1. పరిచయం
This manual provides comprehensive instructions for the installation, operation, and maintenance of your CHACON Motion Detector, model 34310. This device is designed to automatically switch lighting on and off based on detected movement, contributing to energy savings and convenience in indoor environments. Please read this manual thoroughly before installation and use to ensure proper function and safety.
2. భద్రతా సూచనలు
పరికరానికి గాయం లేదా నష్టం జరగకుండా నిరోధించడానికి ఎల్లప్పుడూ క్రింది భద్రతా మార్గదర్శకాలను పాటించండి:
- స్థానిక ఎలక్ట్రికల్ కోడ్లు మరియు నిబంధనలకు అనుగుణంగా అర్హత కలిగిన ఎలక్ట్రీషియన్ లేదా సమర్థ వ్యక్తి ద్వారా ఇన్స్టాలేషన్ నిర్వహించబడాలి.
- Disconnect the main power supply before commencing any installation, wiring, or maintenance work.
- Do not exceed the maximum load capacity of 500 watts for incandescent lamps.
- Ensure the device is connected to a 230V ~ 50Hz power supply.
- Do not attempt to disassemble or modify the device. There are no user-serviceable parts inside.
- పరికరాన్ని నీరు, తేమ మరియు తీవ్రమైన ఉష్ణోగ్రతల నుండి దూరంగా ఉంచండి.
3. ఉత్పత్తి ముగిసిందిview
The CHACON 34310 Motion Detector integrates a Passive Infrared (PIR) sensor to detect movement within its coverage area. It features a simple interface for mode selection.

This image displays the front panel of the CHACON 34310 Motion Detector. It features a white rectangular housing with a translucent, ribbed PIR sensor window at the top. Below the sensor, there is a small white switch with 'ON', 'AUTO', and 'OFF' labels, indicating the operating modes. The overall design is simple and functional, suitable for indoor wall mounting.
ముఖ్య భాగాలు:
- PIR Sensor Window: Detects infrared radiation emitted by moving objects.
- మోడ్ సెలెక్టర్ స్విచ్: Allows selection between ON, AUTO, and OFF modes.
- Adjustment Dials (Internal/Concealed): Used to set time delay and light sensitivity. These are typically accessed during installation or setup.
4. సెటప్ మరియు ఇన్స్టాలేషన్
సరైన పనితీరు కోసం జాగ్రత్తగా ప్రణాళిక మరియు అమలు చేయడం చాలా అవసరం.
4.1 ప్రీ-ఇన్స్టాలేషన్ పరిగణనలు
- విద్యుత్ సరఫరా: Ensure a stable 230V ~ 50Hz power source is available at the installation location.
- లోడ్ అనుకూలత: The detector supports a maximum load of 500 watts for incandescent lamps. Verify your lighting fixture's wattage.
- మౌంటు రకం: Designed for indoor mounting.
4.2 ప్లేస్మెంట్ మార్గదర్శకాలు
Proper placement is critical for effective motion detection and to avoid false triggers.
- కవరేజ్ ప్రాంతం: The detector has a 120° detection angle and a maximum range of 8 meters. Position it to cover the desired area effectively.
- అడ్డంకులను నివారించండి: Ensure the sensor has a clear line of sight to the area it monitors. Walls, furniture, or large objects can block detection.
- Minimize False Triggers:
- Do not install near heat sources such as heating vents, radiators, or direct sunlight, as these can cause false activations.
- Avoid aiming the sensor directly at windows where moving vehicles or pedestrians outside could trigger it.
- Keep away from areas with strong air currents (e.g., near fans or air conditioning units) that might cause temperature fluctuations.
4.3 వైరింగ్ సూచనలు
WARNING: Ensure power is disconnected at the main circuit breaker before proceeding with wiring.
- Carefully open the detector housing to access the wiring terminals.
- Connect the Live (L) wire from the power supply to the Live input terminal on the detector.
- Connect the Neutral (N) wire from the power supply to the Neutral input terminal on the detector.
- Connect the Switched Live (L') output terminal of the detector to the Live input of your lighting fixture.
- Connect the Neutral wire from the lighting fixture to the Neutral wire of the main power supply (or to the Neutral terminal on the detector if provided for load).
- Secure all connections firmly and ensure no bare wires are exposed.
- Close the detector housing and mount it securely in the chosen location.
5. ఆపరేటింగ్ సూచనలు
Once installed, the CHACON 34310 Motion Detector can be configured and operated using its mode selector switch and internal adjustment dials.
5.1 Mode Selector Switch
The front-facing switch allows you to select the operating mode:
- పై: The connected light will remain continuously on, regardless of motion detection or ambient light levels.
- దానంతట అదే: The detector will operate in automatic mode. The light will turn on when motion is detected and ambient light conditions meet the set sensitivity, and will turn off after the set time delay.
- ఆఫ్: The connected light will remain continuously off, regardless of motion detection.
5.2 Adjustment Dials (Time and Light Sensitivity)
These dials are typically located behind the front cover or on the side of the unit and are used to fine-tune the detector's behavior. Adjust them using a small screwdriver if necessary.
- Time Delay (Durable): This dial controls how long the light remains on after the last detected motion. It is adjustable from approximately 10 seconds to 4 minutes. Turn clockwise to increase the duration, counter-clockwise to decrease.
- Light Sensitivity (Candle Power Command): This dial determines the ambient light level at which the detector will become active. It can be adjusted from full darkness (light will activate even in bright conditions) to daylight (light will only activate in low light conditions). Turn clockwise for higher sensitivity (activates in brighter conditions), counter-clockwise for lower sensitivity (activates only in darker conditions).
6. నిర్వహణ
The CHACON 34310 Motion Detector requires minimal maintenance.
- శుభ్రపరచడం: Periodically wipe the sensor window and housing with a soft, dry cloth to remove dust and dirt. Do not use abrasive cleaners, solvents, or excessive moisture.
- తనిఖీ: Occasionally check for any visible damage to the housing or wiring. If damage is found, disconnect power and consult a qualified electrician.
- వినియోగదారు-సేవ చేయదగిన భాగాలు లేవు: Do not attempt to open the unit for internal cleaning or repair.
7. ట్రబుల్షూటింగ్
If you experience issues with your motion detector, refer to the following common problems and solutions:
| సమస్య | సాధ్యమైన కారణం | పరిష్కారం |
|---|---|---|
| కదలిక గుర్తించబడినప్పుడు కాంతి వెలగదు. |
|
|
| Light stays on continuously or turns on randomly (false triggers). |
|
|
| లైట్ చాలా త్వరగా లేదా చాలా నెమ్మదిగా ఆరిపోతుంది. | సమయ ఆలస్యం సెట్టింగ్ తప్పు. | Adjust the time delay dial to the desired duration. |
| Light flickers when connected to the detector. |
|
|
If these troubleshooting steps do not resolve the issue, contact a qualified electrician or the product retailer for further assistance.
8. స్పెసిఫికేషన్లు
| ఫీచర్ | స్పెసిఫికేషన్ |
|---|---|
| బ్రాండ్ | చాకోన్ |
| మోడల్ సంఖ్య | 34310 |
| శక్తి మూలం | Mains Powered (230V ~ 50Hz) |
| గరిష్ట లోడ్ | 500 watts (incandescent lamp) |
| డిటెక్షన్ యాంగిల్ | 120 డిగ్రీలు |
| గరిష్ట పరిధి | 8 మీటర్లు |
| సమయం ఆలస్యం సర్దుబాటు | Approx. 10 seconds to 4 minutes |
| Light Sensitivity Adjustment | Stepless from daylight to full darkness |
| మౌంటు రకం | Indoor mounting |
| మెటీరియల్ | PVC |
| రంగు | తెలుపు |
| ఉత్పత్తి కొలతలు | 12 x 6 x 16 సెం.మీ |
| వస్తువు బరువు | 0.14 కిలోలు |
| ఎగువ ఉష్ణోగ్రత రేటింగ్ | 75 డిగ్రీల సెల్సియస్ |
9. వారంటీ మరియు మద్దతు