OWON XSA1015-TG

OWON XSA1015-TG స్పెక్ట్రమ్ ఎనలైజర్ యూజర్ మాన్యువల్

Model: XSA1015-TG | Frequency Range: 9 kHz - 1.5 GHz

1. పరిచయం

The OWON XSA1015-TG is a high-performance spectrum analyzer designed for precise measurement and analysis of electrical signals. This instrument features a 10.4-inch TFT LCD touch screen, a frequency range from 9 kHz to 1.5 GHz, and an integrated tracking generator. It is suitable for various applications including signal distortion analysis, modulation analysis, spectral purity assessment, and EMI pre-compliance testing. This manual provides essential information for the safe and efficient operation of your device.

Key features of the XSA1015-TG include:

  • ఫ్రీక్వెన్సీ పరిధి: 9 kHz నుండి 1.5 GHz
  • Displayed Average Noise Level (DANL): -150 dBm
  • Phase Noise: -85 dBc/Hz @1 GHz and 10 KHz offset
  • మొత్తం Amplitude Accuracy: <1.5 dB
  • Minimum Resolution Bandwidth (RBW): 10 Hz
  • Integrated 1.5 GHz Tracking Generator
  • 10.4-inch TFT LCD Display for clear visualization
OWON XSA1015-TG Spectrum Analyzer front view with 150dBm Displayed Average Noise Level text overlay

మూర్తి 1: ముందు view of the OWON XSA1015-TG Spectrum Analyzer, highlighting its display and control panel.

2. సెటప్

2.1 అన్‌ప్యాకింగ్ మరియు తనిఖీ

Carefully remove the spectrum analyzer from its packaging. Inspect the device for any signs of physical damage that may have occurred during transit. Retain the packaging materials for future transportation or storage.

2.2 పవర్ కనెక్షన్

Connect the provided power cord to the AC input on the rear panel of the device. Ensure the power source meets the specified requirements: 100V - 240V AC, 50/60Hz. The power input is located on the rear of the unit, typically near the fuse holder.

వెనుక మరియు వైపు view of the OWON XSA1015-TG Spectrum Analyzer, showing power input and ventilation

చిత్రం 2: వెనుక మరియు వైపు views of the spectrum analyzer, illustrating the power input and ventilation.

2.3 Connecting RF Input and Tracking Generator Output

The front panel features the RF Input and Tracking Generator Output connectors. Both are N-type female connectors with a 50 Ω impedance.

  • RF ఇన్‌పుట్: Connect the signal to be analyzed to the RF Input connector. Observe the maximum safe reverse level of +30 dBm / 50 VDC.
  • Tracking Generator Output: Use this connector to output a tracking signal for characterization of devices under test. The maximum safe reverse level is +20 dBm / 50 VDC.
Close-up of the front panel connectors on the OWON XSA1015-TG, showing RF Input and GEN Output

మూర్తి 3: వివరంగా view of the RF Input and Tracking Generator Output connectors on the front panel.

2.4 కమ్యూనికేషన్ పోర్టులు

The rear panel provides various communication ports for external connectivity:

  • USB హోస్ట్: For connecting USB storage devices to save data.
  • USB DEVICE: For connecting the analyzer to a computer.
  • LAN: For network connectivity and remote control.
  • వీజీఏ: బాహ్య ప్రదర్శనను కనెక్ట్ చేయడానికి.
  • ఇయర్ ఫోన్ పోర్ట్: ఆడియో అవుట్‌పుట్ కోసం.
  • 10 M Reference Input: 50 Ω, N-type female connector for an external 10 MHz reference clock.
వెనుక view of the OWON XSA1015-TG Spectrum Analyzer, showing various communication ports

Figure 4: Rear panel of the spectrum analyzer, displaying the communication and reference input ports.

3. ఆపరేటింగ్ సూచనలు

3.1 Powering On and Basic Interface

Press the 'On/Off' button on the front panel to power on the device. The 10.4-inch TFT LCD will display the main measurement interface. The interface is designed with clear color, size, and shape distinctions for buttons and function areas, facilitating quick adjustments.

3.2 Setting Frequency Parameters

To set the frequency range for your measurement:

  1. నొక్కండి FREQ నియంత్రణ ప్యానెల్‌లోని బటన్.
  2. Use the soft keys on the display or the numeric keypad to enter values for:
    • Center Freq: Sets the center frequency of the displayed span.
    • Start Freq: Sets the lowest frequency of the displayed span.
    • Stop Freq: Sets the highest frequency of the displayed span.
    • పరిధి: Sets the frequency range displayed on the screen.
  3. Adjust the Resolution Bandwidth (RBW) by pressing the BW button and selecting the desired value. The minimum RBW is 10 Hz.
OWON XSA1015-TG Spectrum Analyzer display showing a signal trace and measurement settings

Figure 5: The spectrum analyzer display showing a typical signal measurement with frequency and ampలిట్యూడ్ సెట్టింగులు.

3.3 సెట్టింగ్ Amplitude Parameters

To control the vertical scale of the display:

  1. నొక్కండి AMPTD బటన్.
  2. సర్దుబాటు చేయండి సూచన స్థాయి to set the top line of the display in dBm.
  3. సర్దుబాటు చేయండి క్షీణత to prevent input overload and optimize the signal-to-noise ratio.

3.4 Using the Tracking Generator

The integrated tracking generator can be used to characterize the frequency response of filters, amplifiers, and other RF components.

  1. Connect the Tracking Generator Output to the input of the device under test (DUT).
  2. Connect the output of the DUT to the RF Input of the spectrum analyzer.
  3. Enable the tracking generator function through the menu.
  4. Set the desired output power level (range: -30 dBm to 0 dBm).
  5. The spectrum analyzer will sweep synchronously with the tracking generator, displaying the DUT's frequency response.

3.5 Saving and Recalling Data

To save measurement data or instrument settings:

  1. Insert a USB storage device into the USB HOST port on the front panel.
  2. నొక్కండి సేవ్ చేయండి నియంత్రణ ప్యానెల్‌లోని బటన్.
  3. Follow the on-screen prompts to save the current trace, screenshot, or instrument settings to the USB device.
  4. To recall saved data, press the గుర్తుచేసుకోండి button and select the desired file from the USB device.

4. నిర్వహణ

4.1 శుభ్రపరచడం

To clean the instrument, use a soft, damp cloth. Do not use abrasive cleaners or solvents that could damage the display or casing. Ensure the device is powered off and disconnected from the power source before cleaning.

4.2 పర్యావరణ పరిస్థితులు

For optimal performance and longevity, operate the OWON XSA1015-TG within the following environmental conditions:

  • ఆపరేటింగ్ ఉష్ణోగ్రత: 0 °C నుండి 40 °C
  • నిల్వ ఉష్ణోగ్రత: -20 °C నుండి 60 °C
  • Ensure adequate ventilation around the device. The rear panel includes heat vents to facilitate rapid heat dissipation during prolonged use.

4.3 భద్రతా జాగ్రత్తలు

కింది భద్రతా జాగ్రత్తలను గమనించండి:

  • Do not exceed the maximum safe input levels for the RF Input (+30 dBm / 50 VDC) and Tracking Generator Output (+20 dBm / 50 VDC).
  • The instrument contains no user-serviceable components inside. Refer all servicing to qualified personnel.
  • పరికరం యొక్క సరైన గ్రౌండింగ్ నిర్ధారించుకోండి.

5. ట్రబుల్షూటింగ్

This section addresses common issues you might encounter with the OWON XSA1015-TG Spectrum Analyzer.

సమస్యసాధ్యమైన కారణంపరిష్కారం
పరికరం పవర్ ఆన్ చేయదుNo power supply; Power cord not connected; Blown fuseCheck power cord connection; Verify power outlet; Inspect and replace fuse if necessary (refer to qualified personnel).
సిగ్నల్ ప్రదర్శించబడలేదుInput signal too low; Incorrect frequency settings; RF input not connectedIncrease input signal level; Adjust Reference Level; Verify frequency span and center frequency; Ensure RF input is securely connected.
Display is frozen or unresponsiveSoftware error; Temporary glitchRestart the device by powering it off and on. If the issue persists, contact support.
Cannot save data to USBUSB drive not recognized; USB drive full or corruptedEnsure USB drive is properly inserted; Try a different USB drive; Format the USB drive (this will erase all data).

If you encounter issues not listed here or if the suggested solutions do not resolve the problem, please contact OWON customer support for further assistance.

6. స్పెసిఫికేషన్లు

The following table details the technical specifications of the OWON XSA1015-TG Spectrum Analyzer.

పరామితిస్పెసిఫికేషన్
మోడల్XSA1015-TG
ఫ్రీక్వెన్సీ రేంజ్9 kHz - 1.5 GHz
Displayed Average Noise Level (DANL)-150 dBm
దశ శబ్దం-85 dBc/Hz @1 GHz, 10 KHz offset
మొత్తం Amplitude ఖచ్చితత్వం<1.5 డిబి
Minimum Resolution Bandwidth (RBW)10 Hz
Tracking Generator Output Frequency Range100 kHz - 1.5 GHz
Tracking Generator Output Power Level Range-30 dBm - 0 dBm
ప్రదర్శించు10.4 అంగుళాల TFT LCD
RF ఇన్‌పుట్ కనెక్టర్50 Ω, N-type female
Tracking Generator Output Connector50 Ω, N-type female
10 M Reference Input50 Ω, N-type female
కమ్యూనికేషన్ పోర్టులుUSB HOST, USB DEVICE, LAN, earphone port, VGA
విద్యుత్ సరఫరా100V - 240V AC, 50/60Hz
బరువు5 కిలోలు (సుమారు 11 పౌండ్లు)
ఆపరేటింగ్ ఉష్ణోగ్రత0 °C - 40 °C
నిల్వ ఉష్ణోగ్రత-20 °C - 60 °C
సర్టిఫికేషన్EMC, IEC 61010-1:2000-1

7. వారంటీ మరియు మద్దతు

7.1 వారంటీ సమాచారం

OWON products are typically covered by a limited warranty against defects in materials and workmanship. The specific terms and duration of your warranty may vary based on your region and point of purchase. Please refer to the warranty card included with your product or contact your local OWON distributor for detailed warranty information.

7.2 సాంకేతిక మద్దతు

For technical assistance, troubleshooting, or service inquiries, please contact OWON customer support. You can typically find contact information on the official OWON website or through your product's documentation. When contacting support, please have your product model number (XSA1015-TG) and serial number ready.

మీరు వీటిని కూడా సందర్శించవచ్చు OWON Store on Amazon అదనపు ఉత్పత్తి సమాచారం మరియు వనరుల కోసం.

సంబంధిత పత్రాలు - XSA1015-TG

ముందుగాview Руководство пользователя анализатора спектра OWON XSA815-TG с генератором слежения
Данное руководство пользователя содержит подробные инструкции и спецификации для анализатора спектра OWON XSA815-TG с генератором слежения, охватывая настройку, эксплуатацию, измерения и устранение неполадок.
ముందుగాview ఓవాన్ HSA1000 సిరీస్ హ్యాండ్‌హెల్డ్ స్పెక్ట్రమ్ ఎనలైజర్ యూజర్ మాన్యువల్
ఓవాన్ HSA1000 సిరీస్ హ్యాండ్‌హెల్డ్ స్పెక్ట్రమ్ ఎనలైజర్ కోసం యూజర్ మాన్యువల్, HSA1016, HSA1016-TG, HSA1036, HSA1036-TG, HSA1075, మరియు HSA1075-TG మోడల్‌ల కోసం స్పెసిఫికేషన్‌లు, ఆపరేషన్, భద్రతా జాగ్రత్తలు మరియు ట్రబుల్షూటింగ్ వివరాలను అందిస్తుంది.
ముందుగాview ఫంక్షన్ జనరేటర్‌తో కూడిన ఓవాన్ SDS1102+ డిజిటల్ ఓసిల్లోస్కోప్
ఓవాన్ SDS1102+ డిజిటల్ ఓసిల్లోస్కోప్ యొక్క వివరణాత్మక స్పెసిఫికేషన్లు మరియు లక్షణాలు, దాని బ్యాండ్‌విడ్త్‌తో సహా, లుampలింగ్ రేటు, రికార్డ్ పొడవు, ఆటోమేటిక్ కొలతలు మరియు వేవ్‌ఫార్మ్ జనరేటర్ సామర్థ్యాలు. పత్రం చేర్చబడిన ఉపకరణాలను కూడా జాబితా చేస్తుంది.
ముందుగాview OWON FDS సిరీస్ త్వరిత గైడ్: వినియోగదారు మాన్యువల్ మరియు ఆపరేషన్ సూచనలు
Get started with your OWON FDS Series oscilloscope. This quick guide covers essential setup, safety, and operational details for its oscilloscope, function generator, power supply, and multimeter features. Visit www.owon.com.hk/download for full support.
ముందుగాview OWON HDS200 Series SCPI Command Protocol Reference
This document details the Standard Commands for Programmable Instruments (SCPI) protocol for the OWON HDS200 Series oscilloscopes, covering horizontal settings, acquisition, channel configuration, triggering, measurements, and function generator control.
ముందుగాview ఓవాన్ FDS సిరీస్ డిజిటల్ ఓసిల్లోస్కోప్ సాంకేతిక లక్షణాలు
Owon FDS సిరీస్ డిజిటల్ ఓసిల్లోస్కోప్‌ల కోసం వివరణాత్మక సాంకేతిక వివరణలు, FDS1102 మరియు FDS1102A మోడల్‌లతో సహా, పనితీరు లక్షణాలు, ట్రిగ్గర్ ఫంక్షన్‌లు, వేవ్‌ఫార్మ్ ఉత్పత్తి, విద్యుత్ సరఫరా మరియు మల్టీమీటర్ సామర్థ్యాలను కవర్ చేస్తాయి.