The Drayton ZA5 replacement actuator is designed for compatibility with the Drayton 22mm 2-port motorised valve, specifically part number 27100. This actuator is a critical component in central heating systems, responsible for controlling the flow of water to a specific heating zone by opening and closing the associated valve.

Drayton ZA5 Zone Valve Actuator with 5-wire cable

An image showing the Drayton ZA5 Zone Valve Actuator, a white rectangular unit with a label detailing its specifications, connected to a black cable with five colored wires (red, orange, green, blue, grey) at the end.

2. భద్రతా సమాచారం

Always prioritize safety when working with electrical and heating systems. Failure to follow these instructions could result in electric shock, fire, or personal injury.

  • WARNING: DISCONNECT SUPPLY BEFORE REMOVING COVER. Ensure the main electrical supply to the heating system is completely switched off at the consumer unit/fuse box before attempting any installation, maintenance, or removal of the actuator cover.
  • Installation should only be performed by a qualified electrician or heating engineer.
  • Do not operate the actuator if it appears damaged.
  • అన్ని వైరింగ్ కనెక్షన్లు సురక్షితంగా ఉన్నాయని మరియు స్థానిక విద్యుత్ కోడ్‌లకు అనుగుణంగా ఉన్నాయని నిర్ధారించుకోండి.
  • Keep the actuator dry and away from excessive moisture.

3 కీ ఫీచర్లు

  • Drayton Part Number: 27650
  • 5-Wire configuration for comprehensive control.
  • Direct replacement for the Drayton 27100 Motorised Valve actuator.
  • Designed for zone valve applications in central heating systems.

4. సాంకేతిక లక్షణాలు

స్పెసిఫికేషన్విలువ
బ్రాండ్డ్రేటన్
మోడల్ సంఖ్య27650
ఉత్పత్తి కొలతలు9.5 x 6 x 6 సెం.మీ
వస్తువు బరువు535 గ్రా
వాల్యూమ్tage230 వోల్ట్లు
ఫ్రీక్వెన్సీ50 Hz
విద్యుత్ వినియోగం6 వాట్స్
గరిష్టంగా పరిసర ఉష్ణోగ్రత52°C
Max. System Pressure125 psi
రేటింగ్ మారండి3(1)ఎ

5. ఇన్స్టాలేషన్ గైడ్

This section provides general guidance for replacing a Drayton ZA5 actuator. Always refer to the specific wiring diagrams provided with your heating system and consult a qualified professional if unsure.

అవసరమైన సాధనాలు:

  • స్క్రూడ్రైవర్ సెట్
  • వైర్ స్ట్రిప్పర్స్/కట్టర్లు
  • వాల్యూమ్tagఇ టెస్టర్

ఇన్‌స్టాలేషన్ దశలు:

  1. పవర్ ఆఫ్: Locate the main electrical supply to your central heating system and switch it off at the consumer unit/fuse box. Verify that power is off using a voltagఇ టెస్టర్.
  2. Access Actuator: Identify the existing actuator on your 2-port motorised valve. It is typically secured by screws or clips.
  3. వైరింగ్‌ను డిస్‌కనెక్ట్ చేయండి: Carefully note or photograph the existing wiring connections. Disconnect the five wires from the terminal block.
  4. పాత యాక్యుయేటర్‌ను తీసివేయండి: Unscrew or unclip the old actuator from the valve body. The valve body itself usually remains in place.
  5. కొత్త యాక్యుయేటర్‌ను ఇన్‌స్టాల్ చేయండి: Position the new Drayton ZA5 actuator onto the valve body, ensuring it aligns correctly. Secure it with the provided screws or clips.
  6. వైరింగ్ కనెక్ట్ చేయండి: Connect the five wires of the new actuator to the terminal block, matching the connections noted in step 3. The typical wire colors and functions are:
    • Brown: Live (Switched Live from programmer/thermostat)
    • నీలం: తటస్థ
    • ఆకుపచ్చ/పసుపు: భూమి
    • Orange: Switched Live (to boiler/pump)
    • Grey: Return (from valve microswitch)
  7. సురక్షిత కవర్: Ensure all wires are neatly tucked away and secure the actuator cover.
  8. శక్తిని పునరుద్ధరించండి: Switch the main electrical supply back on.
  9. పరీక్షా వ్యవస్థ: Test the heating system to ensure the actuator operates correctly, opening and closing the zone valve as commanded by the thermostat or programmer.

6. ఆపరేటింగ్ సూచనలు

The Drayton ZA5 actuator operates automatically as part of your central heating system. It does not require manual intervention for its primary function.

  • When the thermostat calls for heat in the zone controlled by the valve, the actuator receives an electrical signal, causing it to open the valve.
  • Once the thermostat's set temperature is reached, or the heating program ends, the electrical signal is removed, and the actuator closes the valve, typically via a spring return mechanism.
  • A small lever or button may be present on the actuator for manual override or to check valve operation during installation. Refer to your heating system's overall manual for specific instructions on using this feature, if available.

7. నిర్వహణ

The Drayton ZA5 actuator is designed to be maintenance-free under normal operating conditions. No user-serviceable parts are inside the unit.

  • Keep the exterior of the actuator clean and free from dust and debris. Use a dry cloth for cleaning.
  • Do not attempt to lubricate any internal components.
  • Periodically check the wiring connections for any signs of wear or looseness. Ensure power is off before inspecting connections.
  • If the actuator shows signs of damage or malfunction, it should be replaced by a qualified professional.

8. ట్రబుల్షూటింగ్

If you experience issues with your heating system that you suspect are related to the zone valve actuator, consider the following common problems and solutions:

సమస్యసాధ్యమైన కారణంపరిష్కారం
No heat in zoneActuator not opening valve; no power to actuator; faulty thermostat/programmer.Check thermostat setting. Verify power to actuator (with power off, check wiring). Replace actuator if it does not respond to power.
Zone always hot (heating won't turn off)Actuator stuck open; faulty microswitch in actuator; wiring fault.Check if actuator returns to closed position when power is off. If not, replace actuator. Check wiring for shorts.
Actuator makes buzzing noise but doesn't moveMotor fault; obstruction in valve.Replace actuator. Check valve for mechanical obstruction (requires draining system).
Actuator feels hot to touchNormal operation (slight warmth); internal fault (excessive heat).Slight warmth is normal. If excessively hot, disconnect power and replace actuator.

For persistent issues, it is recommended to contact a qualified heating engineer.

9. వారంటీ మరియు మద్దతు

For information regarding the warranty period and terms for your Drayton ZA5 Actuator, please refer to the documentation provided at the time of purchase or contact your retailer. Drayton products are typically covered by a manufacturer's warranty against defects in materials and workmanship.

For technical support or further assistance, please contact Drayton customer service or visit their official website. Ensure you have your product model number (ZA5) and part number (27650) ready when seeking support.

సంబంధిత పత్రాలు - ZA5

ముందుగాview Drayton TRV4 Thermostatic Radiator Valve Operating Instructions
Operating instructions and technical details for the Drayton TRV4 two-pipe thermostatic radiator valve. Covers installation, operation, range limiting, frost protection, and troubleshooting for optimal room temperature control.
ముందుగాview Drayton Installer Handbook: Comprehensive Guide to Heating Controls
The Drayton Installer Handbook provides detailed product information, specifications, and wiring diagrams for a wide range of Drayton heating controls, including thermostats, timeswitches, programmers, and valves, essential for professional installers.
ముందుగాview Drayton Automatic Balancing TRV Installation and Operating Instructions
Comprehensive guide to installing and operating Drayton's two-pipe thermostatic radiator valves with automatic balancing, ensuring efficient home heating and improved boiler efficiency.
ముందుగాview డ్రేటన్ ఆటోమేటిక్ బై-పాస్ వాల్వ్ ఇన్‌స్టాలేషన్ గైడ్
డ్రేటన్ ఆటోమేటిక్ బై-పాస్ వాల్వ్ (ABV) కోసం అధికారిక ఇన్‌స్టాలేషన్ గైడ్. సమర్థవంతమైన తాపన వ్యవస్థ ఆపరేషన్ కోసం భవన నిబంధనలు, సిస్టమ్ ఇంటిగ్రేషన్, సెట్టింగ్ విధానాలు, లక్షణాలు మరియు సాంకేతిక వివరణల గురించి తెలుసుకోండి.
ముందుగాview Wiser Smart Heating System Setup Guide | Drayton
Step-by-step guide to setting up your Drayton Wiser multi-zone smart heating system, including account creation, Hub connection, and feature overview.
ముందుగాview డ్రేటన్ RTS థర్మోస్టాట్ ఇన్‌స్టాలేషన్ గైడ్ మరియు సాంకేతిక లక్షణాలు
డ్రేటన్ RTS శ్రేణి థర్మోస్టాట్‌ల (RTS1, RTS2, RTS3, RTS4, RTS9, RTS10) కోసం సమగ్ర ఇన్‌స్టాలేషన్ సూచనలు, సాంకేతిక డేటా మరియు వైరింగ్ రేఖాచిత్రాలు. మోడల్ వివరాలు, స్థాన సలహా, ఫిక్సింగ్ దశలు మరియు అనుకూలత సమాచారాన్ని కలిగి ఉంటుంది.