పరిచయం
This manual provides comprehensive instructions for the Anderic Replacement FAN-9T Thermostatic Remote Control, designed specifically for Hampton Bay ceiling fans.

చిత్రం: ముందు భాగం view of the Anderic FAN-9T remote control, showing the display and various control buttons.
అనుకూలత
The Anderic FAN-9T remote control is compatible with Hampton Bay ceiling fans. To ensure compatibility, verify that your original remote control has "FAN-9T" printed on its back. This remote features FCC ID: L3HFAN9T and PN: FAN9TR.
ముఖ్యమైన గమనిక: This remote control provides on/off functionality for lights and does not support dimming. If your original remote for a Windward II 54-inch Ceiling Fan has a model number starting with "CHQ" (located on the back), you may require the RR7096TR model with a yellow light button, even if your original has a green light button.
కీ ఫీచర్లు
- రివర్స్ ఆపరేషన్: Easily switch the ceiling fan's rotation direction for optimal airflow in different seasons.
- Thermostatic Function: Set a desired temperature, and the remote will automatically adjust fan speed to maintain a comfortable environment.
- Lights On/Off Control: Conveniently turn your ceiling fan's lights on or off with a dedicated button.
- ఉష్ణోగ్రత మార్పిడి: Switch between Celsius and Fahrenheit temperature displays by holding the TEMP UP and TEMP DOWN buttons simultaneously for 3 seconds.
- Wall Mount Holder: Includes a wall mount holder for convenient storage and accessibility of the remote.
సెటప్ సూచనలు
Before using your new Anderic FAN-9T remote control, follow these steps to install batteries and set the correct code for your ceiling fan receiver.
1. బ్యాటరీ ఇన్స్టాలేషన్
- Remove the battery cover located on the back of the remote control. Press firmly below the arrow and slide the cover off.
- సరైన ధ్రువణతను (+/-) నిర్ధారించుకుని, నాలుగు (4) AAA బ్యాటరీలను చొప్పించండి.
- బ్యాటరీ కవర్ను భర్తీ చేయండి.

చిత్రం: వెనుక view of the remote control with the battery cover removed, revealing the battery slots and DIP switches.
2. Setting the Code (DIP Switches)
The remote control and your ceiling fan receiver must be set to the same code for proper communication. This unit has 16 different code combinations. Ensure your fan is operated in "HIGH SPEED" and the light is in "ON" condition at the switch knob before proceeding.
- రిమోట్లో కోడ్ని సెట్ చేస్తోంది:
- With the battery cover removed, locate the DIP switches inside the battery compartment.
- Slide the code switches to your desired up or down position. (Factory setting is all up. Do not use this position unless it matches your receiver.) Use a small screwdriver or a ballpoint pen to firmly slide the switches.
- Replace the battery cover on the transmitter (remote).
- రిసీవర్లో కోడ్ను సెట్ చేస్తోంది:
- Locate the receiver unit within your ceiling fan assembly.
- Slide the code switches on the receiver to the exact same positions (up/down) as you set on your remote control.

Image: Diagram illustrating how to set the code switches on both the remote control (transmitter) and the ceiling fan receiver.
Once both the remote and receiver codes are matched, your remote control should be ready for operation.
ఆపరేటింగ్ సూచనలు
Familiarize yourself with the buttons on your Anderic FAN-9T remote control to operate your ceiling fan effectively.

చిత్రం: కోణీయ view of the Anderic FAN-9T remote control, highlighting the button layout.
- ఫ్యాన్ స్పీడ్ కంట్రోల్: Use the "MANUAL LOW" and "HIGH" indicators on the display to adjust fan speed. The remote automatically adjusts fan speed in thermostatic mode.
- FAN AUTO Button: Activates or deactivates the automatic fan speed adjustment based on the set temperature.
- FOR/REV Button: Press this button to change the direction of the fan blades (forward for cooling, reverse for heat circulation).
- లైట్ బటన్: Press to turn the ceiling fan lights ON or OFF. (Note: This remote does not support dimming.)
- TIMER బటన్: Activates the fan timer function. Refer to your fan's specific instructions for timer settings.
- LIGHT DELAY Button: Activates the light delay function. Refer to your fan's specific instructions for light delay settings.
- TEMP UP / TEMP DOWN Buttons: Adjust the desired temperature setting for the thermostatic function.
- Temperature Unit Conversion (C/F): To switch between Celsius and Fahrenheit, hold down the TEMP UP and TEMP DOWN buttons simultaneously for 3 seconds.
నిర్వహణ
- శుభ్రపరచడం: రిమోట్ కంట్రోల్ను మృదువైన, పొడి గుడ్డతో తుడవండి. రాపిడి క్లీనర్లు లేదా ద్రావకాలను ఉపయోగించవద్దు.
- బ్యాటరీ భర్తీ: Replace batteries when the remote's performance degrades or the display becomes dim. Always use new AAA batteries and dispose of old batteries responsibly.
- నిల్వ: When not in use for extended periods, remove batteries to prevent leakage. Store the remote in a cool, dry place.

Image: The Anderic FAN-9T remote control securely placed in its included wall mount holder.
ట్రబుల్షూటింగ్
| సమస్య | సాధ్యమైన కారణం | పరిష్కారం |
|---|---|---|
| Remote not responding / Fan not working. |
|
|
| లైట్లు పనిచేయడం లేదు. |
|
|
| ఉష్ణోగ్రత ప్రదర్శన తప్పు. | Incorrect temperature unit setting. | Hold TEMP UP and TEMP DOWN buttons simultaneously for 3 seconds to switch between Celsius and Fahrenheit. |
స్పెసిఫికేషన్లు
| గుణం | వివరాలు |
|---|---|
| ఉత్పత్తి కొలతలు | 3 x 1 x 6 అంగుళాలు |
| వస్తువు బరువు | 4.8 ఔన్సులు |
| మోడల్ సంఖ్య | FAN9T |
| బ్యాటరీలు అవసరం | 4 AAA బ్యాటరీలు |
| రంగు | తెలుపు |
| అనుకూల పరికరాలు | Hampటన్ బే సీలింగ్ ఫ్యాన్స్ |
| FCC ID | L3HFAN9T |
| PN | FAN9TR |
మద్దతు సమాచారం
Anderic is committed to providing high-quality replacement remote controls and accessories. For further assistance or inquiries, please refer to the official Anderic webసైట్ లేదా వారి కస్టమర్ సపోర్ట్ని సంప్రదించండి.
Anderic is a company based in NC, USA, dedicated to ensuring the highest quality standards for their products.





