YSI 251401Y

YSI 251401Y DPD ఉచిత క్లోరిన్ రీజెంట్ పౌడర్ యూజర్ మాన్యువల్

For pHotoFlex and 900 Chlorine Colorimeter

1. ఉత్పత్తి ముగిసిందిview

The YSI 251401Y DPD Free Chlorine Reagent Powder is an EPA-approved chemical reagent designed for accurate measurement of free chlorine concentrations. This product is specifically formulated for use with YSI pHotoFlex and 900 Chlorine Colorimeter instruments, providing reliable results within a range of 0.02 to 2 mg/L. Each pack contains 100 individual 10ml volume powder packets, ensuring convenience and consistent dosing for laboratory and field applications.

YSI 251401Y DPD Free Chlorine Reagent Powder Packet

Image 1.1: A single packet of YSI 251401Y DPD Free Chlorine Reagent Powder. The label indicates "Powder Packets," "Part Number: 251401Y," "Lot Code: L 01 A," and "Exp: 01.2017." It also includes safety warnings and manufacturer contact information.

2. Safety Information and Handling

This product is intended for professional laboratory and field use only. Adherence to all safety guidelines is critical for proper and safe operation.

3. సెటప్ మరియు తయారీ

Before beginning any measurement, ensure you have the necessary equipment and that your colorimeter is calibrated according to its specific user manual.

3.1 Required Materials (Not Included)

3.2 రీజెంట్ తయారీ

The YSI 251401Y DPD Free Chlorine Reagent is provided in pre-measured powder packets, eliminating the need for manual weighing or dilution. Each packet contains the precise amount of reagent for a 10ml sampలే వాల్యూమ్.

4. Operating Instructions for Free Chlorine Measurement

Follow these steps for accurate free chlorine measurement using the YSI 251401Y DPD Free Chlorine Reagent Powder with a compatible YSI colorimeter.

  1. S సిద్ధం చేయండిampలె సెల్: Rinse a clean sample cell thoroughly with deionized water, then with a small amount of the sampపరీక్షించబడాలి.
  2. ఫిల్ ఎస్ampలె సెల్: లను పూరించండిample cell with 10 ml of the water sample to be analyzed. Ensure the sample volume is precise.
  3. రియాజెంట్‌ను జోడించండి: Carefully open one YSI 251401Y DPD Free Chlorine Reagent Powder packet. Add the entire contents of the powder packet to the 10 ml sampసెల్ లో లే.
  4. మిక్స్: క్యాప్ ది ఎస్ample cell and invert it gently several times to dissolve the powder completely. Avoid shaking vigorously, which can introduce air bubbles. A pink color will develop if free chlorine is present.
  5. ప్రతిచర్య సమయం: Allow a reaction time of approximately 1 minute for the color to fully develop. Consult your colorimeter's manual for specific reaction time recommendations.
  6. కొలత: Insert the prepared sample cell into the YSI pHotoFlex or 900 Chlorine Colorimeter. Follow the instrument's instructions to initiate the measurement. The colorimeter will display the free chlorine concentration in mg/L.
  7. రికార్డు ఫలితాలు: Record the measurement results immediately.
  8. శుభ్రపరచడం: After measurement, empty the sample cell and rinse it thoroughly with deionized water.

గమనిక: For best results, perform measurements promptly after sample collection. The DPD method is sensitive to light and temperature; protect samples and reagents from direct sunlight and extreme temperatures.

5. నిర్వహణ మరియు నిల్వ

Proper storage of the reagent packets is essential to maintain their integrity and ensure accurate results.

6. ట్రబుల్షూటింగ్

This section addresses common issues that may arise during the use of the DPD Free Chlorine Reagent.

సమస్యసాధ్యమైన కారణంపరిష్కారం
No color development or faint color when chlorine is expected.
  • Expired reagent.
  • Insufficient mixing.
  • Sample pH outside optimal range.
  • Interfering substances in sample.
  • Check expiration date; use fresh reagent.
  • Ensure complete dissolution of powder.
  • ధృవీకరించండిample pH is within the colorimeter's specified range for DPD method.
  • Consult colorimeter manual for known interferences.
Inconsistent or erratic readings.
  • సరికాని రుampలే వాల్యూమ్.
  • కలుషితమైన రుample కణాలు.
  • s లో గాలి బుడగలుample సెల్.
  • Colorimeter calibration issue.
  • Ensure precise 10 ml sampలే వాల్యూమ్.
  • Thoroughly clean sample cells before each use.
  • Gently invert to mix, avoid vigorous shaking.
  • Perform colorimeter calibration as per instrument manual.

7. స్పెసిఫికేషన్లు

8. వారంటీ మరియు మద్దతు

For technical support, product inquiries, or to request a Safety Data Sheet (SDS), please contact YSI directly using the information below.

YSI stands behind the quality of its products. Please refer to the official YSI website or contact customer support for detailed warranty information applicable to this reagent.

సంబంధిత పత్రాలు - 251401Y

ముందుగాview YSI మోడల్ 32 కండక్టెన్స్ మీటర్ ఇన్‌స్ట్రక్షన్ మాన్యువల్
YSI మోడల్ 32 కండక్టెన్స్ మీటర్ కోసం సూచనల మాన్యువల్, దాని సాధారణ వివరణ, స్పెసిఫికేషన్లు, ఆపరేటింగ్ విధానాలు, నిర్వహణ మరియు క్రమాంకనం గురించి వివరిస్తుంది.
ముందుగాview YSI Pro20/Pro20i త్వరిత ప్రారంభ మార్గదర్శి: అమరిక మరియు ఆపరేషన్
Concise guide for calibrating and operating the YSI Pro20/Pro20i dissolved oxygen meters, covering membrane installation, sensor setup, barometer and DO calibration, salinity compensation, and measurement taking. Includes essential operational steps and contact information.
ముందుగాview YSI 3821 బఫర్ సొల్యూషన్ pH 4.00 సేఫ్టీ డేటా షీట్ (SDS)
YSI 3821 బఫర్ సొల్యూషన్ pH 4.00 కోసం సమగ్ర భద్రతా డేటా షీట్ (SDS), ఉత్పత్తి గుర్తింపు, ప్రమాదాలు, కూర్పు, ప్రథమ చికిత్స, నిర్వహణ, నిల్వ మరియు నియంత్రణ సమాచారాన్ని వివరిస్తుంది.
ముందుగాview YSI EcoSense DO200A/DO200M కరిగిన ఆక్సిజన్ మరియు ఉష్ణోగ్రత పరికరాల వినియోగదారు మాన్యువల్
This user manual provides comprehensive instructions for operating, installing, maintaining, and troubleshooting the YSI EcoSense DO200A and DO200M dissolved oxygen and temperature instruments. It includes details on specifications, accessories, and warranty information.
ముందుగాview YSIT-1 Satellite Transmitter Operation and Maintenance Manual
Comprehensive user manual for the YSI Model YSIT-1 Satellite Transmitter, covering its operation, maintenance, hardware setup, and serial command reference. Details include time management, data storage, GOES data formatting, RF transmitter control, and GPS synchronization.
ముందుగాview YSI IQ Sensor Net MIQ/CHV PLUS Operating Manual
This operating manual provides detailed instructions for the YSI IQ Sensor Net MIQ/CHV PLUS valve module, covering installation, settings, maintenance, and safety guidelines for compressed air-operated sensor cleaning heads.