1. పరిచయం
The Logicbus Z-SG is a versatile conditioner and isolator designed for strain gauge applications. It features a single input compatible with 4 or 6-wire load cells, providing analog voltage or current output, and supports Modbus RTU communication. This module is ideal for industrial measurement and control systems requiring precise signal conditioning.
ముఖ్య లక్షణాలు ఉన్నాయి:
- 1 input for 4 or 6-wire load cells with a configurable range of 1 to 64 mV/V.
- 1 analog output, configurable for current (0/4 to 20 mA) or voltage (0 to 5/10 Vdc).
- High 24-bit resolution for accurate measurements.
- Modbus RTU communication for integration into control systems (requires Z-PC-DINAL2-17.5).
- Flexible power supply options: 10 to 40 Vdc or 19 to 28 Vac.

మూర్తి 1: ముందు view of the Logicbus Z-SG Strain Gauge Input Module, showing terminal blocks and status indicators.
2. సెటప్ మరియు ఇన్స్టాలేషన్
Proper installation is crucial for the reliable operation of the Z-SG module. Ensure all connections are secure and follow local electrical codes.
2.1 విద్యుత్ సరఫరా కనెక్షన్
The Z-SG module accepts a wide range of power inputs. Connect the power supply to the designated terminals:
- DC పవర్: 10 నుండి 40 Vdc
- AC పవర్: 19 నుండి 28 ఖాళీలు
Ensure the power source meets the specified voltage and current requirements to prevent damage to the module.
2.2 Strain Gauge Input Wiring
Connect your 4-wire or 6-wire load cell to the strain gauge input terminals. Refer to the module's labeling for correct pin assignments for excitation, signal, and sense lines.

మూర్తి 2: టాప్ view of the Z-SG module, illustrating the wiring terminals for power, strain gauge input, and communication.
2.3 Analog Output Wiring
Connect the analog output to your receiving device (e.g., PLC, data acquisition system). The output can be configured for either current or voltage:
- ప్రస్తుత అవుట్పుట్: 0/4 నుండి 20 mA
- వాల్యూమ్tagఇ అవుట్పుట్: 0 to 5 Vdc or 0 to 10 Vdc
2.4 మోడ్బస్ RTU కమ్యూనికేషన్
For Modbus RTU communication, connect the module to a compatible RS-485 network. Note that a Z-PC-DINAL2-17.5 module may be required for proper integration. Refer to the Modbus communication protocol documentation for addressing and register details.
2.5 కాన్ఫిగరేషన్
The input range (1 to 64 mV/V) and output type (current/voltage) are configurable via the RS-232 port using free software provided by the manufacturer. Connect the module to a computer via RS-232 and use the software to set the desired parameters for your application.

మూర్తి 3: Functional block diagram illustrating the internal components and signal flow of the Z-SG module, including power supply, input, output, and Modbus communication.
3. ఆపరేషన్
Once properly installed and configured, the Z-SG module will convert the strain gauge signal into the specified analog output or transmit data via Modbus RTU.
3.1 Signal Conversion
The module continuously monitors the strain gauge input and converts the mV/V signal into a proportional analog current or voltage output, as configured. This output can then be read by a control system to monitor load or force.
3.2 మోడ్బస్ కమ్యూనికేషన్
For systems utilizing Modbus RTU, the module acts as a slave device, providing digital access to measured values and configuration parameters. Ensure your Modbus master device is correctly configured to communicate with the Z-SG module's address and baud rate.

మూర్తి 4: Example application diagram demonstrating the Z-SG module integrated into a weighing system, connecting load cells to a control unit via Modbus RTU and providing an analog output to a display.
4. నిర్వహణ
The Logicbus Z-SG module is designed for long-term, reliable operation with minimal maintenance. However, periodic checks can help ensure optimal performance.
- దృశ్య తనిఖీ: Periodically inspect the module and its connections for any signs of physical damage, loose wiring, or corrosion.
- పర్యావరణ పరిస్థితులు: అకాల వైఫల్యాన్ని నివారించడానికి ఆపరేటింగ్ వాతావరణం పేర్కొన్న ఉష్ణోగ్రత మరియు తేమ పరిధిలో ఉండేలా చూసుకోండి.
- శుభ్రపరచడం: If necessary, gently clean the exterior of the module with a soft, dry cloth. Do not use harsh chemicals or abrasive materials.
- రీకాలిబ్రేషన్: Depending on the application and required accuracy, periodic recalibration of the strain gauge system, including the Z-SG module, may be necessary. Refer to your system's calibration procedures.
5. ట్రబుల్షూటింగ్
If you encounter issues with your Z-SG module, consider the following troubleshooting steps:
- శక్తి లేదు: Check the power supply connections and ensure the voltage is within the specified range (10-40 Vdc or 19-28 Vac). Verify that the power indicator LED on the module is illuminated.
- తప్పు అవుట్పుట్:
- Verify the strain gauge wiring for correct polarity and secure connections.
- Confirm the strain gauge is functioning correctly.
- Check the module's configuration via the RS-232 software to ensure the input range and output type are set correctly for your application.
- Ensure the receiving device (e.g., PLC) is correctly configured to read the analog output signal (current or voltagమరియు).
- Modbus Communication Issues:
- Verify RS-485 wiring, including termination resistors if necessary.
- Check the Modbus address and baud rate settings in both the Z-SG module (via configuration software) and the Modbus master device.
- Ensure the Z-PC-DINAL2-17.5 module, if used, is correctly installed and functioning.
- Observe the RX/TX indicator LEDs on the module for data transmission activity.
- Error Indicator (ERR LED): If the ERR LED is illuminated, consult the detailed product manual or contact technical support for specific error code interpretations.

మూర్తి 5: వైపు view of the Z-SG module, highlighting the status LEDs (ERR, PWR, RX, TX, COM) which provide visual feedback on the module's operational status and communication activity.
6. స్పెసిఫికేషన్లు
| ఫీచర్ | విలువ |
|---|---|
| మోడల్ సంఖ్య | Z-SG |
| ఇన్పుట్ రకం | 1 input for 4 or 6-wire load cells |
| ఇన్పుట్ పరిధి | 1 ~ 64 mV/V (configurable) |
| అనలాగ్ అవుట్పుట్ | Configurable: 0/4 ~ 20 mA or 0 ~ 5/10 Vdc |
| రిజల్యూషన్ | 24-బిట్ |
| కమ్యూనికేషన్ | Modbus RTU (requires Z-PC-DINAL2-17.5 for full functionality) |
| విద్యుత్ సరఫరా | 10 ~ 40 Vdc or 19 ~ 28 Vac |
| ఉత్పత్తి కొలతలు | 6.89 x 3.94 x 4.41 అంగుళాలు |
| బరువు | 4.94 ఔన్సులు |
| తయారీదారు | Seneca (Brand: Logicbus) |
7. వారంటీ మరియు మద్దతు
For information regarding product warranty, technical support, or additional documentation, please contact Logicbus Inc. or visit their official webసైట్.
మీరు మరిన్ని వివరాలు మరియు సంప్రదింపు వివరాలను ఇక్కడ కనుగొనవచ్చు Logicbus Store on Amazon.