1. పరిచయం
This user manual provides comprehensive instructions for the Elitech LMG-10 Digital Manifold Gauge, LMC-100A+ Refrigerant Scale, and ILD-200 Infrared Leak Detector. This integrated system is designed for HVAC professionals to accurately measure pressure, temperature, refrigerant weight, and detect refrigerant leaks in HVAC/R systems. Please read this manual thoroughly before operation to ensure proper use and safety.

Figure 1: Complete Elitech LMG-10 Digital Manifold Gauge System including the manifold, refrigerant scale, leak detector, and hoses.
2. భద్రతా సమాచారం
పరికరానికి గాయం లేదా నష్టం జరగకుండా ఉండటానికి ఎల్లప్పుడూ క్రింది భద్రతా జాగ్రత్తలను గమనించండి:
- Wear appropriate personal protective equipment (PPE), including safety glasses and gloves, when handling refrigerants.
- రిఫ్రిజిరేటర్లతో పనిచేసేటప్పుడు సరైన వెంటిలేషన్ ఉండేలా చూసుకోండి.
- Do not expose the devices to extreme temperatures, humidity, or corrosive environments.
- Do not attempt to disassemble or modify the equipment. Refer all servicing to qualified personnel.
- Verify that all connections are secure before applying pressure or vacuum.
- Use only the specified power sources and accessories.
- Keep the equipment away from children and unauthorized personnel.
3. ప్యాకేజీ విషయాలు
ప్యాకేజీలో అన్ని అంశాలు ఉన్నాయని నిర్ధారించుకోండి:
- Elitech LMG-10 Digital Manifold Gauge
- Elitech LMC-100A+ Refrigerant Scale
- Elitech ILD-200 Infrared Leak Detector
- Charging Hoses (Red, Yellow, Blue)
- ఉష్ణోగ్రత Clampలు (2)
- వినియోగదారు మాన్యువల్ (ఈ పత్రం)
- Carrying Case (for LMG-10 and accessories)

Figure 2: Elitech LMG-10 Digital Manifold Gauge, temperature clamps, and protective carrying case.
4. ఉత్పత్తి ముగిసిందిview
4.1 Elitech LMG-10 Digital Manifold Gauge
The LMG-10 is a robust digital manifold gauge designed for precise pressure and temperature measurements in HVAC/R systems. It supports 88 types of refrigerants and automatically calculates superheat and subcooling.
- ప్రదర్శన: Large LCD for clear readings.
- శీతలీకరణ మద్దతు: Pre-programmed with 88 common refrigerants.
- యూనిట్లు: Supports psi, kg/cm², kPa, MPa, bar for pressure; °F/°C for temperature.
- ఫీచర్లు: Temperature compensation, auto-off function.

Figure 3: Key features of the Elitech LMG-10 Digital Manifold Gauge, highlighting its capabilities.
4.2 Elitech LMC-100A+ Refrigerant Scale
The LMC-100A+ is a high-capacity refrigerant charging scale, essential for accurate refrigerant charging and recovery. It offers high precision and multiple unit options.
- సామర్థ్యం: Up to 220 lbs (100 kg).
- ఖచ్చితత్వం: ±0.05% readings +10g.
- యూనిట్లు: Kg, Lb, Oz.
- ఫీచర్లు: Long battery life (up to 40 hours), auto shut-off after 10 minutes of inactivity.

Figure 4: The Elitech LMC-100A+ Refrigerant Scale, emphasizing its extended battery life and automatic power-saving function.

Figure 5: The Elitech LMC-100A+ Refrigerant Scale actively measuring refrigerant weight, showing a clear digital display.
4.3 Elitech ILD-200 Infrared Leak Detector
The ILD-200 is an advanced infrared refrigerant leak detector offering superior sensitivity and faster response times compared to traditional heated diode detectors.
- గుర్తించే విధానం: Infrared sensor technology.
- సున్నితత్వం: Max 0.1 oz/yr.
- ప్రతిస్పందన సమయం: Immediate.
- ప్రమాణాలు: Meets EN14624, SAE-162, SAE-2791, and SAE-2913 standards.
- ప్రదర్శన: 2.8" large screen with peak display.

Figure 6: Elitech ILD-200 Infrared Leak Detector, detailing its physical dimensions and key technical specifications.

Figure 7: Close-up of the Elitech ILD-200's large display, showing its sensitivity indicator and peak leak detection feature.
4.4 Charging Hoses
The included charging hoses are designed for high-pressure refrigerant applications, ensuring safe and efficient transfer.
- పని ఒత్తిడి: 800 PSI.
- పేలుడు ఒత్తిడి: 4000 PSI.
- రంగులు: Red, Yellow, Blue for easy identification of high-side, low-side, and service ports.

Figure 8: The set of red, yellow, and blue charging hoses, indicating their working and burst pressure capabilities.
5. సెటప్
5.1 Initial Setup of LMG-10 Digital Manifold Gauge
- బ్యాటరీ ఇన్స్టాలేషన్: Open the battery compartment on the back of the LMG-10 and insert the required batteries (refer to specifications for type).
- పవర్ ఆన్: పరికరాన్ని ఆన్ చేయడానికి పవర్ బటన్ను నొక్కండి.
- యూనిట్ ఎంపిక: Use the "MODE" button to cycle through pressure and temperature units. Use the arrow buttons to select desired units (e.g., psi, °F).
- రిఫ్రిజెరాంట్ ఎంపిక: Press the refrigerant selection button (if available, or cycle through modes) to choose the appropriate refrigerant type for your system.
- Zeroing Pressure: With all hoses disconnected and valves closed, press the "ZERO" button to zero the pressure readings.
5.2 Initial Setup of LMC-100A+ Refrigerant Scale
- బ్యాటరీ ఇన్స్టాలేషన్: Install batteries into the scale's remote display unit.
- ప్లేస్మెంట్: ఫ్లాట్, స్థిరమైన ఉపరితలంపై స్కేల్ ఉంచండి.
- పవర్ ఆన్: Press the "POWER" button on the remote display.
- యూనిట్ ఎంపిక: Press the "UNIT" button to select the desired weight unit (Kg, Lb, or Oz).
- Zeroing Scale: Ensure nothing is on the scale platform, then press the "Z/T" (Zero/Tare) button to zero the reading.
5.3 Initial Setup of ILD-200 Infrared Leak Detector
- బ్యాటరీ ఇన్స్టాలేషన్: Open the battery compartment and insert the specified battery (e.g., 3.7V 3000mAh).
- పవర్ ఆన్: Press and hold the power button until the device turns on. Allow a brief warm-up period.
- సున్నితత్వ సర్దుబాటు: Use the "SENS" button to cycle through sensitivity levels (e.g., H for High, M for Medium, L for Low) based on the expected leak size.
6. ఆపరేటింగ్ సూచనలు
6.1 Using the LMG-10 Digital Manifold Gauge
- గొట్టాలను కనెక్ట్ చేయండి:
- Connect the blue hose to the low-side service port of the HVAC system and the blue port on the LMG-10.
- Connect the red hose to the high-side service port of the HVAC system and the red port on the LMG-10.
- Connect the yellow (service) hose to the center port of the LMG-10. This hose will be used for vacuum pump or refrigerant tank connections.
- Attach Temperature Clamps: Securely attach the temperature clamps to the suction line (low-side) and liquid line (high-side) of the system to measure pipe temperatures for superheat/subcooling calculations.
- రీడింగ్లు: Once connected, the LMG-10 will display real-time pressure and temperature readings. Superheat and subcooling values will be calculated automatically based on the selected refrigerant.
- వాక్యూమింగ్:
- Connect the yellow hose to a vacuum pump.
- Open both high and low-side valves on the LMG-10.
- Start the vacuum pump and monitor the vacuum reading on the LMG-10.
- Once the desired vacuum level is reached, close both valves on the LMG-10 and turn off the vacuum pump.
- Charging/Recovery:
- Connect the yellow hose to the refrigerant tank (for charging) or recovery machine (for recovery).
- Use the LMC-100A+ scale to monitor the refrigerant weight.
- Open the appropriate valve(s) on the LMG-10 to allow refrigerant flow.
- Monitor pressure and temperature readings during the process.
6.2 Using the LMC-100A+ Refrigerant Scale
- ట్యాంక్ ఉంచండి: Place the refrigerant tank securely on the center of the scale platform.
- టారే బరువు: Press the "Z/T" button to tare the weight of the tank, setting the display to zero. This allows you to measure only the amount of refrigerant added or removed.
- మానిటర్ బరువు: As refrigerant is charged or recovered, the display will show the net change in weight.
- హోల్డ్ ఫంక్షన్: Some models may have a "HOLD" button to freeze the current reading.
6.3 Using the ILD-200 Infrared Leak Detector
- Power On and Warm-up: Turn on the ILD-200 and allow it to warm up as indicated by the device (usually a few seconds).
- సున్నితత్వాన్ని ఎంచుకోండి: Choose the appropriate sensitivity (H, M, L) based on the suspected leak size and environment. Start with high sensitivity for general scanning.
- స్కాన్ ప్రాంతం: Slowly move the probe tip around suspected leak points (e.g., fittings, valves, coils) at a rate of approximately 1-2 inches per second.
- Detecting Leaks: When a leak is detected, the device will emit an audible alarm and/or visual indication (e.g., LED bar graph, display reading). The alarm frequency or intensity typically increases with the concentration of refrigerant.
- Pinpointing Leaks: Once a leak is indicated, move the probe away and then slowly approach the area again to pinpoint the exact source. Reduce sensitivity if the alarm is constant and overwhelming.
- రీసెట్ ఫంక్షన్: Use the "RESET" button to clear the current reading and re-zero the sensor in a clean air environment.
- మ్యూట్ ఫంక్షన్: Use the "MUTE" button to silence the audible alarm if desired.
7. నిర్వహణ
7.1 సాధారణ సంరక్షణ
- Keep all components clean and free from dirt, dust, and moisture.
- ఉపరితలాలను మృదువైన, డితో తుడవండిamp గుడ్డ. రాపిడి క్లీనర్లు లేదా ద్రావకాలు ఉపయోగించవద్దు.
- Store the equipment in its protective carrying case when not in use.
7.2 బ్యాటరీ భర్తీ
- LMG-10: Replace batteries when the low battery indicator appears on the display. Refer to the battery compartment for specific battery type (e.g., AA, AAA).
- LMC-100A+: Replace batteries in the remote display unit when the battery indicator is low.
- ILD-200: Replace the internal rechargeable battery or standard batteries as needed. Ensure proper polarity.
7.3 Sensor Maintenance (ILD-200)
The infrared sensor in the ILD-200 is generally maintenance-free. However, avoid exposing the sensor tip to excessive dirt or oil. If performance degrades, contact Elitech support.
8. ట్రబుల్షూటింగ్
| సమస్య | సాధ్యమైన కారణం | పరిష్కారం |
|---|---|---|
| LMG-10 does not power on. | డెడ్ లేదా తప్పుగా ఇన్స్టాల్ చేయబడిన బ్యాటరీలు. | బ్యాటరీ ధ్రువణతను తనిఖీ చేయండి; బ్యాటరీలను భర్తీ చేయండి. |
| Inaccurate pressure readings on LMG-10. | Gauge not zeroed; sensor contamination; faulty connection. | Zero the gauge before use; ensure clean connections; check for leaks in hoses. |
| LMC-100A+ scale shows "Err" or unstable readings. | Uneven surface; overloaded; battery low; interference. | Place on a flat, stable surface; ensure weight is within capacity; replace batteries; move away from strong electromagnetic fields. |
| ILD-200 constantly alarms or gives false positives. | High background refrigerant concentration; sensor contaminated; sensitivity too high. | Move to a clean air environment and reset; clean probe tip; reduce sensitivity. |
| ILD-200 does not detect leaks. | Low sensitivity; sensor failure; battery low. | Increase sensitivity; replace battery; contact support if sensor is suspected faulty. |
9. స్పెసిఫికేషన్లు
| భాగం | స్పెసిఫికేషన్ | విలువ |
|---|---|---|
| LMG-10 Digital Manifold Gauge | మద్దతు ఉన్న రిఫ్రిజెరాంట్లు | 88 రకాలు |
| ఒత్తిడి యూనిట్లు | psi, kg/cm², kPa, MPa, bar | |
| ఉష్ణోగ్రత యూనిట్లు | °F/°C | |
| బ్యాటరీ లైఫ్ | 200 గంటల వరకు | |
| ఫీచర్లు | Superheat/Subcooling auto-calc, Temp Compensation, Auto-off | |
| LMC-100A+ Refrigerant Scale | కెపాసిటీ | 220 పౌండ్లు (100 కిలోలు) |
| ఖచ్చితత్వం | ±0.05% readings +10g | |
| బరువు యూనిట్లు | Kg, Lb, Oz | |
| బ్యాటరీ లైఫ్ | 40 గంటల వరకు | |
| ILD-200 Infrared Leak Detector | గరిష్ట సున్నితత్వం | 0.1 oz/yr |
| ప్రతిస్పందన సమయం | వెంటనే | |
| బ్యాటరీ | 3.7V 3000mAh | |
| ప్రమాణాలు మెట్ | EN14624, SAE-162, SAE-2791, SAE-2913 | |
| ప్రదర్శించు | 2.8" Large Screen Peak Display | |
| ఛార్జింగ్ గొట్టాలు | పని ఒత్తిడి | 800 PSI |
| పేలుడు ఒత్తిడి | 4000 PSI | |
| General Product Dimensions | ఉత్పత్తి కొలతలు | 11 x 8 x 14 అంగుళాలు |
| వస్తువు బరువు | 1.1 పౌండ్లు | |
| మెటీరియల్ | Nylon, Polypropylene, Rubber |
10. వారంటీ మరియు మద్దతు
Elitech provides dedicated customer service and technical support for its products. For any inquiries, technical assistance, or warranty claims, please contact Elitech's local team.
- కస్టమర్ సేవ: 24/7 అందుబాటులో ఉంటుంది.
- సాంకేతిక మద్దతు: Available for product operation and troubleshooting.
- వారంటీ సమాచారం: Refer to the product packaging or Elitech's official webవివరణాత్మక వారంటీ నిబంధనలు మరియు షరతుల కోసం సైట్.
- సంప్రదింపు సమాచారం: అధికారిక ఎలిటెక్ను సందర్శించండి website or refer to the contact details provided with your product for the most up-to-date support channels.