మాస్టర్ కూల్ 96236

మాస్టర్‌కూల్ 96236 4-వే అల్యూమినియం మానిఫోల్డ్ గేజ్ సెట్ ఇన్‌స్ట్రక్షన్ మాన్యువల్

For R410A, R22, R407C Refrigerant Systems

పరిచయం

This manual provides instructions for the proper setup, operation, and maintenance of your Mastercool 96236 4-Way Aluminum Manifold Gauge Set. This professional-grade tool is designed for use with R410A, R22, and R407C refrigerants in automotive and HVAC/R air conditioning systems. Please read this manual thoroughly before use to ensure safe and efficient operation.

ఉత్పత్తి ముగిసిందిview మరియు భాగాలు

The Mastercool 96236 manifold set includes a robust aluminum manifold block, two 2 1/2" gauges, and a set of hoses designed for various refrigerant applications.

  • Manifold Block: Features a 4-way design with a full 3/8" bore for increased flow. Equipped with ball valves that rotate 90° for quick opening and closing.
  • కొలతలు: Two 2 1/2" gauges (PSI, °F) for precise pressure and temperature readings. Color-coordinated for multi-refrigerant recognition (R410A, R22, R407C).
  • గొట్టాలు: Includes three 36" 1/4" SAE blue, red, and yellow nylon barrier ball valve hoses with manual shut-off valves, and one 36" 3/8" SAE black vacuum hose.
Mastercool 96236 4-Way Aluminum Manifold Gauge Set with Hoses

మూర్తి 1: Mastercool 96236 4-Way Aluminum Manifold Gauge Set. This image displays the complete manifold set, including the central aluminum block with two large gauges (blue for low pressure, red for high pressure), and four color-coded hoses (red, blue, yellow, and black) coiled around the unit. The hoses are equipped with brass fittings and manual shut-off valves. A metal hook for hanging the manifold is visible at the top.

సెటప్ సూచనలు

  1. భాగాలను తనిఖీ చేయండి: Before each use, visually inspect all components for damage, wear, or leaks. Ensure all hose connections are clean and free of debris.
  2. గొట్టాలను కనెక్ట్ చేయండి:
    • కనెక్ట్ చేయండి నీలం గొట్టం to the "LOW" port on the manifold and to the low-side service port of the AC system.
    • కనెక్ట్ చేయండి ఎర్ర గొట్టం to the "HIGH" port on the manifold and to the high-side service port of the AC system.
    • కనెక్ట్ చేయండి yellow hose to the "REF" (refrigerant) port on the manifold. This hose will connect to the refrigerant tank or charging station.
    • కనెక్ట్ చేయండి black vacuum hose to the "VAC" (vacuum) port on the manifold. This hose will connect to a vacuum pump for evacuation.
  3. సురక్షిత కనెక్షన్లు: Hand-tighten all connections, then use a wrench to ensure a snug, leak-free seal. Do not overtighten.

ఆపరేటింగ్ సూచనలు

A. System Evacuation

  1. Ensure all manifold valves are closed.
  2. Connect the black vacuum hose to a vacuum pump.
  3. Open the "LOW" and "HIGH" valves on the manifold.
  4. Start the vacuum pump. Monitor the gauges; they should drop into a vacuum.
  5. Allow the pump to run until the desired vacuum level is achieved, typically for 15-30 minutes after reaching the target vacuum, depending on system size.
  6. Close the "LOW" and "HIGH" valves on the manifold, then turn off the vacuum pump.
  7. Observe the gauges for at least 10-15 minutes to ensure the vacuum holds, indicating no leaks in the system.

B. Refrigerant Charging

  1. Ensure the system has been properly evacuated and holds vacuum.
  2. Connect the yellow hose to the refrigerant tank.
  3. Slightly open the refrigerant tank valve to purge air from the yellow hose by briefly loosening the connection at the manifold's "REF" port until refrigerant escapes, then retighten.
  4. With the engine off (for automotive AC) or system off (for HVAC/R), open the "LOW" valve on the manifold to allow refrigerant to enter the system. Monitor the low-side gauge.
  5. For liquid charging, invert the refrigerant tank and open the "HIGH" valve briefly, then close it. This method is typically used for initial charge or larger systems. Exercise caution with liquid charging.
  6. Once the desired charge is reached, close the "LOW" and "HIGH" valves on the manifold, then close the refrigerant tank valve.
  7. Disconnect the hoses from the service ports.

C. Pressure Testing

  1. Connect the blue and red hoses to the low and high-side service ports, respectively.
  2. Ensure all manifold valves are closed.
  3. Start the AC system and allow it to stabilize.
  4. Open the "LOW" and "HIGH" valves on the manifold.
  5. Read the pressure values on both gauges. Compare these readings to the manufacturer's specifications for the specific refrigerant and ambient temperature.
  6. Close the "LOW" and "HIGH" valves before disconnecting the hoses.

నిర్వహణ

  • శుభ్రపరచడం: After each use, wipe down the manifold and hoses with a clean, dry cloth. Avoid using harsh chemicals that could damage the gauges or hose material.
  • నిల్వ: Store the manifold set in its original blow-molded case in a clean, dry environment to protect it from dust and physical damage.
  • O-Rings and Gaskets: Periodically inspect O-rings and gaskets in the hose fittings for wear or damage. Replace them as needed to prevent leaks.
  • గేజ్ క్రమాంకనం: While gauges are factory calibrated, significant impacts or prolonged use may affect accuracy. If accuracy is suspected, consult a professional for recalibration.

ట్రబుల్షూటింగ్

సమస్యసాధ్యమైన కారణంపరిష్కారం
Gauges not reading correctlyLoose connections, damaged gauge, incorrect refrigerant selected.Check all connections for tightness. Inspect gauges for physical damage. Ensure correct refrigerant scale is being read.
System not holding vacuumLeaks in hoses, manifold, or AC system.Inspect all hose connections and O-rings. Check AC system components for leaks using a leak detector.
Refrigerant not flowingManifold valves closed, hose shut-off valves closed, clogged hose, empty refrigerant tank.Ensure all necessary valves are open. Check refrigerant tank level. Inspect hoses for kinks or blockages.

స్పెసిఫికేషన్లు

  • మోడల్: మాస్టర్ కూల్ 96236
  • Manifold Type: 4-Way Aluminum
  • గేజ్ పరిమాణం: 2 1/2 inches (PSI, °F)
  • శీతలకరణి అనుకూలత: R410A, R22, R407C
  • Hose Configuration: Three 36" 1/4" SAE nylon barrier ball valve hoses (blue, red, yellow) with manual shut-off valves; One 36" 3/8" SAE black vacuum hose.
  • Manifold Bore: Full 3/8"
  • వాల్వ్ రకం: 90° Ball Valve with Teflon Washers
  • మెటీరియల్: Aluminum (manifold block)
  • వస్తువు బరువు: 3 పౌండ్లు
  • UPC: 700376601596

వారంటీ మరియు మద్దతు

Specific warranty details for the Mastercool 96236 are typically provided with the product packaging or can be obtained by contacting Mastercool directly. For technical support or service inquiries, please refer to the contact information provided by Mastercool or your authorized distributor.

సంబంధిత పత్రాలు - 96236

ముందుగాview మాస్టర్‌కూల్ స్పార్టన్ స్మార్ట్ మానిఫోల్డ్ ఆపరేటింగ్ సూచనలు
మాస్టర్‌కూల్ స్పార్టన్ స్మార్ట్ మానిఫోల్డ్ కోసం సమగ్ర ఆపరేటింగ్ సూచనలు మరియు స్పెసిఫికేషన్లు, ఇది ఖచ్చితమైన పీడనం, ఉష్ణోగ్రత మరియు వాక్యూమ్ కొలతలు, డేటా లాగింగ్ మరియు రిఫ్రిజెరాంట్ నిర్వహణ కోసం ఒక డిజిటల్ HVAC మానిఫోల్డ్ గేజ్ సిస్టమ్.
ముందుగాview మాస్టర్‌కూల్ ఆటోమోటివ్ ఎయిర్ కండిషనింగ్ టూల్స్ & ఎక్విప్‌మెంట్ కేటలాగ్
ప్రొఫెషనల్-గ్రేడ్ ఆటోమోటివ్ ఎయిర్ కండిషనింగ్ సర్వీస్ టూల్స్, వాక్యూమ్ పంపులు, రికవరీ మెషీన్లు, లీక్ డిటెక్షన్ పరికరాలు మరియు మరిన్నింటిని కలిగి ఉన్న సమగ్ర మాస్టర్‌కూల్ కేటలాగ్‌ను అన్వేషించండి. మాస్టర్‌కూల్ యొక్క వినూత్న పరిష్కారాలతో మీ ఆటోమోటివ్ మరమ్మతు సామర్థ్యాలను మెరుగుపరచుకోండి.
ముందుగాview మాస్టర్‌కూల్ కాంపాక్ట్ 2-వే అల్యూమినియం మానిఫోల్డ్: ఆపరేటింగ్ సూచనలు మరియు స్పెసిఫికేషన్లు
మాస్టర్‌కూల్ కాంపాక్ట్ 2-వే అల్యూమినియం మానిఫోల్డ్ కోసం సమగ్ర గైడ్, ఇందులో స్పెసిఫికేషన్లు, ఆపరేటింగ్ సూచనలు, భద్రతా హెచ్చరికలు మరియు విడిభాగాల జాబితా ఉన్నాయి. మీ డిజిటల్ మానిఫోల్డ్ గేజ్ సెట్‌ను ఎలా ఉపయోగించాలో, నిర్వహించాలో మరియు ట్రబుల్షూట్ చేయాలో తెలుసుకోండి.
ముందుగాview మాస్టర్‌కూల్ 69365 ట్విన్ టర్బో రిఫ్రిజెరాంట్ రికవరీ సిస్టమ్ పార్ట్స్ బ్రేక్‌డౌన్
మాస్టర్‌కూల్ 69365 ట్విన్ టర్బో రిఫ్రిజెరాంట్ రికవరీ సిస్టమ్ కోసం సమగ్ర భాగాల జాబితా, 50 lb DOT ట్యాంక్ మోడల్ కోసం భాగాలు, వివరణలు మరియు పార్ట్ నంబర్‌లను వివరిస్తుంది.
ముందుగాview మాస్టర్‌కూల్ స్పార్టన్ స్మార్ట్ మానిఫోల్డ్ ఆపరేటింగ్ సూచనలు
మాస్టర్‌కూల్ స్పార్టన్ స్మార్ట్ మానిఫోల్డ్ కోసం సమగ్ర ఆపరేటింగ్ సూచనలు, సెటప్, వినియోగం, లీక్ టెస్టింగ్ మరియు డేటా లాగింగ్ వంటి లక్షణాలు మరియు నిర్వహణను కవర్ చేస్తాయి.
ముందుగాview మాస్టర్‌కూల్ మొబైల్ ఎలక్ట్రానిక్ ఛార్జింగ్ స్టేషన్ - ఆపరేషన్ మరియు సూచనలు
మాస్టర్‌కూల్ మొబైల్ ఎలక్ట్రానిక్ ఛార్జింగ్ స్టేషన్ కోసం సెటప్, తరలింపు మరియు ఛార్జింగ్ విధానాలతో సహా వివరణాత్మక సూచనలు మరియు ఆపరేషన్ గైడ్. వాక్యూమ్ పంప్, ఛార్జింగ్ స్కేల్ మరియు మానిఫోల్డ్ ఫీచర్లు.