Paradox 307-USB-modul

పారడాక్స్ 307-USB మాడ్యూల్ యూజర్ మాన్యువల్

Your comprehensive guide to the Paradox 307-USB Module for direct PC-to-panel connection.

1. పరిచయం

The Paradox 307-USB Module is an essential interface designed for direct communication between your personal computer (PC) and Paradox security control panels. This module simplifies the process of programming, configuring, and managing your security system by providing a reliable USB connection.

It features a USB port and a serial port (DB-9), along with three LED indicators for PC, Central, and RX/TX status, offering clear visual feedback on the communication link.

Paradox 307-USB Module, a white rectangular device with a USB port, a DB-9 serial port, and a cable with a white connector.

Figure 1: The Paradox 307-USB Module, showing its compact design, USB and serial (DB-9) ports, and the integrated connection cable. This module facilitates direct data exchange between a computer and a Paradox security system panel.

2. సెటప్ మరియు ఇన్‌స్టాలేషన్

Follow these steps to set up your Paradox 307-USB Module for the first time:

  1. PCకి కనెక్ట్ చేయండి: Plug the USB end of the 307-USB Module into an available USB port on your computer. The module is generally plug-and-play and often does not require specific driver installation, especially on modern operating systems like Windows 10.
  2. Connect to Control Panel: Connect the serial (DB-9) port of the 307-USB Module to the corresponding serial communication port on your Paradox security control panel. Ensure a secure connection.
  3. సాఫ్ట్‌వేర్ ఇన్‌స్టాలేషన్: Download and install the necessary Paradox programming software (e.g., WinLoad, BabyWare) from the official Paradox website. This software is crucial for configuring and managing your security system through the module.
  4. కనెక్షన్‌ని ధృవీకరించండి: Once connected, observe the three LED indicators on the module:
    • PC LED: Indicates connection and communication with the PC.
    • సెంట్రల్ LED: Indicates connection and communication with the control panel.
    • RX/TX LED: Flashes during data transmission (Receive/Transmit) between the PC and the control panel.
  5. Initial Communication: Open the Paradox programming software on your PC. Configure the software to use the correct communication port (usually a virtual COM port assigned to the USB module). Attempt to establish communication with the control panel.

The module supports communication speeds of up to 38.4 K with Digiplex EVO central units and 9.6 K with Magellan and Spectra SP central units.

3. ఆపరేటింగ్ సూచనలు

The Paradox 307-USB Module acts as a bridge, facilitating data exchange. Its operation is primarily managed through the Paradox programming software on your PC.

4. నిర్వహణ

The Paradox 307-USB Module is designed for low maintenance. To ensure its longevity and reliable performance, consider the following:

5. ట్రబుల్షూటింగ్

If you encounter issues with your Paradox 307-USB Module, refer to the following common troubleshooting steps:

సమస్యసాధ్యమైన కారణంపరిష్కారం
PC LED is offModule not connected to PC, or PC USB port issue.Ensure the USB cable is securely plugged into the PC. Try a different USB port. Restart the PC.
Central LED is offModule not connected to control panel, or control panel is off.Verify the DB-9 serial connection to the control panel. Ensure the control panel is powered on.
RX/TX LEDs not flashing during communication attemptNo data transfer, incorrect software settings, or communication error.
  • Check the communication port settings in your Paradox software (e.g., COM port number).
  • Ensure the correct control panel model is selected in the software.
  • Verify the control panel's communication settings.
  • Restart the Paradox software and try again.
Software cannot detect module/panelDriver issue (rare), incorrect COM port, or software conflict.
  • Check Device Manager on your PC to confirm the module is recognized and assigned a COM port.
  • Ensure no other software is using the same COM port.
  • Reinstall the Paradox programming software.

If problems persist, consult the Paradox programming software's help documentation or contact Paradox technical support.

6. స్పెసిఫికేషన్లు

Key technical specifications for the Paradox 307-USB Module:

7. వారంటీ సమాచారం

Specific warranty terms for the Paradox 307-USB Module are provided by the manufacturer, Paradox, and may vary based on region and point of purchase. Please retain your proof of purchase for warranty claims.

For detailed warranty information, including coverage period and conditions, please refer to the documentation included with your product or visit the official Paradox website. Any repairs or modifications performed by unauthorized personnel will void the warranty.

8. Technical Support and Contact

For technical assistance, troubleshooting beyond this manual, or inquiries regarding your Paradox 307-USB Module, please contact Paradox technical support.

When contacting support, please have your product model (307-USB Module) and any relevant error messages or observations ready to facilitate a quicker resolution.

సంబంధిత పత్రాలు - 307-USB-modul

ముందుగాview Οδηγός Προγραμματισμού Σειρών Paradox Magellan & Spectra SP
Ολοκληρωμένος οδηγός προγραμματισμού για τις σειρές συστημάτων συναγερμού Paradox Magellan και Spectra SP, καλύπτοντας εγκατάσταση, διαμόρφωση και προηγμένες λειτουργίες.
ముందుగాview Paradox PGM4 Expansion Module V3.0 Installation and Programming Guide
Comprehensive guide for installing and programming the Paradox PGM4 4-output expansion module (V3.0) with compatible control panels like Digiplex, EVO, MG/SP, Esprit E55, and Spectra. Covers wiring, programming methods via keypad and WinLoad software, firmware upgrades, and technical specifications.
ముందుగాview Paradox RPT1+ Wireless Repeater Module Installation Manual
Installation manual for the Paradox RPT1+ Wireless Repeater Module, detailing its features, installation steps, and programming information for enhancing Magellan and Spectra SP alarm systems.
ముందుగాview Digiplex EVO192 Programming Guide: High Security & Access System
Comprehensive programming guide for the Paradox Digiplex EVO192 High Security and Access System (V7.11), detailing configuration, zone programming, and system settings.
ముందుగాview పారడాక్స్ మాగెల్లాన్ మరియు స్పెక్ట్రా SP అలారం సిస్టమ్ యూజర్ గైడ్
పారడాక్స్ మాగెల్లాన్ (MG5000, MG5050) మరియు స్పెక్ట్రా SP (SP65, SP4000, SP5500, SP6000, SP7000) అలారం సిస్టమ్‌ల కోసం సమగ్ర వినియోగదారు గైడ్, ఆపరేషన్, ఫీచర్లు మరియు ప్రోగ్రామింగ్‌ను కవర్ చేస్తుంది.
ముందుగాview పారడాక్స్ మాగెల్లాన్ & స్పెక్ట్రా SP ఇన్‌స్టాలేషన్ గైడ్
MG5075, MG5050, SP4000, మరియు SP7000 వంటి మోడళ్లను కవర్ చేసే పారడాక్స్ మాగెల్లాన్ మరియు స్పెక్ట్రా SP సిరీస్ వైర్‌లెస్ మరియు విస్తరించదగిన భద్రతా వ్యవస్థల కోసం సమగ్ర ఇన్‌స్టాలేషన్ గైడ్. సెటప్, ప్రోగ్రామింగ్ మరియు స్పెసిఫికేషన్‌లను కలిగి ఉంటుంది.