Energetic B0C7TFN1NP

Energetic 12 Gauge Trip Wire Perimeter Alarm User Manual

Model: B0C7TFN1NP | Brand: Energetic

పరిచయం

The Energetic 12 Gauge Trip Wire Perimeter Alarm is a robust and reusable security device designed to provide early warning against unwanted intrusions. Constructed from high-quality, rust-proof 6061 aluminum, this spring-activated alarm is ideal for protecting campsites, homes, farms, and restricted areas by creating an audible perimeter.

It functions by utilizing a hidden trip wire that, when pulled, activates a loud acoustic alarm, alerting you to potential threats. This device is intended for outdoor use only and is designed to produce a loud noise for alert purposes, not to cause harm.

Energetic 12 Gauge Trip Wire Perimeter Alarm

Image: The Energetic 12 Gauge Trip Wire Perimeter Alarm device, showcasing దాని కాంపాక్ట్ మరియు మన్నికైన డిజైన్.

ప్యాకేజీ కంటెంట్‌లు మరియు భాగాలు

మీ ప్యాకేజీ కింది వాటిని కలిగి ఉండాలి:

Familiarize yourself with the main components of the alarm device:

Diagram of Energetic 12 Gauge Trip Wire Perimeter Alarm components

Image: Labeled diagram of the alarm device, indicating the Pull Ring, Trigger Pin, Firing Pin, Spring/Pin Retainer, Zip-tie Mounts, Mounting Holes, Load Detent, and Breech.

సెటప్ సూచనలు

Follow these steps to properly set up your perimeter alarm:

Three-step installation guide for the Energetic 12 Gauge Trip Wire Perimeter Alarm

Image: Visual guide showing the three main steps for installing the alarm: attaching to a hard object, installing the pin and setting the trip wire, and installing the 12 gauge blank or optional pepper gas.

  1. Step 1: Attach the Alarm System

    Attach the alarm system in a vertical position to a hard object such as a tree, pole, or frame. You can use the provided mounting holes with eye screws, nails, or screws, or utilize the zip-tie notches with zip ties for secure fastening.

  2. Step 2: Install Pin and Set Trip Wire

    Once the device is securely mounted, install the trigger pin. Connect a trip wire (not included) to the trigger pin and extend it across the area you wish to protect. Ensure the trip wire is taut and positioned at a height that will be triggered by an intruder but is not easily visible.

  3. Step 3: Install 12 Gauge Blank or Optional Pepper Gas

    Carefully insert a 12 gauge blank cartridge or an optional pepper gas cartridge (not included) into the breech of the device. Always ensure the device is pointed in a safe direction and that you are clear of the firing path.

    Important Safety Note: Always remove the 12 gauge blank or optional pepper gas cartridge before disarming or moving the device to prevent accidental discharge.

ఆపరేషన్

The Energetic 12 Gauge Trip Wire Perimeter Alarm is designed for simple, effective operation:

Reloading the Device

After activation, the device can be reloaded and reused:

  1. Ensure the area is safe and the device is disarmed (no cartridge inserted).
  2. Remove any spent cartridge from the breech.
  3. Reinsert the trigger pin into its position.
  4. Insert a new 12 gauge blank or pepper gas cartridge into the breech.
  5. Re-attach or adjust the trip wire as needed.

నిర్వహణ

To ensure the longevity and reliable performance of your Energetic 12 Gauge Trip Wire Perimeter Alarm, follow these maintenance guidelines:

ట్రబుల్షూటింగ్

If you encounter issues with your perimeter alarm, consider the following common solutions:

సమస్యసాధ్యమైన కారణంపరిష్కారం
Alarm does not sound when trip wire is pulled.
  • No 12 gauge blank/cartridge loaded.
  • Cartridge is faulty or expired.
  • Trigger pin not fully engaged or stuck.
  • Internal mechanism obstructed.
  • Ensure a fresh 12 gauge blank or pepper gas cartridge is properly loaded.
  • Replace with a new, reliable cartridge.
  • Check that the trigger pin moves freely and is fully inserted. Clean if necessary.
  • Inspect the breech and firing pin area for debris and clear any obstructions.
Alarm sounds accidentally.
  • Trip wire too sensitive or improperly set.
  • Environmental factors (wind, animals).
  • Device not securely mounted.
  • Adjust trip wire tension or placement.
  • Consider a less sensitive location or higher trip wire placement if small animals are an issue.
  • Ensure the device is firmly attached to a stable object.
Difficulty inserting/removing cartridge.
  • Breech is dirty or corroded.
  • Cartridge is not the correct size or is damaged.
  • Clean the breech thoroughly.
  • Ensure you are using standard 12 gauge blank cartridges or compatible pepper gas cartridges.

స్పెసిఫికేషన్లు

ఫీచర్వివరాలు
ఉత్పత్తి కొలతలు10 x 8 x 4 సెం.మీ (సుమారు 3.94 x 3.15 x 1.57 అంగుళాలు)
మెటీరియల్High-quality 6061 Aluminum Alloy (Rust-proof)
రంగునలుపు
అలారం రకంAcoustic (requires 12 gauge blank or pepper gas cartridge)
యాక్టివేషన్Trip wire activated, spring-loaded firing mechanism
పునర్వినియోగంReloadable and reusable
ఉద్దేశించిన ఉపయోగంOutdoor perimeter security, early warning system
Reference size and warning for Energetic 12 Gauge Trip Wire Perimeter Alarm

Image: Diagram showing the approximate dimensions of the alarm device (3.62 inches tall, 1.14 inches wide) and illustrating that it is not intended for harming animals or people.

ముఖ్యమైన భద్రతా హెచ్చరికలు

సంబంధిత పత్రాలు - B0C7TFN1NP

ముందుగాview ఎనర్జిటిక్ సూపర్ వాల్యూ A67 YKA67C2 LED బల్బ్ - స్పెసిఫికేషన్లు మరియు డేటాషీట్
ఎనర్జిటిక్ సప్‌వాల్యూ A67 YKA67C2 LED బల్బ్ కోసం వివరణాత్మక డేటాషీట్, స్పెసిఫికేషన్లు, అప్లికేషన్ వివరాలు మరియు వివిధ మోడళ్లతో కూడిన సమగ్ర ఉత్పత్తి పట్టికను కలిగి ఉంది.
ముందుగాview Energetic DALI Dimmable Driver ECD37WCC 0500-0950 DL2: Technical Specifications & Installation
Comprehensive technical specifications, features, installation guide, and performance data for the Energetic DALI Dimmable Driver (Model ECD37WCC 0500-0950 DL2). Discover its DALI 2.0 compatibility, touch dim functionality, and multi-wattagఇ ఎంపిక.
ముందుగాview SICK G10 Photoelectric Sensors: Product Family Overview
పైగా సమగ్రమైనదిview of the SICK G10 product family, detailing features, benefits, technical specifications, and ordering information for these powerful and versatile photoelectric sensors.
ముందుగాview ఎనర్జిటిక్ లైటింగ్ FMS సిరీస్ ఫ్లష్‌మౌంట్ ఫిక్చర్ ఇన్‌స్టాలేషన్ మరియు సేఫ్టీ గైడ్
భద్రతా సమాచారం, CCT ఎంపిక, ఇన్‌స్టాలేషన్ దశలు, ట్రబుల్షూటింగ్ మరియు వారంటీ వివరాలతో సహా ఎనర్జిటిక్ లైటింగ్ FMS సిరీస్ ఫ్లష్‌మౌంట్ ఫిక్చర్‌ను ఇన్‌స్టాల్ చేయడం మరియు నిర్వహించడం కోసం సమగ్ర గైడ్.
ముందుగాview ఎనర్జెటిక్ వానిటీ లైటింగ్ ఫిక్స్చర్స్ ఇన్‌స్టాలేషన్ సూచనలు
భద్రతా సమాచారం, ప్యాకేజీ విషయాలు, హార్డ్‌వేర్ వివరాలు మరియు వారంటీతో సహా ENERGETIC MLV231-L100K9027 వానిటీ లైటింగ్ ఫిక్చర్‌ల కోసం దశల వారీ ఇన్‌స్టాలేషన్ గైడ్.
ముందుగాview ఎనర్జిటిక్ లైటింగ్ LED స్ట్రిప్ లైట్ E6SLB సిరీస్ ఇన్‌స్టాలేషన్ గైడ్
ఎనర్జిటిక్ లైటింగ్ E6SLB సిరీస్ LED స్ట్రిప్ లైట్ కోసం సమగ్ర ఇన్‌స్టాలేషన్ సూచనలు, భద్రత, మౌంటు, వైరింగ్ మరియు ట్రబుల్షూటింగ్‌ను కవర్ చేస్తాయి.