FLIR MR77

FLIR MR77 Pinless Moisture Meter User Manual

Comprehensive instructions for operation and maintenance of your FLIR MR77 Moisture Meter.

1. పరిచయం

The FLIR MR77 Pinless Moisture Meter is a professional-grade instrument designed for accurate moisture and environmental measurements. This device combines pinless moisture detection with an external pin probe, relative humidity, and temperature sensing capabilities, making it a versatile tool for various applications.

This manual provides detailed instructions for the setup, operation, maintenance, and troubleshooting of your FLIR MR77 meter to ensure optimal performance and longevity.

2. అన్ప్యాకింగ్ మరియు కంటెంట్‌లు

Carefully unpack all items from the packaging. Verify that all components are present and undamaged. If any items are missing or damaged, contact your supplier immediately.

ప్యాకేజీ విషయాలు:

FLIR MR77 Pinless Moisture Meter

Figure 2.1: The FLIR MR77 Pinless Moisture Meter with its integrated sensor and display.

3. సెటప్ మరియు బ్యాటరీ ఇన్‌స్టాలేషన్

3.1 బ్యాటరీ ఇన్‌స్టాలేషన్

  1. మీటర్ వెనుక భాగంలో బ్యాటరీ కంపార్ట్‌మెంట్‌ను గుర్తించండి.
  2. బ్యాటరీ కంపార్ట్మెంట్ కవర్ తెరవండి.
  3. Insert the included 9V battery, observing correct polarity.
  4. బ్యాటరీ కంపార్ట్‌మెంట్ కవర్‌ను సురక్షితంగా మూసివేయండి.

3.2 Attaching Sensors

The MR77 comes with an integrated pinless sensor and ports for external sensors.

External Temperature and Relative Humidity Sensor

Figure 3.1: The external temperature and relative humidity sensor (MR01).

Pin Probe and Cable

Figure 3.2: The pin probe (MR02) for penetrating moisture measurements.

4. ఆపరేటింగ్ సూచనలు

4.1 పవర్ చేయడం ఆన్/ఆఫ్

నొక్కండి శక్తి button (usually located at the bottom of the device) to turn the meter on or off.

4.2 ప్రదర్శన ముగిసిందిview

Close-up of FLIR MR77 display showing moisture and temperature readings

Figure 4.1: Close-up of the MR77 display showing various readings.

The backlit LCD displays moisture readings, relative humidity, air temperature, dew point, and other relevant data. Icons indicate measurement mode, battery status, and other functions.

4.3 కొలత మోడ్‌లు

The FLIR MR77 offers multiple measurement capabilities:

Hand holding FLIR MR77 performing a pinless moisture measurement

Figure 4.2: Performing a pinless moisture measurement with the FLIR MR77.

Hand holding FLIR MR77 using the integrated IR thermometer with laser pointer

Figure 4.3: Using the integrated IR thermometer with laser targeting.

4.4 Material Group Selection

The MR77 allows selection of different material groups for more accurate moisture readings. Refer to the "Material Group Reference" table in the Specifications section for details on specific materials.

FLIR MR77 display showing material group and relative humidity

Figure 4.4: The display indicating the selected material group (M09) and Relative Humidity (RH).

4.5 డేటా నిల్వ మరియు రీకాల్

ఉపయోగించండి స్టోర్/రీకాల్ చేయండి button to save and retrieve measurement data. Consult the full user manual for detailed instructions on data logging and management.

4.6 Meter Link Smartphone App

The FLIR MR77 can connect to a smartphone app via Bluetooth for enhanced data monitoring, comparison, and reporting. Download the Meter Link app from your device's app store.

Screenshots of the FLIR Meter Link smartphone app showing data logging and comparison features

Figure 4.5: The Meter Link smartphone app interface for data monitoring and comparison.

5. నిర్వహణ

5.1 శుభ్రపరచడం

Wipe the meter's exterior with a damp cloth. Do not use abrasive cleaners or solvents. Keep the sensor areas clean and free of debris.

5.2 సెన్సార్ రీప్లేస్‌మెంట్

The temperature/relative humidity sensor (MR01) is field-replaceable. If readings become inaccurate or the sensor is damaged, replace it with an authorized FLIR replacement part. Refer to the full user manual for detailed replacement instructions.

5.3 నిల్వ

Store the FLIR MR77 in a cool, dry place when not in use. Remove the battery if storing for extended periods to prevent leakage.

6. ట్రబుల్షూటింగ్

సమస్యసాధ్యమైన కారణంపరిష్కారం
మీటర్ పవర్ ఆన్ అవ్వదు.డెడ్ లేదా తప్పుగా ఇన్‌స్టాల్ చేయబడిన బ్యాటరీ.Check battery polarity, replace battery.
Inaccurate moisture readings.Incorrect material group selected; sensor dirty or damaged; external interference.Verify material group; clean or replace sensor; move away from strong electromagnetic fields.
Inaccurate RH/Temperature readings.Sensor dirty or damaged.Clean or replace the MR01 sensor.
బ్లూటూత్ కనెక్టివిటీ సమస్యలు.Meter not in pairing mode; app issues; distance from device.Ensure meter Bluetooth is active; restart app/meter; reduce distance.

For further assistance, refer to the official FLIR MR77 User Manual (PDF) or contact FLIR customer support.

7. స్పెసిఫికేషన్లు

సాధారణ లక్షణాలు:

కొలత లక్షణాలు:

FLIR MR77 Specifications including moisture and environmental measurements

Figure 7.1: Detailed specifications for the FLIR MR77.

Material Group Reference:

Table of Material Group Reference for FLIR MR77

Figure 7.2: Reference table for selecting appropriate material groups for moisture measurements.

This table provides common names of timbers and other materials, along with their corresponding material group numbers (e.g., Group 1-8 for timbers, Group 9 for plywood, drywall, and oriented strand board, Group 10 for brick, cement screed, and concrete, Group 11 for cement mortar, anhydrite screed, lime mortar, and plaster). Groups 10 and 11 are not specified for accuracy and should be used for reference only.

8. వారంటీ సమాచారం

The FLIR MR77 Pinless Moisture Meter is covered by a పరిమిత జీవితకాల వారంటీ. For specific terms and conditions, including details on coverage and how to make a warranty claim, please refer to the official warranty documentation provided with your product or visit the FLIR webసైట్.

9. మద్దతు మరియు అదనపు వనరులు

For further information, technical support, or to access the complete user manual, please use the resources below:

సంబంధిత పత్రాలు - MR77

ముందుగాview FLIR MR77 User Manual: Pinless Moisture Psychrometer with IR Thermometer & Bluetooth
User manual for the FLIR MR77, a pinless moisture psychrometer featuring an infrared thermometer and METERLiNK Bluetooth connectivity. Learn about its features, operation, and specifications.
ముందుగాview FLIR MR77 యూజర్ మాన్యువల్: IR థర్మామీటర్‌తో పిన్‌లెస్ మాయిశ్చర్ సైక్రోమీటర్
FLIR MR77 కోసం యూజర్ మాన్యువల్, ఇది ఇన్‌ఫ్రారెడ్ థర్మామీటర్ మరియు బ్లూటూత్ METERLiNK కనెక్టివిటీని కలిగి ఉన్న పిన్‌లెస్ తేమ సైక్రోమీటర్. దాని లక్షణాలు, ఆపరేషన్ మరియు సాంకేతిక వివరణల గురించి తెలుసుకోండి.
ముందుగాview FLIR MR59 Ball Probe Moisture Meter Quick Start Guide
Quick start guide for the FLIR MR59 Ball Probe Moisture Meter with Bluetooth, covering setup, operation, meter description, function buttons, display indicators, and Bluetooth connectivity.
ముందుగాview FLIR MR176 Imaging Moisture Meter Plus with IGM User Manual
User manual for the FLIR MR176 Imaging Moisture Meter Plus, detailing its features, operation, maintenance, and specifications. Learn how to use its thermal imaging, pinless, and pin probe moisture measurement capabilities.
ముందుగాview FLIR E60 యాక్సెసరీ కిట్: థర్మల్ కెమెరా యాక్సెసరీల సమగ్ర జాబితా
FLIR E60 థర్మల్ ఇమేజింగ్ కెమెరా కోసం ఉపకరణాల వివరణాత్మక జాబితా, ఇందులో కేసులు, కేబుల్స్, విద్యుత్ సరఫరాలు, ఛార్జర్‌లు, బ్యాటరీలు, మెమరీ కార్డులు మరియు అడ్వాన్స్‌డ్ టెస్ట్ ఎక్విప్‌మెంట్ కార్పొరేషన్ నుండి డాక్యుమెంటేషన్ ఉన్నాయి.
ముందుగాview LTE డేటాషీట్‌తో FLIR iXX- సిరీస్ యాప్-ఎనేబుల్డ్ థర్మల్ కెమెరా
LTE తో FLIR iXX- సిరీస్ యాప్-ఎనేబుల్డ్ థర్మల్ కెమెరా కోసం వివరణాత్మక స్పెసిఫికేషన్లు మరియు ఫీచర్లు, IR రిజల్యూషన్, సెన్సిటివిటీ, FOV, అప్లికేషన్లు మరియు భౌతిక డేటాతో సహా.