పరిచయం
This manual provides detailed instructions for the installation, setup, and operation of your Leviton Decora Motion Sensor In-Wall Switch (Model IPS02-1LW). This device is designed to automatically turn lights ON when motion is detected and OFF when the room is vacated, offering convenience and energy savings. Please read all instructions carefully before beginning installation.
ముఖ్యమైన భద్రతా సమాచారం
WARNING: TO AVOID FIRE, SHOCK OR DEATH; TURN OFF THE POWER AT THE CIRCUIT BREAKER OR FUSE AND TEST THAT POWER IS OFF BEFORE WIRING.
- ఇన్స్టాలేషన్ దాదాపు 15 నిమిషాలు పడుతుంది.
- The wiring device shown in this video may be different from the one you are installing.
- This device may be used with copper or copper-clad wire only.
- For use with #12 AWG through #14 AWG wire.
- If you are unsure about any part of the instructions or are uncomfortable, contact a qualified electrician.
అవసరమైన సాధనాలు
Ensure you have the following tools on hand before beginning installation:
- ఫ్లాట్ హెడ్ స్క్రూడ్రైవర్
- ఫిలిప్స్ హెడ్ స్క్రూడ్రైవర్
- మినీ ఫ్లాట్ హెడ్ స్క్రూడ్రైవర్
- Electrician's Pliers
- వైర్ స్ట్రిప్పర్
- ఎలక్ట్రికల్ టేప్
- Handheld Voltagఇ టెస్టర్
ఇన్స్టాలేషన్ సూచనలు
1. సంస్థాపన కోసం సిద్ధం
- పవర్ ఆఫ్ చేయండి: Locate the circuit breaker or fuse that controls the power to the switch you are replacing. Turn it OFF.
- పవర్ ఆఫ్ అయిందని ధృవీకరించండి: Use a handheld voltage tester to confirm that the power is completely off at the switch box. Test all wires.
- Identify Hot Wire: Turn the circuit breaker back ON briefly. Carefully use the voltage tester to identify the hot wire (the tester will indicate voltage). Once identified, immediately turn the circuit breaker OFF again and re-test to ensure power is off. Label the hot wire with a small piece of electrical tape for easy identification.
- Identify Load and Ground Wires: In a typical wall box for this device, you will find one black wire (hot), a bare copper wire (ground), and another black wire (load). The color of wires can vary; if unsure, consult an electrician.
- వైర్లను సిద్ధం చేయండి: Ensure wires are straight and stripped according to the strip gauge located on the back of the device.
2. Wiring the Motion Sensor Switch
The IPS02-1LW switch offers the option of either wrapping leads around the terminal screws or using an external back-wire clamp. This guide demonstrates back-wiring.
- Connect Load Wire: Connect the load wall box wire to the terminal screw marked "RD" (Red).
- Connect Hot Wire: Connect the line hot wall box wire to the terminal screw marked "BK" (Black).
- గ్రౌండ్ వైర్ కనెక్ట్ చేయండి: Connect the green or bare copper wire in the wall box to the green terminal screw on the device.
- న్యూట్రల్ వైర్: Neutral wires are NOT required for this installation and should be capped off and placed back into the wall box if present.
3. పరికరాన్ని మౌంట్ చేయడం
- పరికరం కోసం అవుట్లెట్ వాల్ బాక్స్లో గదిని అందించడానికి అన్ని వైర్లను ఉంచండి.
- Ensure the word "TOP" is facing up on the device.
- Partially screw in the mounting screws into the wall box mounting holes.
4. ఇన్స్టాలేషన్ వీడియో గైడ్
This video demonstrates the installation process for Leviton IPS02, IPS05, IPS06 Occupancy Sensors and IPV02, IPV05 Vacancy Sensors, including wiring and initial setup steps. It covers identifying wires, making connections, and mounting the device.
5. ఉత్పత్తి చిత్రాలు
ఆపరేటింగ్ సూచనలు
1. Initial Power-Up and Testing
- సర్క్యూట్ బ్రేకర్ లేదా ఫ్యూజ్ వద్ద శక్తిని పునరుద్ధరించండి.
- For IPS02 (Occupancy Sensor): Lights will automatically turn ON after power is applied.
- For IPV02/IPV05 (Vacancy Sensor): Press and release the push pad to turn the lights ON.
2. Adjusting Time-Out and Light Sensitivity
To access the adjustment dials, gently remove the face cover of the sensor.
- సమయ ఎంపిక: Use a mini flathead screwdriver to turn the Time Selection dial.
- Position '0' = 30 seconds (recommended for testing)
- Position '1' = 5 minutes
- Position '2' = 15 minutes
- Position '3' = 30 minutes
- కాంతి స్థాయి సర్దుబాటు: Use a mini flathead screwdriver to turn the Light Level Adjustment dial.
- Turn clockwise for lights to turn ON in lighter conditions (higher sensitivity).
- Turn counter-clockwise for lights to turn ON in less light conditions (lower sensitivity).
- For Vacancy Sensors (IPV series), light level sensitivity does not apply as they are manual-on.
After adjusting, replace the face cover.
3. Final Mounting
- Tighten the mounting screws into the wall box.
- వాల్ ప్లేట్ అటాచ్ చేయండి.
- సర్క్యూట్ బ్రేకర్ వద్ద శక్తిని పునరుద్ధరించండి.
స్పెసిఫికేషన్లు
| ఫీచర్ | వివరాలు |
|---|---|
| బ్రాండ్ | లెవిటన్ |
| మోడల్ సంఖ్య | IPS02-1LW |
| రంగు | తెలుపు |
| శక్తి మూలం | కార్డెడ్ ఎలక్ట్రిక్ |
| వస్తువు బరువు | 3.2 ఔన్సులు |
| గరిష్ట పరిధి | 900 sq. ft. (180-degree field-of-view) |
| మౌంటు రకం | వాల్ స్విచ్ |
| అనుకూల పరికరాలు | Fan, Light (Incandescent, CFL, LED, electronic low voltage, magnetic low voltage loads) |
| స్విచ్ రకం | 1-way (Single Pole) |
| ప్రత్యేక లక్షణాలు | Motion Sensor, Auto-On/Auto-Off, No Neutral Wire Required |
ట్రబుల్షూటింగ్
- Lights do not turn off after 30 seconds (IPV Series): If lights do not turn off 30 seconds after leaving the room, decrease the sensitivity of the sensor.
- Lights do not turn on (IPS Series): If lights do not turn on automatically when you step back into the room, increase the sensitivity of the sensor.
- సాధారణ సమస్యలు: If lights do not turn on or off as expected, refer to the troubleshooting section of the instructions provided with the product for detailed guidance. This may include checking wiring connections, bulb compatibility, or sensor placement.
వారంటీ సమాచారం
The Leviton Decora Motion Sensor In-Wall Switch (IPS02-1LW) comes with a 5-సంవత్సరం పరిమిత వారంటీ.
మద్దతు
అదనపు మద్దతు, ఉత్పత్తి సమాచారం కోసం, లేదా view other Leviton products, please visit the official Leviton webసైట్ లేదా వారి కస్టమర్ సేవను సంప్రదించండి.
You can find more information about Leviton sensors at leviton.com/sensors.