SIMPLEX 4009-9201

SIMPLEX 4009-9201 NAC Extender Instruction Manual

మోడల్: 4009-9201

1. పరిచయం

This manual provides essential information for the proper installation, operation, and maintenance of the SIMPLEX 4009-9201 Notification Appliance Circuit (NAC) Extender. This device is designed to expand the capacity of existing fire alarm systems by providing additional supervised and synchronized NACs.

It is imperative that all personnel involved in the installation, testing, and maintenance of this equipment read and understand the contents of this manual completely before proceeding. Adherence to all local and national electrical codes, as well as fire safety regulations, is mandatory.

ముందు view of the SIMPLEX 4009-9201 NAC Extender enclosure.

మూర్తి 1: ముందు view of the SIMPLEX 4009-9201 NAC Extender enclosure. The unit is a rectangular metal box, light gray in color, with ventilation slots at the top and bottom. A black label across the center reads "4009 IDNet NAC EXTENDER" with the Simplex logo.

2. భద్రతా సమాచారం

హెచ్చరిక: Installation and servicing of this equipment must be performed by qualified personnel only. Disconnect all power before servicing.

  • Always disconnect AC power and battery power before installing, servicing, or removing the unit.
  • Ensure proper grounding of the unit as per local electrical codes.
  • యూనిట్‌ను తేమ లేదా తీవ్రమైన ఉష్ణోగ్రతలకు గురిచేయవద్దు.
  • తయారీదారు ఆమోదించిన భర్తీ భాగాలను మాత్రమే ఉపయోగించండి.
  • పవర్ వర్తించే ముందు అన్ని వైరింగ్ కనెక్షన్లు సురక్షితంగా మరియు సరిగ్గా ఉన్నాయని ధృవీకరించండి.

3. ఉత్పత్తి లక్షణాలు

The SIMPLEX 4009-9201 NAC Extender is designed to provide reliable and expandable notification appliance circuit capabilities for fire alarm systems. Key features include:

  • Expansion of Notification Appliance Circuits (NACs).
  • Supervised circuits for integrity monitoring.
  • Synchronization capabilities for connected notification appliances.
  • Robust enclosure for industrial and commercial environments.

4. సెటప్ మరియు ఇన్‌స్టాలేషన్

Installation of the SIMPLEX 4009-9201 NAC Extender requires careful attention to wiring and system integration. It is recommended that installation be performed by a certified fire alarm technician.

4.1 అన్‌ప్యాకింగ్ మరియు తనిఖీ

Upon receiving the unit, carefully inspect the packaging for any signs of damage. Open the package and verify that all components are present and undamaged. Report any discrepancies to your supplier immediately.

4.2 మౌంటు

Mount the NAC Extender securely to a wall or suitable surface in a dry, protected area, away from direct sunlight and heat sources. Ensure adequate ventilation around the unit.

4.3 వైరింగ్ కనెక్షన్లు

Refer to the internal wiring diagram and system schematics for precise connection details. All wiring must comply with NFPA 70 (National Electrical Code) and NFPA 72 (National Fire Alarm and Signaling Code), as well as all local authority having jurisdiction (AHJ) requirements.

అంతర్గత view of the SIMPLEX 4009-9201 NAC Extender with wiring diagram.

చిత్రం 2: అంతర్గత view of the SIMPLEX 4009-9201 NAC Extender. The enclosure door is open, revealing the main circuit board, a large transformer, and various wiring connections. A detailed wiring and configuration diagram is affixed to the inside of the door.

Close-up of the internal components of the SIMPLEX 4009-9201 NAC Extender.

మూర్తి 3: క్లోజ్-అప్ view of the internal components of the SIMPLEX 4009-9201 NAC Extender. This image highlights the main circuit board with various electronic components, capacitors, and relays, alongside the large toroidal transformer and associated wiring.

  • Connect the AC power input to a dedicated, unswitched circuit as specified in the technical specifications.
  • Connect the battery backup terminals to appropriate standby batteries (if applicable) to ensure continuous operation during power outages.
  • Connect the NAC outputs to the notification appliances (horns, strobes, speakers) ensuring proper polarity and supervision.
  • Connect the input from the fire alarm control panel (FACP) to the designated terminals.

4.4 Power-Up and Initial Test

After all wiring is complete and verified, apply AC power to the unit. Observe any status indicators for normal operation. Perform initial system tests as per the FACP manufacturer's instructions and relevant fire codes to ensure all connected NACs and appliances function correctly.

5. ఆపరేటింగ్ సూచనలు

The SIMPLEX 4009-9201 NAC Extender operates in conjunction with a compatible fire alarm control panel (FACP). Its primary function is to receive signals from the FACP and activate connected notification appliances.

5.1 సాధారణ ఆపరేషన్

Under normal conditions, the NAC Extender will be in a standby state, supervising its connected circuits. Status indicators (if present) should show a normal, non-alarm condition.

5.2 అలారం యాక్టివేషన్

Upon receiving an alarm signal from the FACP, the NAC Extender will activate its connected notification appliances according to the programmed sequence (e.g., continuous, temporal 3, synchronized). The unit will continue to power the appliances until the alarm condition is cleared by the FACP.

5.3 Trouble Conditions

The NAC Extender continuously monitors its circuits for trouble conditions such as open circuits, short circuits, or ground faults. If a trouble condition is detected, the unit will typically send a signal back to the FACP, and a local trouble indicator may illuminate.

6. నిర్వహణ

Regular maintenance is crucial for the reliable operation of the SIMPLEX 4009-9201 NAC Extender and the overall fire alarm system.

  • వార్షిక తనిఖీ: Have a qualified technician inspect the unit annually as part of the overall fire alarm system inspection.
  • బ్యాటరీ తనిఖీ: If equipped with battery backup, check battery terminals for corrosion and test battery voltage and capacity regularly as per NFPA 72 guidelines. Replace batteries as needed.
  • శుభ్రపరచడం: Keep the exterior of the unit clean and free of dust. Do not use abrasive cleaners or solvents.
  • వైరింగ్ సమగ్రత: Periodically check all wiring connections for tightness and signs of wear or damage.

7. ట్రబుల్షూటింగ్

This section provides basic troubleshooting steps for common issues. For complex problems, contact a qualified fire alarm technician.

సమస్యసాధ్యమైన కారణంపరిష్కారం
NAC Extender not powering on.No AC power; Blown fuse; Disconnected battery.Check AC power source; Inspect and replace fuse if necessary (ensure power is off); Verify battery connections.
Trouble indicator illuminated.Open circuit on NAC; Short circuit on NAC; Ground fault; Low battery.Inspect NAC wiring for breaks or shorts; Check for ground faults; Test and replace battery if low.
Notification appliances not activating.No alarm signal from FACP; Wiring error on NAC output; Faulty appliance.Verify FACP is in alarm; Check NAC output wiring; Test individual appliances.

8. స్పెసిఫికేషన్లు

The following specifications apply to the SIMPLEX 4009-9201 NAC Extender:

స్పెసిఫికేషన్విలువ
మోడల్ సంఖ్య4009-9201
తయారీదారుసింప్లెక్స్
UPC643485653868
గరిష్ట ఇన్పుట్ వాల్యూమ్tage120 వోల్ట్‌లు (AC)
కనిష్ట ఇన్‌పుట్ వాల్యూమ్tage100 వోల్ట్‌లు (AC)
అంశం కొలతలు (L x W x H)17 x 20 x 8 అంగుళాలు
వస్తువు బరువు22.9 పౌండ్లు
శీతలీకరణ పద్ధతిగాలి
ఫారమ్ ఫ్యాక్టర్ATX
కనెక్టర్ రకంATX
Shipping label for the SIMPLEX 4009-9201 NAC Extender.

Figure 4: Shipping label for the SIMPLEX 4009-9201 NAC Extender. The label displays the PID: 4009-9201, Description: NAC EXTENDER 120VAC, IDNET, Part No. 0636867, and Serial Number information.

9. వారంటీ మరియు మద్దతు

The SIMPLEX 4009-9201 NAC Extender is covered by the manufacturer's standard warranty. For specific warranty terms and conditions, please refer to the documentation provided with your purchase or contact SIMPLEX directly.

For technical support, service, or to report issues, please contact your authorized SIMPLEX distributor or the manufacturer's customer service department. Always provide the model number (4009-9201) and serial number of your unit when seeking support.

సంబంధిత పత్రాలు - 4009-9201

ముందుగాview Simplex 4009 IDNet NAC Extender Installation and Operation Guide
Comprehensive guide for installing and configuring the Simplex 4009 IDNet Notification Appliance Circuit (NAC) Extender. Covers hardware components, system configuration, wiring, and operational modes for fire alarm systems.
ముందుగాview Simplex 4090-9007 IDNet Signal IAM: Addressable Module for Fire Alarm Systems
Detailed technical specifications and features for the Simplex 4090-9007 IDNet Signal Individual Addressable Module (IAM), designed for enhanced selective signaling and audio control in Simplex 4100ES, 4010ES, 4100U, and 4008 Series fire alarm control panels. Includes wiring, operation, and mounting information.
ముందుగాview Simplex 4008/4006-9801 Expansion Power Supply (EPS) Installation Guide
Installation instructions for the Simplex 4008/4006-9801 Expansion Power Supply (EPS), detailing mounting, panel interconnections, NAC wiring, auxiliary power, and NAC ratings for fire alarm systems.
ముందుగాview సింప్లెక్స్ 4010ES: సిస్టమ్స్ డి కమాండే డి'ఎక్స్‌టింక్షన్ ఆటోమేటిక్ పోర్ గిక్లర్స్
గైడ్ టెక్నిక్ సింప్లెక్స్ 4010ES డిటైలెంట్ లెస్ మాడ్యూల్స్ డి కమాండే పోర్ లెస్ సిస్టమ్స్ డి'ఎక్స్‌టింక్షన్ ఆటోమేటిక్ పార్ గిక్లెర్స్, కౌవ్రాంట్ లెస్ మోడ్‌లు డెల్యూజ్ మరియు ప్రెవెంటిఫ్, అవెక్ స్పెసిఫికేషన్స్, హోమోలోగేషన్స్ మరియు స్కీమాస్ డి సిబ్లేజ్.
ముందుగాview Simplex IDNet Signal IAM Installation Instructions
Detailed installation instructions for the Simplex 4090-9007 IDNet Addressable Signal Individual Adapter Module (Signal IAM), covering address setting, wiring configurations for Class A and Class B Notification Appliance Circuits (NACs), and mounting procedures. This guide provides essential information for integrating the Signal IAM with fire alarm control panels and notification appliances.
ముందుగాview సింప్లెక్స్ 4010ES ఫైర్ అలారం సిస్టమ్ ఇన్‌స్టాలేషన్ గైడ్
ఈ ఇన్‌స్టాలేషన్ గైడ్ సింప్లెక్స్ 4010ES ఫైర్ అలారం సిస్టమ్ కోసం సమగ్ర సూచనలను అందిస్తుంది, ఇది స్వతంత్ర మరియు నెట్‌వర్క్డ్ కాన్ఫిగరేషన్‌లు, హార్డ్‌వేర్ భాగాలు, వైరింగ్ మరియు సిస్టమ్ చెక్‌అవుట్ విధానాలను కవర్ చేస్తుంది.