This manual provides essential information for the safe and efficient operation, installation, and maintenance of the Nuaire NU-5500 DH AutoFlow CO2 Air-Jacketed Incubator, Series 11. Please read this manual thoroughly before operating the incubator to ensure proper usage and to prevent damage or injury.

The Nuaire NU-5500 is designed to provide a stable and controlled environment for cell culture applications, maintaining precise temperature and CO2 levels.

భద్రతా సమాచారం

Always follow standard laboratory safety procedures when operating this equipment. Ensure the incubator is placed on a stable, level surface. Do not block ventilation openings. Refer to local regulations for CO2 cylinder handling and storage.

సెటప్

అన్ప్యాకింగ్ మరియు తనిఖీ

Carefully remove the incubator from its packaging. Inspect for any visible damage that may have occurred during shipping. Report any damage to the carrier immediately.

ముందు view of the Nuaire NU-5500 incubator with an external thermometer on top.

మూర్తి 1: ముందు view of the Nuaire NU-5500 DH AutoFlow CO2 Air-Jacketed Incubator, showing its overall design and an external thermometer unit placed on top.

ప్లేస్‌మెంట్

Place the incubator on a sturdy, level surface capable of supporting its weight. Ensure adequate clearance around the unit for ventilation and maintenance access. Avoid direct sunlight or proximity to heat sources.

ఎలక్ట్రికల్ కనెక్షన్

Connect the incubator to a grounded electrical outlet matching the specifications on the product label. The unit operates on 115 AC, 50/60Hz, 1 phase, 3 Amps.

Product label showing electrical specifications for Nuaire NU-5500 incubator.

Figure 2: Product label indicating the model number (NU-5500), series (11), serial number, year of manufacture (2004), and electrical rating (115 AC, 50/60Hz, 1 phase, 3 Ampలు).

CO2 Gas Connection

Connect the CO2 gas supply line to the appropriate inlet on the incubator. Ensure all connections are secure and leak-free. Use a medical or laboratory grade CO2 cylinder with a suitable pressure regulator.

ఆపరేటింగ్ సూచనలు

Power On and Initial Warm-up

After connecting power and CO2, turn on the incubator. Allow the unit to stabilize for at least 24 hours before introducing cultures. The display will show current temperature and CO2 percentage.

Close-up of the Nuaire NU-5500 control panel showing temperature and CO2 percentagఇ డిస్ప్లేలు.

మూర్తి 3: వివరంగా view of the control panel, displaying the current temperature (37.2°C) and CO2 percentage (0.0%).

Setting Temperature and CO2 Levels

ఉపయోగించండి SEL బటన్ మరియు బాణం కీలు (▲ ▲ తెలుగు, ) on the control panel to navigate and adjust setpoints for temperature and CO2 concentration. Refer to the specific protocol for your cell culture requirements.

Nuaire NU-5500 control panel with temperature and CO2 displays, and indicator lights.

Figure 4: The control panel showing the temperature and CO2 displays, along with indicator lights for "HEAT JACKET", "INJECT CO2", "DOOR AJAR", "AIR CLASS ISO 5", "CO2 TANK 1", and "CO2 TANK 2". The "RUN SETUP" and "ALARM" indicators are also visible.

లోడ్ అవుతోంది Sampలెస్

Open the incubator door and place culture vessels on the shelves. Minimize door open time to maintain stable internal conditions. The interior features multiple shelves for sampలే ప్లేస్మెంట్.

ఇంటీరియర్ view of the Nuaire NU-5500 incubator with the door open, showing shelves and stainless steel interior.

మూర్తి 5: ఇంటీరియర్ view of the incubator with the door open, revealing the stainless steel chamber and removable shelves designed for culture vessels.

నిర్వహణ

ఇంటీరియర్ క్లీనింగ్

Regularly clean the interior chamber with a mild, non-corrosive disinfectant. Ensure all surfaces are dry before closing the door. Remove shelves for thorough cleaning.

HEPA ఫిల్టర్ నిర్వహణ

The incubator is equipped with a HEPA filtration system. Check filters periodically as indicated on the unit. Replace filters according to manufacturer guidelines or when the indicator suggests.

Close-up of the Nuaire NU-5500 HEPA filter system label.

Figure 6: Label indicating "HEPA FILTRATION SYSTEM" and "CHECK FILTERS PERIODICALLY", highlighting the importance of filter maintenance for maintaining air quality within the incubator.

Water Pan Refill

Ensure the water pan at the bottom of the chamber is filled with sterile distilled water to maintain humidity. Check water levels regularly and refill as needed.

ట్రబుల్షూటింగ్

సమస్యసాధ్యమైన కారణంపరిష్కారం
ఉష్ణోగ్రత హెచ్చుతగ్గులుDoor not sealed properly, ambient temperature changes, heater malfunction.Check door seal, ensure stable room temperature, contact service if heater issue suspected.
CO2 Level UnstableCO2 tank empty, gas line leak, sensor malfunction.Replace CO2 tank, check all gas connections, calibrate or replace CO2 sensor.
అలారం సూచిక ఆన్ చేయబడిందిOut-of-range temperature/CO2, door ajar.Check setpoints, ensure door is fully closed, refer to specific alarm codes if available.

స్పెసిఫికేషన్లు

వారంటీ మరియు మద్దతు

For warranty information and technical support, please refer to the original purchase documentation or contact the vendor. This manual covers the operational aspects of the Nuaire NU-5500 DH AutoFlow CO2 Air-Jacketed Incubator, Series 11.

For parts and service inquiries, please provide the model number (NU-5500) and serial number (e.g., 94249102504 from the product label) of your unit.

సంబంధిత పత్రాలు - NU-5500

ముందుగాview 10 Essential Maintenance Tips for NuAire Water-Jacketed CO2 Incubators
A comprehensive guide detailing 10 essential preventive maintenance tips for NuAire Water-Jacketed CO2 Incubators to ensure optimal growth conditions and prevent contamination. Covers cleaning, gas supply, filters, seals, sensors, and condensation.
ముందుగాview NuAire అల్ట్రా తక్కువ ఉష్ణోగ్రత ఫ్రీజర్ యూజర్ మాన్యువల్
NU-99338JE మరియు ఇతర మోడళ్లతో సహా NuAire అల్ట్రా లో టెంపరేచర్ ఫ్రీజర్‌ల కోసం సమగ్ర సూచనలు, భద్రతా మార్గదర్శకాలు, స్పెసిఫికేషన్‌లు మరియు ట్రబుల్షూటింగ్‌ను అందించే వినియోగదారు మాన్యువల్.
ముందుగాview NUWIND 2.0 Centrifuge Operation and Maintenance Manual
Comprehensive operation and maintenance manual for the NuAire NUWIND 2.0 series laboratory centrifuges, including models NU-C200V, NU-C200R, NU-C200V-E, and NU-C200R-E. Covers installation, operation, safety, troubleshooting, and specifications.
ముందుగాview Nuaire DRI-ECO-CO2 ఇన్‌స్టాలేషన్ మాన్యువల్
RF ఎనేబుల్డ్ హాల్ కంట్రోల్ DRI-ECO యూనిట్లతో ఉపయోగం కోసం రూపొందించబడిన Nuaire DRI-ECO-CO2 CO2 సెన్సార్ కోసం ఇన్‌స్టాలేషన్ మాన్యువల్. భద్రతా సమాచారం, ఇన్‌స్టాలేషన్, వైరింగ్, నియంత్రణలు, నిర్వహణ, వారంటీ మరియు జీవితాంతం రీసైక్లింగ్‌ను కవర్ చేస్తుంది.
ముందుగాview Nuaire MRXBOX(AB)-ECO3-AE ఇన్‌స్టాలేషన్ మాన్యువల్: హీట్ రికవరీతో మెకానికల్ వెంటిలేషన్
హీట్ రికవరీ (MVHR)తో కూడిన Nuaire MRXBOX(AB)-ECO3-AE మెకానికల్ వెంటిలేషన్ యూనిట్ల కోసం సమగ్ర ఇన్‌స్టాలేషన్ మాన్యువల్. భద్రత, మెకానికల్ మరియు ఎలక్ట్రికల్ ఇన్‌స్టాలేషన్, కమీషనింగ్, నిర్వహణ, వారంటీ మరియు రీసైక్లింగ్‌ను కవర్ చేస్తుంది.
ముందుగాview న్యూయిర్ బెస్పోక్ బాక్సర్ ఎయిర్ హ్యాండ్లింగ్ యూనిట్స్ ఇన్‌స్టాలేషన్ మాన్యువల్
నువైర్ యొక్క బెస్పోక్ బాక్సర్ ఎయిర్ హ్యాండ్లింగ్ యూనిట్ల కోసం సమగ్ర ఇన్‌స్టాలేషన్, ఆపరేషన్ మరియు నిర్వహణ మాన్యువల్. భద్రత, హ్యాండ్లింగ్, మెకానికల్ మరియు ఎలక్ట్రికల్ ఇన్‌స్టాలేషన్, కమీషనింగ్, నిర్వహణ, వారంటీ మరియు జీవితాంతం రీసైక్లింగ్‌ను కవర్ చేస్తుంది.