits or equipment.
- Use appropriate personal protective equipment (PPE), including insulated gloves and eye protection.
- Verify all connections are secure and properly torqued according to specifications.
- Ensure the circuit breaker's ratings match the system requirements.
3. సెటప్ మరియు ఇన్స్టాలేషన్
The GE SELA36AT0150 is a bolt-on mount circuit breaker. Proper installation is crucial for safe and reliable operation.
3.1 ప్రీ-ఇన్స్టాలేషన్ తనిఖీలు
- Confirm the circuit breaker's voltage, current, and interrupting ratings are compatible with the electrical system.
- Inspect the circuit breaker for any physical damage. Do not install damaged units.
- మౌంటు ఉపరితలం శుభ్రంగా, పొడిగా మరియు నిర్మాణాత్మకంగా దృఢంగా ఉందని నిర్ధారించుకోండి.
3.2 మౌంటు సూచనలు
- De-energize the electrical panel or system where the breaker will be installed. Verify zero voltagఇ మల్టీమీటర్తో.
- Position the circuit breaker in the designated slot or mounting location.
- Secure the breaker using appropriate bolts and hardware for bolt-on mounting. Ensure it is firmly seated.
- Connect the load and line conductors to the appropriate terminals. The breaker includes a set of bottom lugs.
- Refer to the product label for specific wire ranges and torque specifications:
- Wire Range: #12 - 3/0 CU, #12 - 3/0 AL
- Torque: #12-#10: 35 lb-in, #8-#3: 100 lb-in, #2-3/0: 150 lb-in
- Double-check all connections for tightness and proper insulation.

Figure 2: Close-up of the circuit breaker's main label, detailing Cat No., Amp rating, Voltage, Pole configuration, Rating Plug Type, Lug Data, Wire Range, and Torque specifications.

Figure 3: Close-up of the circuit breaker's interrupting rating label, showing RMS Symmetrical Amps at various voltages (240V, 480V, 600V) and international standards.

చిత్రం 4: వెనుక view of the GE SELA36AT0150 Circuit Breaker, showing the bolt-on mounting points and terminal connections.
4. ఆపరేటింగ్ సూచనలు
The GE SELA36AT0150 circuit breaker is designed for simple operation, primarily acting as an ON/OFF switch and an automatic protective device.
4.1 ఆన్/ఆఫ్ చేయడం
- To turn the circuit ON, firmly push the handle to the "ON" position.
- To turn the circuit ఆఫ్, firmly push the handle to the "OFF" position.
4.2 Tripping and Resetting
If an overcurrent or short circuit condition occurs, the breaker will automatically "trip" to the center position (between ON and OFF) to protect the circuit. To reset a tripped breaker:
- First, move the handle completely to the "OFF" position. This resets the internal mechanism.
- Investigate and resolve the cause of the trip (e.g., overloaded circuit, short circuit).
- Once the issue is resolved, firmly push the handle to the "ON" position to restore power.
- If the breaker immediately trips again, do not attempt to reset it repeatedly. Consult a qualified electrician.
5. నిర్వహణ
సర్క్యూట్ బ్రేకర్లకు సాధారణంగా కనీస నిర్వహణ అవసరం. అయితే, నిరంతర సురక్షితమైన ఆపరేషన్ను నిర్ధారించడానికి కాలానుగుణంగా తనిఖీ చేయడం సిఫార్సు చేయబడింది.
- దృశ్య తనిఖీ: Annually inspect the breaker for signs of physical damage, discoloration, or loose connections.
- శుభ్రపరచడం: Keep the area around the breaker clean and free of dust and debris. Use a dry, non-conductive cloth for cleaning. Do not use liquids.
- కనెక్షన్ తనిఖీలు: Periodically (e.g., every 3-5 years, or as per local codes) have a qualified electrician check the tightness of terminal connections.
- పరీక్ష: For critical applications, periodic testing of the breaker's trip mechanism by a qualified professional may be required.
గమనిక: Do not attempt to open or repair the circuit breaker. There are no user-serviceable parts inside.
6. ట్రబుల్షూటింగ్
ఈ విభాగం మీ సర్క్యూట్ బ్రేకర్తో మీరు ఎదుర్కొనే సాధారణ సమస్యలను పరిష్కరిస్తుంది.
| సమస్య | సాధ్యమైన కారణం | పరిష్కారం |
|---|---|---|
| తరచుగా బ్రేకర్ ట్రిప్పులు. | Overloaded circuit, short circuit, ground fault, or faulty appliance. | Reduce load on the circuit. Unplug appliances. Inspect wiring for damage. If problem persists, consult a qualified electrician. |
| బ్రేకర్ రీసెట్ చేయబడదు. | Persistent fault (short circuit/overload) or internal breaker damage. | Ensure the handle is pushed fully to "OFF" before attempting to reset. If it still won't reset, do not force it. Call a qualified electrician. |
| సర్క్యూట్ కు విద్యుత్ లేదు, కానీ బ్రేకర్ ఆన్ లో ఉంది. | Loose connection, wiring issue, or internal breaker failure. | This indicates a serious issue. Immediately turn off the breaker and consult a qualified electrician. Do not attempt to diagnose or fix yourself. |
For any issues not covered here, or if troubleshooting steps do not resolve the problem, always contact a qualified and licensed electrician.
7. స్పెసిఫికేషన్లు
Detailed technical specifications for the GE SELA36AT0150 Circuit Breaker:
| గుణం | విలువ |
|---|---|
| మోడల్ సంఖ్య | SELA36AT0150 |
| బ్రాండ్ | జనరల్ ఎలక్ట్రిక్ |
| ప్రస్తుత రేటింగ్ | 150 Amps |
| వాల్యూమ్tagఇ రేటింగ్ | 480 / X VAX |
| పోల్స్ సంఖ్య | 3 |
| సర్క్యూట్ బ్రేకర్ రకం | Standard, Current Limiting, Molded Case |
| మౌంటు రకం | బోల్ట్-ఆన్ మౌంట్ |
| Interrupting Rating @ 240 VAC | 100,000 Amps |
| Interrupting Rating @ 480 VAC | 65,000 Amps |
| Interrupting Rating @ 600 VAC | 25,000 Amps |
| Rating Plug Type | SRPE150A |
| Rating Plug Inst. Adjustable Range | 450-1991 A (Lo to Hi) |
| ఉత్పత్తి కొలతలు (D x W x H) | 4" x 4" x 6.5" (సుమారుగా) |
| బరువు | 4.8 పౌండ్లు (సుమారు) |
| మొదటి తేదీ అందుబాటులో ఉంది | అక్టోబర్ 11, 2012 |
8. వారంటీ మరియు మద్దతు
For specific warranty information regarding your GE SELA36AT0150 Circuit Breaker, please refer to the documentation provided at the time of purchase or contact General Electric directly. As a general guideline, electrical components typically come with a manufacturer's warranty covering defects in materials and workmanship.
For technical support, service, or to inquire about replacement parts, please contact General Electric customer service or visit their official webసైట్. మీరు కూడా సందర్శించవచ్చు అమెజాన్లో GE స్టోర్ for more information on GE products.
Always ensure that any work on electrical systems is performed by qualified and licensed professionals.
9. అధికారిక ఉత్పత్తి వీడియోలు
No official product videos from the seller were found for this specific model in the provided data. For general product information or installation guides, please check the manufacturer's official webసైట్ లేదా అధీకృత పంపిణీదారులు.