పరిచయం
The ITECH IT6720 is a high-performance digital-control variable DC power supply designed for a wide range of applications, from laboratory research to production line testing. It provides stable and precise voltage and current output with automatic constant current (CC) and constant voltage (CV) conversion modes. Equipped with multiple protection functions, this power supply ensures safe and reliable operation.

మూర్తి 1: ముందు view of the ITECH IT6720 Variable DC Power Supply.
ఉత్పత్తి ముగిసిందిview
ముందు ప్యానెల్ లేఅవుట్

మూర్తి 2: వివరంగా view of the front panel, showing the CC/CV indicators, OCP/OVP indicators, memory save buttons, keyboard lock, voltage/current adjust knob, output ON/OFF button, and display switch button.
వెనుక ప్యానెల్ లేఅవుట్

మూర్తి 3: వివరంగా view of the rear panel, indicating the power switch, AC power input, 9-pin connector (for factory use only), and cooling fan.
సెటప్
- పవర్ కనెక్షన్: Connect the supplied power cord to the AC power input on the rear panel (Figure 3). Ensure the power switch is in the OFF position before connecting.
- వాల్యూమ్tagఇ ఎంపిక: వాల్యూమ్ని ధృవీకరించండిtage selector switch on the rear panel is set to the correct local AC voltage (110V or 220V). Adjust if necessary using a small flat-head screwdriver.
- అవుట్పుట్ కనెక్షన్లు: Connect your load to the output terminals on the front panel. The red terminal is positive (+), the black terminal is negative (-), and the green terminal is ground. Ensure secure connections.
- ప్రారంభ పవర్ ఆన్: Flip the power switch on the rear panel to the ON position. The display on the front panel should illuminate.
Video 1: A brief demonstration of the ITECH IT6700 series DC power supply, including power-on and basic operation.
ఆపరేటింగ్ సూచనలు
- సెట్టింగ్ వాల్యూమ్tagఇ మరియు ప్రస్తుత: Use the large rotary knob to adjust the voltage and current values. Press the 'Shift' button to toggle between coarse and fine adjustment modes for precise control. The display will show the set values.
- Output ON/OFF: Press the 'On/off' button to enable or disable the output. The display will indicate if the output is active.
- CC/CV Automatic Conversion: The power supply automatically switches between Constant Voltage (CV) and Constant Current (CC) modes depending on the load. The corresponding indicator (CC or CV) on the display will light up.
- రక్షణ విధులు: The unit is equipped with Over Current Protection (OCP), Over Voltage Protection (OVP), and Over Temperature Protection (OTP). If any of these conditions are met, the output will shut down and the respective indicator will light up.
- మెమరీ విధులు: Use the 'Save' and 'Prog' buttons (A, B, C, D) to store and recall frequently used voltage and current settings. Refer to the detailed manual for specific programming steps.
- కీబోర్డ్ లాక్: The 'Lock' button can be used to prevent accidental changes to settings during operation.
వీడియో 2: ఒక ఓవర్view of the IT6700 DC Power Supply's features, including its bright display, high resolution, and CV/CC modes.

Figure 4: The key lock feature helps prevent accidental changes to settings.

Figure 5: Table illustrating the different adjustment step values for voltage and current (e.g., 1V, 0.1V, 0.01V for voltage; 1A, 0.1A, 0.01A, 0.001A for current).
నిర్వహణ
ఫ్యూజ్ ప్రత్యామ్నాయం
The ITECH IT6720 power supply is equipped with a replaceable fuse for protection against overcurrent. If the unit fails to power on or experiences unexpected shutdowns, the fuse may need replacement. The fuse holder is located on the rear panel, near the AC power input.
- పవర్ డిస్కనెక్ట్ చేయండి: Ensure the power supply is completely disconnected from the AC mains before attempting any maintenance.
- Locate Fuse Holder: Identify the fuse holder on the rear panel (refer to Figure 3). It is typically a small, cylindrical cap that can be twisted or pulled out.
- Remove Old Fuse: Use a small flat-head screwdriver or your fingernail to gently pry open or twist the fuse holder cap. Carefully remove the old fuse.
- Check Fuse Rating: The required fuse rating is printed on the rear panel near the fuse holder. For 110V AC operation, the fuse is typically 3.15A/250V. For 220V AC operation, it is 1.5A/250V. Always replace with a fuse of the exact same type and rating.
- కొత్త ఫ్యూజ్ని చొప్పించండి: Place the new fuse into the fuse holder cap and reinsert it into the power supply, ensuring it is securely seated.
- పవర్ని మళ్లీ కనెక్ట్ చేయండి: Reconnect the power supply to the AC mains and test its operation.
Note: If the fuse blows repeatedly, there may be an underlying issue with the unit or your electrical setup. Contact technical support for assistance.
స్పెసిఫికేషన్లు
| స్పెసిఫికేషన్ | విలువ |
|---|---|
| అవుట్పుట్ వాల్యూమ్tage | 0-60V |
| అవుట్పుట్ కరెంట్ | 0-5A |
| శక్తి | 0-100W |
| వాల్యూమ్tagఇ రిజల్యూషన్ | 0.01V |
| ప్రస్తుత రిజల్యూషన్ | 0.001A |
| వాల్యూమ్tagఇ ఖచ్చితత్వం | <0.05%+10mV |
| ప్రస్తుత ఖచ్చితత్వం | <0.1%+2mA |
| ఉత్పత్తి కొలతలు (L x W x H) | 11.1 x 6.9 x 3.5 అంగుళాలు |
| వస్తువు బరువు | 7.7 పౌండ్లు |
| శీతలీకరణ పద్ధతి | గాలి |
For a complete list of specifications, please refer to the official product documentation.

Figure 6: Product dimensions of the ITECH IT6720.

Figure 7: Power curve illustrating the voltage and current capabilities within the rated power.
ట్రబుల్షూటింగ్
- యూనిట్ పవర్ ఆన్ చేయదు:
1. Check if the power cord is securely connected to both the unit and the AC outlet.
2. Verify the power switch on the rear panel is in the ON position.
3. Inspect the fuse on the rear panel. If blown, replace it with a fuse of the correct rating (refer to Maintenance section). - అవుట్పుట్ వాల్యూమ్ లేదుtagఇ/కరెంట్:
1. Ensure the output ON/OFF button on the front panel is enabled.
2. Check if any protection indicators (OCP, OVP, OTP) are lit. If so, resolve the overload/overvoltage/overtemperature condition and reset the unit.
3. వాల్యూమ్ అని ధృవీకరించండిtage and current settings are not set to zero. - Difficulty with user interface/modes:
The IT6720 uses a single control knob with multiple modes. Refer to the detailed user manual (PDF link provided in product documents) for a comprehensive explanation of each mode (Mode A, B, C, D) and how to navigate them using the 'Shift' and 'Setup' buttons. Practice adjusting values in different modes to become familiar with the interface.
వారంటీ మరియు మద్దతు
ITECH provides professional technical support for its products both before and after sale. For any technical inquiries, operational assistance, or warranty claims, please contact ITECH customer service directly.
Refer to the official ITECH website or the documentation included with your product for the most up-to-date contact information and warranty details.

Figure 8: Contact information for ITECH Technical Team.





