1. పరిచయం
The Sygonix SY-4504968 Digital Timer is designed for automated control of electrical devices, such as lighting, in homes or offices. This versatile timer offers 15 programmable configurations, including weekly settings, allowing for up to 20 switching times per day, totaling 140 switching points per week. It features automatic summer and winter time adjustment, a countdown function, and a random mode. The timer supports both flush and surface mounting.
Please read this manual thoroughly before installation and operation to ensure correct usage and to prevent damage.

మూర్తి 1: ముందు view of the Sygonix SY-4504968 Digital Built-in Timer, showing the digital display and the main power button.
2. భద్రతా సూచనలు
- స్థానిక ఎలక్ట్రికల్ కోడ్లు మరియు నిబంధనలకు అనుగుణంగా అర్హత కలిగిన ఎలక్ట్రీషియన్ ద్వారా ఇన్స్టాలేషన్ నిర్వహించాలి.
- Ensure the power supply is disconnected before installation, maintenance, or any wiring work.
- The device requires a neutral wire for operation. Verify its presence in your electrical box.
- Do not exceed the maximum load capacity of 1800 W.
- పరికరాన్ని తేమ, తీవ్రమైన ఉష్ణోగ్రతలు లేదా ప్రత్యక్ష సూర్యకాంతికి గురిచేయవద్దు.
- పరికరాన్ని విడదీయడానికి లేదా సవరించడానికి ప్రయత్నించవద్దు. అన్ని సర్వీసింగ్లను అర్హత కలిగిన సిబ్బందికి సూచించండి.
3. ప్యాకేజీ విషయాలు
ప్యాకేజీలో అన్ని అంశాలు ఉన్నాయని నిర్ధారించుకోండి:
- Sygonix SY-4504968 Digital Built-in Timer
- Surface mount frame
- మౌంటు మరలు మరియు గోడ ప్లగ్స్
- ఇన్స్ట్రక్షన్ మాన్యువల్
4. ఉత్పత్తి ముగిసిందిview
The timer features a digital display and control buttons located behind a protective cover.

మూర్తి 2: క్లోజ్-అప్ view of the timer's digital display, showing time, day (TU for Tuesday), and 'PROG' and 'ON' indicators.

మూర్తి 3: The timer with its protective cover open, revealing the control buttons for programming and settings.
4.1. ప్రదర్శన సూచికలు
- సమయ ప్రదర్శన: Shows current time in HH:MM format.
- రోజు సూచిక: Displays the current day of the week (e.g., MO, TU, WE).
- ప్రోగ్: Indicates that a program is active or being set.
- ఆన్/ఆఫ్: Indicates the current switching state of the connected device.
4.2. Control Buttons (behind cover)
- Clock/Set Button: Used to set the current time and day.
- PROG బటన్: Enters program setting mode.
- RND (Random) Button: Activates/deactivates random switching mode.
- CD (Countdown) Button: Activates/deactivates countdown function.
- +/- బటన్లు: Used to adjust values (time, program settings).
- R (Reset) Button: Resets the timer to factory defaults.
5. సంస్థాపన
The timer can be installed either flush-mounted into a wall box or surface-mounted using the provided frame.
5.1. వైరింగ్ రేఖాచిత్రం
ముఖ్యమైన: Ensure the main power supply is switched off before proceeding with any wiring. This device requires a neutral wire connection.
Connect the Live (L), Neutral (N), and Switched Live (L') wires according to the diagram provided with the product. The neutral wire is essential for the timer's internal clock and display to function.
5.2. Flush Mounting
- Prepare a standard wall box (minimum depth of 50mm recommended for easier wiring).
- Connect the electrical wires to the terminals on the back of the timer as per the wiring diagram.
- Carefully push the timer into the wall box, ensuring wires are not pinched.
- అందించిన స్క్రూలను ఉపయోగించి వాల్ బాక్స్కు టైమర్ను భద్రపరచండి.
- Attach the front cover plate.

మూర్తి 4: The digital timer flush-mounted into a wall, blending with the room's decor.
5.3. Surface Mounting
- Attach the surface mount frame to the wall using the provided screws and wall plugs.
- Connect the electrical wires to the terminals on the back of the timer.
- Insert the timer into the surface mount frame, ensuring a secure fit.
- Attach the front cover plate.

మూర్తి 5: వైపు view of the timer, illustrating its depth for installation considerations.
6. సెటప్
6.1. Initial Power-On and Reset
After installation and restoring power, the display will light up. If the display is erratic or shows incorrect values, press the R (Reset) button with a pointed object (e.g., a pen tip) to clear all settings and restore factory defaults.
6.2. Setting Current Time and Day
- Open the protective cover to access the control buttons.
- నొక్కండి మరియు పట్టుకోండి Clock/Set button for approximately 3 seconds until the time display flashes.
- ఉపయోగించండి +/- గంటను సర్దుబాటు చేయడానికి బటన్లు. నొక్కండి Clock/Set మళ్ళీ నిర్ధారించి నిమిషాలకు తరలించండి.
- ఉపయోగించండి +/- నిమిషాలను సర్దుబాటు చేయడానికి బటన్లు. నొక్కండి Clock/Set again to confirm and move to day.
- ఉపయోగించండి +/- buttons to select the current day of the week (MO, TU, WE, TH, FR, SA, SU).
- నొక్కండి Clock/Set one last time to save the settings and exit the time setting mode.
6.3. Automatic Summer/Winter Time Adjustment
The timer is equipped with an automatic summer/winter time adjustment feature. This function typically activates automatically based on pre-programmed dates. No manual intervention is usually required for this feature.
7. ఆపరేటింగ్
7.1. Programming Weekly Schedules
The timer allows for up to 15 different program configurations, with 20 switching times per day, totaling 140 switching points per week.
- నొక్కండి PROG button to enter program setting mode. The display will show '1 ON' (for program 1, switch-on time).
- ఉపయోగించండి +/- buttons to set the desired switch-on hour. Press PROG నిర్ధారించి నిమిషాలకు తరలించడానికి.
- ఉపయోగించండి +/- buttons to set the desired switch-on minutes. Press PROG to confirm and move to day selection.
- ఉపయోగించండి +/- buttons to select the day(s) for this program. You can choose individual days, blocks of days (e.g., MO-FR), or all days. Press PROG నిర్ధారించడానికి.
- The display will now show '1 OFF' (for program 1, switch-off time). Repeat steps 2-4 to set the switch-off time and day(s) for this program.
- After setting the 'OFF' time, press PROG again to move to the next program ('2 ON') or to exit program setting mode if no more programs are needed.
- To exit program mode at any time, press the Clock/Set బటన్.
7.2. కౌంట్డౌన్ ఫంక్షన్
The countdown function allows you to set a specific duration after which the connected device will switch ON or OFF.
- నొక్కండి CD (Countdown) button. The display will show 'CD' and a default countdown time.
- ఉపయోగించండి +/- buttons to adjust the desired countdown duration (hours and minutes).
- నొక్కండి CD again to start the countdown. The device will switch its state (ON to OFF, or OFF to ON) once the countdown finishes.
- కౌంట్డౌన్ను రద్దు చేయడానికి, నొక్కండి CD button again during the countdown.
7.3. Random Mode
The random mode switches the connected device ON and OFF at irregular intervals, simulating presence for security purposes.
- నొక్కండి RND (Random) button. The display will show 'RND'.
- The timer will now activate and deactivate the connected device at random times within a predefined period (e.g., 30 minutes to 2 hours).
- To deactivate random mode, press the RND button again. The 'RND' indicator will disappear.
8. నిర్వహణ
- పరికరాన్ని మృదువైన, పొడి వస్త్రంతో శుభ్రం చేయండి. రాపిడి క్లీనర్లను లేదా ద్రావకాలను ఉపయోగించవద్దు.
- The internal battery (if present for memory backup) is typically long-lasting and not user-replaceable. If the timer loses settings during power outages, the battery may need professional replacement.
9. ట్రబుల్షూటింగ్
| సమస్య | సాధ్యమైన కారణం | పరిష్కారం |
|---|---|---|
| టైమర్ డిస్ప్లే ఖాళీగా ఉంది. | No power supply; internal battery depleted. | Check power connection. If power is present, the internal battery may need replacement (professional service recommended). |
| Timer does not switch connected device. | Incorrect wiring; program not activated; device faulty. | Verify wiring (especially neutral connection). Ensure programs are correctly set and activated. Test the connected device independently. |
| పవర్ ఆఫ్ అయిన తర్వాత సెట్టింగ్లు పోతాయిtage. | Internal backup battery depleted. | The internal battery needs replacement. Contact customer support or a qualified technician. |
| Cannot set time/program. | Incorrect button sequence; device frozen. | Refer to the 'Setup' and 'Operating' sections. Press the R (Reset) button to clear and try again. |
10. స్పెసిఫికేషన్లు
- మోడల్: SY-4504968
- తయారీదారు: సిగోనిక్స్
- వాల్యూమ్tage: 230 వోల్ట్లు
- గరిష్టంగా లోడ్: 1800 W
- ఉత్పత్తి కొలతలు (L x W x H): 12 x 9 x 8 సెం.మీ
- బరువు: 230 గ్రాములు
- ప్రదర్శన రకం: డిజిటల్
- ప్రోగ్రామ్ల సంఖ్య: 15
- Switching Points: Up to 140 per week (20 per day)
- బ్యాటరీలు అవసరం: Yes (for internal clock/memory backup, typically not user-replaceable)
11. వారంటీ మరియు మద్దతు
Sygonix products are manufactured to high-quality standards. For warranty information, please refer to the warranty card included with your purchase or visit the official Sygonix website. For technical support, troubleshooting assistance, or spare parts, please contact your retailer or the Sygonix customer service department.