1. పరిచయం
This manual provides essential information for the safe and effective installation, operation, and maintenance of the ABB B6-30-01-01 Compact 3-Pole Contactor. The B6-30-01-01 is a compact 3-pole contactor featuring one auxiliary contact and screw terminals, designed for reliable performance in applications where space is limited. It is suitable for controlling single or three-phase loads in residential, commercial, and industrial environments.
2. భద్రతా సమాచారం
హెచ్చరిక: Electrical shock hazard. Installation and maintenance should only be performed by qualified personnel. Disconnect all power before working on the contactor or connected equipment.
- ఎల్లప్పుడూ స్థానిక మరియు జాతీయ విద్యుత్ సంకేతాలు మరియు నిబంధనలను అనుసరించండి.
- అన్ని పరికరాల సరైన గ్రౌండింగ్ను నిర్ధారించుకోండి.
- వాల్యూమ్ అని ధృవీకరించండిtage and current ratings of the contactor match the application requirements.
- Do not operate the contactor if it is damaged.
3. ఉత్పత్తి ముగిసిందిview
The ABB B6-30-01-01 mini contactor is engineered for controlling various electrical loads. Key features include:
- కాంపాక్ట్ డిజైన్: Optimized for installations with limited space.
- 3-Pole Configuration: For switching three-phase loads.
- 1 Auxiliary Contact: One normally open (NO) auxiliary contact for control circuit applications.
- స్క్రూ టెర్మినల్స్: Secure and reliable electrical connections.
- Silent Coil: నిశ్శబ్ద ఆపరేషన్ను నిర్ధారిస్తుంది.
- Switch Position Indication: Visual indication of the contactor's state.
- మౌంటు ఎంపికలు: Integrated possibility for DIN rail or wall mounting.

మూర్తి 1: ABB B6-30-01-01 Compact Contactor. This image displays the grey and black casing of the contactor, clearly showing the screw terminals labeled 1L1, 3L2, 5L3 (inputs), 2T1, 4T2, 6T3 (outputs), A1, A2 (coil connections), and 13NO, 14NO (auxiliary contact). The ABB logo and a QR code are also visible on the unit.
4. స్పెసిఫికేషన్లు
| మోడల్ సంఖ్య | B6-30-01-01 (Manufacturer's Part Number: GJL1211001R0011) |
| బ్రాండ్ | ఎబిబి |
| పోల్స్ సంఖ్య | 3 |
| సహాయక పరిచయాలు | 1 సాధారణంగా తెరువు (NO) |
| టెర్మినల్ రకం | స్క్రూ టెర్మినల్స్ |
| Rated Operational Power (AC-3) | 4 kW వరకు |
| Rated Operational Current (AC-1) | 20 ఎ / 690 వి |
| కొలతలు (సుమారుగా) | 2.16 x 2.16 x 1.96 అంగుళాలు (54.86 x 54.86 x 49.78 మిమీ) |
| బరువు (సుమారు) | 4 ఔన్సులు (113 గ్రాములు) |
| మౌంటు | DIN Rail or Wall Mounting |
5. సంస్థాపన
Before beginning installation, ensure all power to the circuit is disconnected. The B6-30-01-01 contactor can be mounted on a standard DIN rail or directly to a panel using screws.
5.1 మౌంటు
- DIN రైలు మౌంటు: Align the contactor's integrated clips with the DIN rail and press firmly until it clicks into place.
- వాల్ మౌంటు: Use appropriate screws and anchors (not supplied) to secure the contactor through the designated mounting holes on the base. Ensure the mounting surface is stable and capable of supporting the contactor's weight and any connected wiring.
5.2. పర్యావరణ పరిగణనలు
Install the contactor in a clean, dry environment, free from excessive dust, moisture, corrosive gases, and extreme temperatures. Ensure adequate ventilation to prevent overheating.
6. వైరింగ్
Refer to the wiring diagram provided with your specific application and ensure all connections are secure. Use appropriate wire gauges for the expected current load.
6.1. Power Circuit Connections
- ఇన్పుట్ టెర్మినల్స్: Connect the incoming power lines to terminals 1L1, 3L2, మరియు 5L3.
- అవుట్పుట్ టెర్మినల్స్: Connect the load to terminals 2T1, 4T2, మరియు 6T3.
6.2. Control Circuit Connections
- కాయిల్ టెర్మినల్స్: నియంత్రణ వాల్యూమ్ను కనెక్ట్ చేయండిtage to terminals A1 మరియు A2. Ensure the control voltage matches the coil voltage rating of the contactor.
- సహాయక సంప్రదింపు: The normally open (NO) auxiliary contact is connected to terminals 13NO మరియు 14NO. This contact closes when the main coil is energized.
Tighten all screw terminals to the manufacturer's specified torque to ensure reliable electrical contact and prevent loose connections.
7. ఆపరేషన్
The ABB B6-30-01-01 contactor operates by energizing its coil. When the appropriate control voltage is applied to terminals A1 and A2, the coil creates a magnetic field, pulling the main contacts closed and connecting the power circuit from 1L1/3L2/5L3 to 2T1/4T2/6T3. Simultaneously, the auxiliary contact (13NO-14NO) will close.
- కాయిల్ను శక్తివంతం చేయడం: Applying the rated control voltage to A1 and A2 will close the main and auxiliary contacts.
- కాయిల్ను శక్తివంతం చేయడం: నియంత్రణ వాల్యూమ్ను తీసివేయడంtage from A1 and A2 will cause the coil to de-energize, opening the main and auxiliary contacts.
- Switch Position Indication: A visual indicator on the contactor provides feedback on the current state of the main contacts (e.g., '0' for open, 'I' for closed, or a similar marking).
8. నిర్వహణ
Regular maintenance helps ensure the longevity and reliable operation of the contactor. Always disconnect power before performing any maintenance.
- దృశ్య తనిఖీ: Periodically inspect the contactor for any signs of damage, discoloration, loose connections, or excessive dust accumulation.
- శుభ్రపరచడం: Use a dry, soft cloth or compressed air to remove dust and debris from the contactor's exterior. Do not use solvents or abrasive cleaners.
- టెర్మినల్ బిగుతు: Check and re-tighten all screw terminals as necessary to prevent overheating due to loose connections.
- కాంటాక్ట్ వేర్: While internal contacts are generally not user-serviceable, excessive arcing or contact welding may indicate a need for replacement.
9. ట్రబుల్షూటింగ్
కాంటాక్టర్ ఆశించిన విధంగా పనిచేయకపోతే, ఈ క్రింది సాధారణ సమస్యలను పరిగణించండి:
- Contactor Does Not Energize:
- Check if the control voltage is present at terminals A1 and A2.
- నియంత్రణ వాల్యూమ్ను ధృవీకరించండిtage matches the coil's rated voltage.
- Inspect control circuit wiring for loose connections or breaks.
- Contactor Energizes But Load Does Not Receive Power:
- Ensure main power is supplied to 1L1, 3L2, 5L3.
- Check connections to the load at 2T1, 4T2, 6T3.
- Verify the contactor's switch position indicator shows 'closed'.
- వేడెక్కడం:
- వదులుగా ఉన్న టెర్మినల్ కనెక్షన్ల కోసం తనిఖీ చేయండి.
- Ensure the load current does not exceed the contactor's ratings.
- Verify adequate ventilation around the contactor.
If issues persist after troubleshooting, contact qualified electrical personnel or ABB technical support.
10. వారంటీ సమాచారం
Specific warranty terms and conditions for the ABB B6-30-01-01 contactor are provided by ABB at the time of purchase. Please refer to the documentation included with your product or visit the official ABB webవివరణాత్మక వారంటీ సమాచారం కోసం సైట్. వారంటీ క్లెయిమ్ల కోసం మీ కొనుగోలు రుజువును ఉంచండి.
11. సాంకేతిక మద్దతు
For technical assistance, product inquiries, or service, please contact ABB customer support. Contact information can typically be found on the official ABB website or through your local ABB distributor.
ABB అధికారి Webసైట్: www.abb.com