Circutor M22348.

DHC-96 mVdc Digital Voltmeter Shunt User Manual

Model: M22348. | Brand: Circutor

1. పరిచయం

The Circutor DHC-96 mVdc Digital Voltmeter Shunt (Model M22348.) is a sophisticated digital instrument panel designed for precise monitoring, regulation, and control of electrical variants and process signals. This device is capable of displaying measured electrical values or proportional values of process signals, making it suitable for a wide range of industrial and climate solar installations.

ముఖ్య లక్షణాలు ఉన్నాయి:

  • కొలతలో అధిక ఖచ్చితత్వం.
  • Programmable measurement input.
  • Integrated relay output for control and alarm functions.
  • Universal power supply compatibility (80-270 Vca/cc and 16-36 VCC).
  • Frontal IP 54 protection for enhanced durability.
  • Galvanic insulation between external circuits.
  • Self-configurable decimal point.
  • Designed for panel installation (96 x 49 mm).
Circutor DHC-96 mVdc Digital Voltmeter Shunt with red digital display showing '0.000 A' and control buttons below.

మూర్తి 1: ముందు view of the Circutor DHC-96 mVdc Digital Voltmeter Shunt, showing its digital display and control buttons.

2. సెటప్ మరియు ఇన్‌స్టాలేషన్

Proper installation is crucial for the optimal performance and longevity of your DHC-96 device. Ensure all power sources are disconnected before proceeding with installation.

2.1 ప్యానెల్ మౌంటు

  • Prepare a panel cutout with dimensions of 96 x 49 mm.
  • Insert the DHC-96 unit into the cutout from the front.
  • Secure the unit using the provided mounting clips or brackets from the rear of the panel. Ensure a snug fit to maintain the IP 54 frontal protection rating.

2.2 విద్యుత్ సరఫరా కనెక్షన్

The DHC-96 supports a universal power supply. Connect the power source to the designated terminals on the rear of the unit.

  • For AC/DC power, connect to 80-270 Vca/cc terminals.
  • For DC power, connect to 16-36 VCC terminals.
  • Ensure correct polarity for DC connections.

2.3 Measurement Input Connection

Connect the signal source to the programmable measurement input terminals. Refer to the wiring diagram provided with your specific model for detailed connection points.

  • వాల్యూమ్ కోసంtage measurements, connect the voltagఇ మూలం.
  • For current measurements, connect through a shunt or current transformer as appropriate for your application.
  • Ensure galvanic insulation between external circuits is maintained.

2.4 రిలే అవుట్‌పుట్ కనెక్షన్

The DHC-96 features two output relays for control and alarm functions. Connect these relays to your external control systems or alarm indicators as required.

  • Identify the relay output terminals.
  • Wire the relays according to your application's control logic.
  • Configure alarm delays and interlocking settings via the device's menu.

3. ఆపరేటింగ్ సూచనలు

Once installed and powered, the DHC-96 is ready for operation. The front panel features a digital display and control buttons for configuration and monitoring.

3.1 ప్రదర్శన ముగిసిందిview

The digital display shows the measured electrical variant (e.g., voltage, current, frequency) or the proportional value of a process signal. The unit automatically adjusts the display based on the configured measurement type.

  • DC Systems: Capable of measuring voltage, current, frequency, and other industrial process variables.
  • AC మోడల్‌లు: Perform measurements in True Effective Value (TRMS).
  • దశాంశ బిందువు: The decimal point is self-configurable to suit your measurement precision requirements.

3.2 బటన్ విధులు

The front panel buttons allow for navigation through menus, parameter configuration, and display adjustments. Specific button functions may vary slightly depending on the firmware version.

  • Left/Right Arrows (< / >): Typically used for navigating through menu options or adjusting values.
  • పైకి/క్రిందికి బాణాలు (∧ ∧ లు / ): ఇంక్రిమెంట్ కోసం ఉపయోగించబడిందిasinగ్రా/తగ్గింపుasing values or selecting options.
  • మెనూ/ఎంటర్ బటన్: Used to access the main menu, confirm selections, or save settings.
  • Escape/Back Button: Used to exit a menu or cancel an operation.

3.3 Configuration and Programming

The DHC-96 allows for programming various parameters to suit specific application needs. This includes setting the measurement input type, configuring alarm thresholds, and defining relay behaviors.

  • Access the configuration menu by pressing the Menu/Enter button.
  • బాణం బటన్‌లను ఉపయోగించి మెను ఎంపికల ద్వారా నావిగేట్ చేయండి.
  • Select the desired parameter to modify and adjust its value.
  • Save changes before exiting the menu.
  • Refer to the detailed programming guide (if available separately) for advanced configurations.

4. నిర్వహణ

The DHC-96 is designed for reliable operation with minimal maintenance. Regular inspection and cleaning will help ensure its continued performance.

  • శుభ్రపరచడం: కాలానుగుణంగా ముందు ప్యానెల్‌ను మృదువైన, d తో శుభ్రం చేయండి.amp వస్త్రం. రాపిడి క్లీనర్‌లు లేదా ద్రావకాలను ఉపయోగించవద్దు, ఎందుకంటే అవి డిస్‌ప్లే లేదా సిని దెబ్బతీస్తాయి.asing.
  • తనిఖీ: Regularly inspect the wiring connections for any signs of wear, corrosion, or looseness. Ensure the unit is securely mounted in its panel cutout.
  • పర్యావరణం: Ensure the operating environment remains within the specified temperature and humidity ranges to prevent damage. The IP 54 frontal protection helps against dust and splashing water, but the unit is not designed for immersion.
  • వినియోగదారు-సేవ చేయదగిన భాగాలు లేవు: The DHC-96 contains no user-serviceable parts. Do not attempt to open the casing, as this will void the warranty and may expose you to electrical hazards.

5. ట్రబుల్షూటింగ్

If you encounter issues with your DHC-96, refer to the following common troubleshooting steps. For problems not listed here, contact Circutor technical support.

  • డిస్ప్లే/పవర్ లేదు:
    • Check the power supply connections to ensure they are secure and correctly wired.
    • విద్యుత్ వనరు వాల్యూమ్ అని ధృవీకరించండిtage is within the specified range (80-270 Vca/cc or 16-36 VCC).
    • పవర్ సర్క్యూట్‌లో ఏవైనా ట్రిప్డ్ సర్క్యూట్ బ్రేకర్లు లేదా ఎగిరిన ఫ్యూజ్‌లు ఉన్నాయా అని తనిఖీ చేయండి.
  • సరికాని రీడింగ్‌లు:
    • Ensure the measurement input is correctly connected and the signal source is active.
    • Verify that the device's measurement input type is correctly configured in the settings to match your application (e.g., voltage, current, process signal).
    • Check for any external interference or noise affecting the signal.
    • Confirm the decimal point setting is appropriate for the expected values.
  • రిలే సక్రియం కావడం లేదు:
    • Check the relay output wiring for proper connection to the external control system.
    • Verify the alarm thresholds and relay logic are correctly configured in the device's settings.
    • Ensure the measured value has exceeded or fallen below the set alarm threshold.
    • Check for any configured alarm delays or interlocking conditions that might prevent immediate activation.

6. స్పెసిఫికేషన్లు

గుణంవిలువ
తయారీదారుసర్క్యుటర్
పార్ట్ నంబర్M22348.
అంశం మోడల్ సంఖ్యM22348.
ఉత్పత్తి కొలతలు3.01 x 1.93 x 3.78 అంగుళాలు
వస్తువు బరువు7 ఔన్సులు
రంగునలుపు
శైలిసర్
శక్తి మూలంవిద్యుత్
అంశం ప్యాకేజీ పరిమాణం1
బ్యాటరీలు అవసరమా?నం
ASINB08WL8FMDB
మొదటి తేదీ అందుబాటులో ఉందిఆగస్టు 15, 2023

7. వారంటీ మరియు మద్దతు

For detailed warranty information, please refer to the warranty card included with your product or visit the official Circutor webసైట్. వారంటీ నిబంధనలు మరియు షరతులు ప్రాంతం మరియు ఉత్పత్తిని బట్టి మారవచ్చు.

For technical support, service, or inquiries regarding your DHC-96 mVdc Digital Voltmeter Shunt, please contact Circutor customer service or your authorized dealer. Provide your product model number (M22348.) and serial number (if applicable) when seeking support.

You can find more information and contact details on the official Circutor webసైట్: www.circutor.com

సంబంధిత పత్రాలు - M22348.

ముందుగాview సర్క్యూట్ అర్బన్ & అర్బన్ WB EV ఛార్జింగ్ స్టేషన్ మాన్యువల్
సర్క్యూట్ అర్బన్ మరియు అర్బన్ WB ఎలక్ట్రిక్ వెహికల్ ఛార్జింగ్ స్టేషన్ల కోసం యూజర్ మరియు కాన్ఫిగరేషన్ గైడ్, ఇన్‌స్టాలేషన్, ఆపరేషన్ మరియు సాంకేతిక వివరణలను కవర్ చేస్తుంది.
ముందుగాview సర్క్యుటర్ లైన్-TCPRS1 RS-485/RS-232 నుండి TCP/IP కన్వర్టర్ ఇన్‌స్టాలేషన్ గైడ్
RS-485 లేదా RS-232 భౌతిక వాతావరణాలను ఈథర్నెట్ మరియు/లేదా Wi-Fiకి మార్చడానికి గేట్‌వే అయిన సర్క్యుటర్ లైన్-TCPRS1 కోసం ఇన్‌స్టాలేషన్ గైడ్. లక్షణాలు Web సర్వర్ మరియు ఆండ్రాయిడ్ యాప్ కనెక్టివిటీ.
ముందుగాview సర్క్యూట్ CVM-E3-MINI-ITF-WiEth పవర్ ఎనలైజర్ ఇన్‌స్టాలేషన్ మరియు టెక్నికల్ గైడ్
CIRCUTOR CVM-E3-MINI-ITF-WiEth పవర్ ఎనలైజర్ కోసం సమగ్ర ఇన్‌స్టాలేషన్ గైడ్ మరియు సాంకేతిక వివరణలు. దాని లక్షణాలు, కనెక్షన్ రేఖాచిత్రాలు, విద్యుత్ పారామితి కొలతలు మరియు వివిధ నెట్‌వర్క్ రకాల కోసం ఆపరేషనల్ కీ ఫంక్షన్ల గురించి తెలుసుకోండి.
ముందుగాview సర్క్యూటర్ TCPRS1+ RS-485 నుండి TCP/IP కన్వర్టర్ ఇన్‌స్ట్రక్షన్ మాన్యువల్
సర్క్యూట్ TCPRS1+ RS-485 నుండి TCP/IP కన్వర్టర్‌కు సమగ్ర గైడ్, భద్రత, ఇన్‌స్టాలేషన్, ఆపరేషన్, కమ్యూనికేషన్‌లు (Wi-Fi, ఈథర్నెట్), సాంకేతిక వివరణలు మరియు నిర్వహణను కవర్ చేస్తుంది.
ముందుగాview సర్క్యూట్ బ్రిడ్జ్ LR RS-485 - LoRa™ కన్వర్టర్ ఇన్‌స్ట్రక్షన్ మాన్యువల్
సర్క్యూట్ బ్రిడ్జ్ LR కోసం సమగ్ర సూచన మాన్యువల్, ఇది RS-485 నుండి LoRa™ కన్వర్టర్. ఇన్‌స్టాలేషన్, ఆపరేషన్, సాంకేతిక లక్షణాలు మరియు కాన్ఫిగరేషన్‌ను కవర్ చేస్తుంది.
ముందుగాview సర్క్యూట్ CVM-C5 సిరీస్ పవర్ ఎనలైజర్ ఇన్‌స్ట్రక్షన్ మాన్యువల్
CVM-C5-ITF-485, CVM-C5-MC-485, మరియు CVM-C5-mV-485 మోడల్‌లతో సహా సర్క్యూట్ CVM-C5 సిరీస్ పవర్ ఎనలైజర్‌ల కోసం సూచనల మాన్యువల్. ఇన్‌స్టాలేషన్, ఆపరేషన్, ప్రోగ్రామింగ్ మరియు సాంకేతిక వివరణలపై వివరణాత్మక సమాచారాన్ని అందిస్తుంది.