Tecmojo 19 Outlets/12A/USB+Overloading Protection

Tecmojo 1U Rack Mount 19 Outlet PDU Power Distribution Unit Instruction Manual

Model: 19 Outlets/12A/USB+Overloading Protection

1. పరిచయం

Thank you for choosing the Tecmojo 1U Rack Mount 19 Outlet PDU Power Distribution Unit. This manual provides essential information for the safe and efficient installation, operation, and maintenance of your new PDU. Please read this manual thoroughly before use and retain it for future reference.

2. ఉత్పత్తి ముగిసిందిview

The Tecmojo 1U Rack Mount PDU is designed for efficient power distribution in standard 19-inch AV, network, and server cabinets. It offers a robust solution for managing power to multiple devices with built-in safety features.

ముఖ్య లక్షణాలు:

  • Versatile and Space-Saving: Compact 1U design for efficient use of space in 19-inch racks.
  • Ample Connectivity: 16 rear-facing plug outlets and 3 front-facing outlets for diverse device connections.
  • Efficient USB Power: Four front-facing USB ports for simultaneous charging of compatible devices.
  • అంతర్నిర్మిత సర్క్యూట్ బ్రేకర్: 12-amp circuit breaker protects against circuit overloads, ensuring reliable performance and equipment safety.
  • హెవీ డ్యూటీ నిర్మాణం: Sturdy metal housing and durable components for long-lasting use.
  • సౌకర్యవంతమైన మౌంటు: Includes mounting ears for easy installation in standard 19-inch racks.

Components and Dimensions:

Tecmojo 1U Rack Mount PDU with dimensions
Figure 1: Tecmojo 1U Rack Mount PDU with key dimensions. The unit measures approximately 19 inches in length, 5 inches in depth, and 1.75 inches in height.
Tecmojo 1U Rack Mount PDU Front Panel Features
Figure 2: Front panel of the Tecmojo PDU, highlighting the 3 front AC outlets, 4 USB charging ports, and the illuminated ON/OFF power switch.
Tecmojo 1U Rack Mount PDU Rear Panel Features
Figure 3: Rear panel of the Tecmojo PDU, showing the 16 rear AC outlets with wired power cables, the integrated 6ft master power cord, and the resettable 15 Amp thermal circuit breaker for overloading protection.
Tecmojo 1U Rack Mount PDU Key Features Overview
చిత్రం 4: ఒక ఓవర్view of the Tecmojo PDU's key features, including 1U rack mountable design, illuminated on/off switch, 4 USB ports, 3 front and 16 rear AC outlets, overloading protection, cold roller steel housing, integrated 6ft master power cord, and UL certification.
Tecmojo 1U Rack Mount PDU installed in a server cabinet
Figure 5: The Tecmojo 1U Rack Mount PDU installed within a server cabinet, demonstrating its integration with other network equipment and cable management.

3. సెటప్

3.1 ర్యాక్ మౌంటు

  1. Ensure your 19-inch rack has available 1U space.
  2. Attach the included mounting ears to the sides of the PDU using the provided screws.
  3. Align the PDU with the rack rails and secure it using appropriate rack screws.

3.2 పవర్ కనెక్షన్

  1. Connect the integrated 6-foot master power cord from the PDU to a grounded 125V AC power source.
  2. Ensure the power source is capable of handling the PDU's maximum load (12A).

3.3 పరికర కనెక్షన్

  1. Plug your devices into the available 16 rear-facing and 3 front-facing AC outlets.
  2. For USB-powered devices, use the four front-facing USB ports.
  3. Distribute the load evenly across the outlets to prevent overloading.

4. ఆపరేటింగ్ సూచనలు

4.1 పవర్ చేయడం ఆన్/ఆఫ్

The PDU features an illuminated ON/OFF switch on the front panel. Press the switch to the 'ON' position to supply power to all connected outlets. Press it to the 'OFF' position to cut power.

4.2 ఓవర్‌లోడ్ రక్షణ

The PDU is equipped with a 12-amp circuit breaker. If the total current draw from connected devices exceeds 12 amps, the circuit breaker will trip to protect the PDU and connected equipment from damage. To reset the breaker, disconnect some devices to reduce the load, then press the reset button on the rear panel.

4.3 USB ఛార్జింగ్

The four front USB ports provide power for charging compatible devices. Simply connect your device's USB cable to an available port.

5. నిర్వహణ

  • Regularly inspect the PDU and its power cord for any signs of damage.
  • Keep the PDU clean and free from dust and debris to ensure proper ventilation.
  • Do not attempt to open or service the PDU yourself. Refer to qualified personnel for repairs.

6. ట్రబుల్షూటింగ్

  • అవుట్‌లెట్‌లకు విద్యుత్ లేదు: Check if the main power switch is ON. Verify the PDU's power cord is securely plugged into a live outlet. Check if the circuit breaker has tripped (see Overload Protection section).
  • USB పోర్ట్‌లు ఛార్జ్ చేయబడవు: Ensure the PDU is powered on. Check the USB cable and the device being charged.
  • అంతరాయ శక్తి: Ensure all connections are secure. Avoid overloading the PDU.

7. స్పెసిఫికేషన్లు

స్పెసిఫికేషన్విలువ
ఉత్పత్తి కొలతలు5 x 19 x 1.7 అంగుళాలు
వస్తువు బరువు9.48 పౌండ్లు
బ్రాండ్టెక్మోజో
రంగునలుపు
మొత్తం పవర్ అవుట్‌లెట్‌లు19 (16 Rear, 3 Front)
USB పోర్ట్‌లు4 (ముందు)
వాల్యూమ్tage125V AC
ప్రస్తుత రేటింగ్12A UL Certified
ప్రత్యేక ఫీచర్ఓవర్‌లోడింగ్ రక్షణ
తయారీదారుటెక్మోజో
ASINB0CJCVB5MX

8. అధికారిక ఉత్పత్తి వీడియోలు

Tecmojo Rack Mount Power Strip Overview

ఈ వీడియో సాధారణ వివరణను అందిస్తుందిview of the Tecmojo Rack Mount Power Strip, showcasing its features and design. It highlights the product's functionality and appearance.

Tecmojo 1U Rack Mount 19 Outlet PDU Power Demonstration

This video demonstrates the Tecmojo 1U Rack Mount 19 Outlet PDU in action, illustrating its use and features within a rack setup. It provides a visual guide to its operation.

9. వారంటీ మరియు మద్దతు

For warranty information and customer support, please refer to the official Tecmojo webమీ రిటైలర్‌ను సైట్‌లో సంప్రదించండి లేదా సంప్రదించండి. వారంటీ క్లెయిమ్‌ల కోసం మీ కొనుగోలు రసీదును ఉంచండి.

సంబంధిత పత్రాలు - 19 Outlets/12A/USB+Overloading Protection

ముందుగాview టెక్మోజో 1U ర్యాక్ మౌంట్ ఆడియో పవర్ డిస్ట్రిబ్యూషన్ యూనిట్ ఇన్‌స్ట్రక్షన్ మాన్యువల్
టెక్మోజో 1U ర్యాక్ మౌంట్ ఆడియో పవర్ డిస్ట్రిబ్యూషన్ యూనిట్ (మోడల్ 13110901) కోసం సూచనల మాన్యువల్. IT పరికరాల గదుల కోసం స్పెసిఫికేషన్లు, భద్రతా హెచ్చరికలు, వారంటీ సమాచారం మరియు మౌంటు సూచనలు ఉన్నాయి.
ముందుగాview టెక్మోజో స్వింగ్ గేట్ వాల్-మౌంట్ ర్యాక్ ఇన్‌స్ట్రక్షన్ మాన్యువల్
టెక్మోజో స్వింగ్ గేట్ వాల్-మౌంట్ ర్యాక్ కోసం సమగ్ర సూచన మాన్యువల్, స్పెసిఫికేషన్లు, హార్డ్‌వేర్, ఉపకరణాలు మరియు పరికరాలను సురక్షితంగా అమర్చడానికి దశల వారీ ఇన్‌స్టాలేషన్ వివరాలను అందిస్తుంది.
ముందుగాview Tecmojo 1U Rack Mount Cooling Unit with 2 Fans - Instruction Manual
Instruction manual for the Tecmojo 1U Rack Mount Cooling Unit with 2 fans. Includes specifications, safety warnings, and installation guidance for IT and network rack environments.
ముందుగాview సర్వర్లు మరియు AV గేర్ కోసం టెక్మోజో ఓపెన్ ఫ్రేమ్ ర్యాక్ - ఇన్‌స్ట్రక్షన్ మాన్యువల్
సర్వర్లు మరియు AV గేర్ కోసం టెక్మోజో యొక్క ఓపెన్ ఫ్రేమ్ రాక్‌ల కోసం సమగ్ర సూచన మాన్యువల్. 11120121, 11120122, మరియు 11120123 మోడల్‌ల కోసం స్పెసిఫికేషన్‌లు, భద్రతా మార్గదర్శకాలు మరియు అసెంబ్లీ సూచనలను కలిగి ఉంటుంది.
ముందుగాview టెక్మోజో స్టీల్ 2-పోస్ట్ స్క్వేర్ హోల్ సర్వర్ ర్యాక్ ఇన్‌స్ట్రక్షన్ మాన్యువల్
టెక్మోజో యొక్క 2-పోస్ట్ స్క్వేర్ హోల్ స్టీల్ సర్వర్ రాక్ కోసం ఇన్స్ట్రక్షన్ మాన్యువల్, వివిధ U సామర్థ్యాల కోసం స్పెసిఫికేషన్లు, భాగాలు మరియు అసెంబ్లీ దశలను వివరిస్తుంది.
ముందుగాview టెక్మోజో వాల్ మౌంట్ AV ర్యాక్ ఇన్‌స్ట్రక్షన్ మాన్యువల్
11120101, 11120102, మరియు 11120103 మోడల్‌ల కోసం భద్రత, స్పెసిఫికేషన్‌లు మరియు దశల వారీ అసెంబ్లీని కవర్ చేసే టెక్మోజో వాల్ మౌంట్ AV రాక్‌ల కోసం వివరణాత్మక సూచన మాన్యువల్. హార్డ్‌వేర్ మరియు విడిభాగాల జాబితాలను కలిగి ఉంటుంది.