ACiQ B0DHFF2DKL

ACiQ 2.5 టన్ 17 SEER2 సెంట్రల్ ఇన్వర్టర్ హీట్ పంప్ సిస్టమ్ యూజర్ మాన్యువల్

Model: B0DHFF2DKL

1. పరిచయం

This manual provides essential information for the installation, operation, and maintenance of your ACiQ 2.5 Ton 17 SEER2 Central Inverter Heat Pump System. This system is designed to provide efficient heating and cooling for residential and light commercial applications. Please read this manual thoroughly before attempting any installation or operation to ensure proper function and safety.

2. భద్రతా సమాచారం

Always prioritize safety. Improper installation, adjustment, alteration, service, or maintenance can cause property damage, injury, or death. Consult a qualified installer, service agency, or the gas supplier for information or assistance. The information contained in this manual is intended for use by qualified service personnel only.

  • విద్యుత్ భద్రత: Ensure the power supply is disconnected before performing any service or maintenance. All electrical wiring must comply with local and national electrical codes.
  • శీతలకరణి నిర్వహణ: This system uses R-454B refrigerant. Only certified technicians should handle refrigerants.
  • సంస్థాపన: ఇన్‌స్టాలేషన్ తప్పనిసరిగా లైసెన్స్ పొందిన HVAC ప్రొఫెషనల్ ద్వారా నిర్వహించబడాలి.
  • వ్యక్తిగత రక్షణ పరికరాలు: Always wear appropriate personal protective equipment (PPE) such as gloves and safety glasses during installation and maintenance.

3 కీ ఫీచర్లు

  • ఇన్వర్టర్ టెక్నాలజీ: Provides precise temperature control, reduced energy consumption, and quieter operation.
  • అధిక సామర్థ్యం: 18.8 SEER2 and 9.7 HSPF2 ratings for energy savings.
  • విస్తృత ఆపరేటింగ్ పరిధి: Reliable performance from -13°F to 122°F.
  • నిశ్శబ్ద ఆపరేషన్: Indoor noise levels as low as 44 dBA, outdoor unit at 60 dBA.
  • మన్నికైన భాగాలు: Rotary compressor, aluminum coil, and fiberglass-free insulation.
  • పర్యావరణ అనుకూల శీతలకరణి: Utilizes R-454B refrigerant.
  • ఫ్లెక్సిబుల్ ఇన్‌స్టాలేషన్: Supports horizontal and vertical air handler installation.
  • స్మార్ట్ నియంత్రణలు: Compatible with wired controllers, WiFi, and third-party thermostats.
  • Integrated Back-up Heat: Includes a 10kW back-up heat kit for supplemental heating.

4. భాగాలు ఓవర్view

The ACiQ 2.5 Ton 17 SEER2 Central Inverter Heat Pump System includes the following main components:

  • Outdoor Condensing Unit (Heat Pump)
  • Indoor Air Handler Unit
  • 10kW Back-up Heat Kit
  • 30' Line Set
  • Gauge Electrical Whip
  • 60A Non-Fused Disconnect Switch
  • వైఫై థర్మోస్టాట్
  • సర్జ్ ప్రొటెక్టర్
  • CPS ఛార్జింగ్ అడాప్టర్
  • వాల్ స్లీవ్
ACiQ 2.5 Ton 17 SEER2 Central Inverter Heat Pump System components

మూర్తి 1: పైగాview of the ACiQ 2.5 Ton 17 SEER2 Central Inverter Heat Pump System, showing the outdoor unit, indoor air handler, 10kW back-up heat kit, thermostat, line set, and various installation accessories.

5. సెటప్ మరియు ఇన్‌స్టాలేషన్

Installation of this ACiQ heat pump system requires specialized knowledge and tools. It must be performed by a qualified and licensed HVAC technician to ensure safety, compliance with local codes, and optimal performance. Refer to the detailed installation manual provided with the product for specific instructions.

5.1 ప్రీ-ఇన్‌స్టాలేషన్ తనిఖీలు

  • Verify that the electrical supply matches the unit's requirements (Indoor: 115/208/230V, 60Hz, 1Ph; Outdoor: 208/230V, 60Hz, 1Ph).
  • సరైన గాలి ప్రవాహం మరియు నిర్వహణ యాక్సెస్ కోసం వీలు కల్పిస్తూ, ఇండోర్ మరియు అవుట్‌డోర్ యూనిట్‌లకు తగిన స్థలం ఉండేలా చూసుకోండి.
  • Confirm that the maximum piping length (164 ft / 50m) and height difference (82 ft / 25m) are not exceeded.

5.2 Air Handler Installation

The indoor air handler unit is designed for flexible installation, supporting upflow, downflow, and horizontal configurations to suit various space requirements.

Multi-Positional Air Handler Unit installation options

మూర్తి 2: Diagram illustrating the multi-positional capabilities of the indoor air handler unit, showing options for upflow, downflow, and horizontal installation.

5.3 అవుట్‌డోర్ యూనిట్ ప్లేస్‌మెంట్

Consider the outdoor unit's dimensions and required clearances for optimal performance and maintenance. The unit features a compact design compared to traditional systems.

Outdoor unit size comparison with traditional units

మూర్తి 3: Graphic comparing the smaller footprint of the ACiQ outdoor unit (20 inches clearance) versus a traditional unit (36 inches clearance), highlighting its high efficiency and self-cleaning features.

6. ఆపరేటింగ్ సూచనలు

Your ACiQ heat pump system offers advanced control options for comfortable and efficient operation.

6.1 ప్రాథమిక ఆపరేషన్ మోడ్‌లు

  • శీతలీకరణ మోడ్: Provides cooling with a capacity of 31,000 BTU/hr. Operates efficiently from -13°F to 122°F ambient temperatures.
  • హీటింగ్ మోడ్: Provides heating with a capacity of 30,000 BTU/hr at 47°F. Reliable warmth down to -13°F. The 10kW back-up heat kit provides supplemental heat when needed.
  • అభిమాని మోడ్: వేడి చేయడం లేదా చల్లబరచడం లేకుండా గాలిని ప్రసరింపజేస్తుంది.
  • ఆటో మోడ్: సెట్ ఉష్ణోగ్రతను నిర్వహించడానికి తాపన మరియు శీతలీకరణ మధ్య స్వయంచాలకంగా మారుతుంది.
ACiQ outdoor unit operating in extreme heat

మూర్తి 4: The ACiQ outdoor unit installed on a patio, demonstrating its ability to operate effectively in extreme heat conditions, up to 122°F.

ACiQ outdoor unit operating in extreme cold

మూర్తి 5: The ACiQ outdoor unit partially covered in snow, illustrating its capability to operate in extreme cold temperatures, down to -13°F.

6.2 Smart Controls

The system can be controlled via the included wired thermostat, WiFi-enabled app, or compatible third-party thermostats. The WiFi app allows for remote control and monitoring of your system.

ACiQ Smart Home app and wired thermostat

మూర్తి 6: Image showing the ACiQ Smart Home mobile application interface on a smartphone alongside a wired thermostat, demonstrating the system's smart control capabilities for climate management.

7. నిర్వహణ

Regular maintenance ensures the longevity and efficiency of your ACiQ heat pump system. Always disconnect power before performing any maintenance.

  • ఎయిర్ ఫిల్టర్ భర్తీ: Check and replace air filters in the indoor air handler every 1-3 months, or more frequently if needed. Dirty filters restrict airflow and reduce efficiency.
  • అవుట్‌డోర్ యూనిట్ శుభ్రపరచడం: Keep the outdoor unit free from debris, leaves, and dirt. Periodically clean the coils with a soft brush or water hose (ensure power is off).
  • డ్రైనేజీ వ్యవస్థ: Ensure the condensate drain line is clear and free of blockages to prevent water overflow.
  • వృత్తిపరమైన తనిఖీ: Schedule annual inspections and maintenance by a qualified HVAC technician.

8. ట్రబుల్షూటింగ్

This section provides solutions for common issues. For complex problems, contact a qualified HVAC technician.

  • శక్తి లేదు: Check circuit breakers and ensure the disconnect switch is in the ON position.
  • తగినంత వేడి/చల్లదనం లేకపోవడం: Verify thermostat settings, check air filters for blockage, and ensure outdoor unit is not obstructed.
  • అసాధారణ శబ్దాలు: Minor operational noises are normal. Loud or unusual noises may indicate a problem requiring professional inspection.
  • నీటి లీకేజీలు: Check condensate drain line for blockages.

9. స్పెసిఫికేషన్లు

Dimensions of ACiQ indoor and outdoor units

మూర్తి 7: Image displaying the dimensions of both the indoor air handler unit (49.02" H x 21.02" W x 21.02" D) and the outdoor condensing unit (35.04" H x 37.24" W x 16.14" D).

Cooling capacity chart for ACiQ heat pump

మూర్తి 8: Chart detailing the cooling capacity of the ACiQ system at various outdoor temperatures: 86°F (118% capacity), 95°F (113% capacity), 110°F (99% capacity), and 122°F (48% capacity).

Heating capacity chart for ACiQ heat pump

మూర్తి 9: Chart detailing the heating capacity of the ACiQ system at various outdoor temperatures: -22°F (N/A), -13°F (41% capacity), 0°F (57% capacity), 17°F (70% capacity), and 32°F (73% capacity).

ఫీచర్వివరాలు
శీతలీకరణ సామర్థ్యం31,000 BTU/గం
తాపన సామర్థ్యం30,000 BTU/hr (at 47°F)
SEER2 రేటింగ్18.8
HSPF2 రేటింగ్9.7
శీతలకరణి రకంR-454B
ఇండోర్ యూనిట్ పవర్ సప్లై115/208/230V, 60Hz, 1Ph
Outdoor Unit Power Supply208/230V, 60Hz, 1Ph
గరిష్ట పైపింగ్ పొడవు164 అడుగులు (50 మీ)
Max Height Difference82 అడుగులు (25 మీ)
Indoor Unit Dimensions (W × D × H)21.02" × 21.02" × 49.02"
Outdoor Unit Dimensions (W × D × H)37.24" × 16.14" × 31.89"
ఇండోర్ యూనిట్ నికర బరువు128.97 పౌండ్లు
అవుట్‌డోర్ యూనిట్ నికర బరువు164.02 పౌండ్లు

10. వారంటీ మరియు మద్దతు

ACiQ offers a comprehensive warranty for this heat pump system:

  • విడిభాగాల వారంటీ: 7 సంవత్సరాలు
  • కంప్రెసర్ వారంటీ: 12 సంవత్సరాలు

These warranty terms are valid when the system is installed by a certified technician and registered online with the manufacturer. For technical support, service inquiries, or warranty claims, please refer to the contact information provided in your product packaging or visit the official ACiQ webసైట్.

సంబంధిత పత్రాలు - B0DHFF2DKL

ముందుగాview ACiQ 9K-24K స్టాండర్డ్ హీట్ సింగిల్-జోన్ సిస్టమ్స్: ఇన్‌స్టాలేషన్ & ఓనర్స్ మాన్యువల్
ACiQ 9K-24K స్టాండర్డ్ హీట్ సింగిల్-జోన్ సిస్టమ్స్ ఇన్‌స్టాలేషన్ & ఓనర్స్ మాన్యువల్. ఈ గైడ్ ACiQ ఎయిర్ కండిషనర్‌ల కోసం ఇన్‌స్టాలేషన్, ఆపరేషన్, భద్రత మరియు నిర్వహణను వివరిస్తుంది, వీటిలో మోడల్ ప్రత్యేకతలు మరియు R454B రిఫ్రిజెరాంట్ సమాచారం కూడా ఉంటుంది.
ముందుగాview ACiQ సెంట్రల్ ఇన్వర్టర్ సిస్టమ్స్ ఇన్‌స్టాలేషన్ మాన్యువల్
ACiQ సెంట్రల్ ఇన్వర్టర్ ఎయిర్ కండిషనింగ్ మరియు హీట్ పంప్ సిస్టమ్స్ కోసం సమగ్ర ఇన్‌స్టాలేషన్ మాన్యువల్, భద్రతా జాగ్రత్తలు, రిఫ్రిజెరాంట్ పైపింగ్, అవుట్‌డోర్ యూనిట్ ఇన్‌స్టాలేషన్, వైరింగ్, పవర్ స్పెసిఫికేషన్‌లు, ఎయిర్ ఎవాక్యుయేషన్ మరియు టెస్ట్ రన్ విధానాలను వివరిస్తుంది.
ముందుగాview ACiQ వాల్-మౌంటెడ్ ఎయిర్ హ్యాండ్లర్ & ఎక్స్‌ట్రీమ్ హీట్ సింగిల్-జోన్ కండెన్సర్ ఇన్‌స్టాలేషన్ & ఓనర్స్ మాన్యువల్
ఈ మాన్యువల్ ACiQ వాల్-మౌంటెడ్ ఎయిర్ హ్యాండ్లర్లు మరియు ఎక్స్‌ట్రీమ్ హీట్ సింగిల్-జోన్ కండెన్సర్‌ల కోసం వివరణాత్మక ఇన్‌స్టాలేషన్, ఆపరేషన్ మరియు భద్రతా మార్గదర్శకాలను అందిస్తుంది, ACIQ-06W-HH-MD నుండి ACIQ-24ZPL-HP230C వరకు మోడల్‌లను కవర్ చేస్తుంది.
ముందుగాview ACiQ సెంట్రల్ ఇన్వర్టర్ సిస్టమ్స్ అవుట్‌డోర్ యూనిట్ ఇన్‌స్టాలేషన్ మాన్యువల్
ACiQ సెంట్రల్ ఇన్వర్టర్ సిస్టమ్స్ అవుట్‌డోర్ యూనిట్ల కోసం సమగ్ర ఇన్‌స్టాలేషన్ మాన్యువల్, భద్రతా జాగ్రత్తలు, రిఫ్రిజెరాంట్ పైపింగ్, వైరింగ్, యూనిట్ ఇన్‌స్టాలేషన్ మరియు ACiQ-18-AC, ACiQ-24-AC, ACiQ-18-EHPB మరియు ఇతర మోడళ్ల కోసం పరీక్షా విధానాలను కవర్ చేస్తుంది.
ముందుగాview ACiQ నెక్స్ట్ జనరేషన్ డక్టెడ్ హీట్ పంప్ సిస్టమ్: థర్మోస్టాట్ వైరింగ్ కోసం క్విక్ స్టార్ట్ గైడ్
ఈ గైడ్ థర్మోస్టాట్‌లను ACiQ నెక్స్ట్ జెన్ డక్టెడ్ హీట్ పంప్ సిస్టమ్‌కు కనెక్ట్ చేయడానికి మరియు వైరింగ్ చేయడానికి అవసరమైన సమాచారాన్ని అందిస్తుంది. ఇది వివిధ రకాల థర్మోస్టాట్‌లకు DIP స్విచ్ సెట్టింగ్‌లు మరియు టెర్మినల్ బ్లాక్ కాన్ఫిగరేషన్‌లతో సహా సిఫార్సు చేయబడిన మరియు ప్రత్యామ్నాయ కనెక్షన్ ఎంపికలను వివరిస్తుంది.
ముందుగాview ACiQ ఎసెన్షియల్స్ మినీ-స్ప్లిట్ ఎయిర్ హ్యాండ్లర్ & కండెన్సర్ ఇన్‌స్టాలేషన్ మరియు ఓనర్స్ మాన్యువల్
ACiQ Essentials మినీ-స్ప్లిట్ ఎయిర్ హ్యాండ్లర్ మరియు కండెన్సర్ సిస్టమ్‌ల కోసం సమగ్ర ఇన్‌స్టాలేషన్ మరియు యజమాని మాన్యువల్, భద్రతా జాగ్రత్తలు, భాగాల గుర్తింపు, రిమోట్ కంట్రోల్ ఆపరేషన్, ఇన్‌స్టాలేషన్ విధానాలు, పరీక్ష పరుగులు, నిర్వహణ మరియు వివిధ మోడళ్ల కోసం ట్రబుల్షూటింగ్‌ను కవర్ చేస్తుంది. భద్రతా ప్రోటోకాల్‌లు మరియు నియంత్రణ సమ్మతిని నొక్కిచెప్పే మండే రిఫ్రిజెరాంట్ R454Bని ఉపయోగించే సిస్టమ్‌ల సర్వీసింగ్‌కు సంబంధించిన కీలకమైన సమాచారాన్ని కూడా మాన్యువల్ కలిగి ఉంది. ACiQ మినీ-స్ప్లిట్ హీట్ పంప్ సిస్టమ్‌ల సురక్షితమైన మరియు సమర్థవంతమైన ఆపరేషన్‌ను నిర్ధారించడానికి ఇది ప్రొఫెషనల్ ఇన్‌స్టాలర్‌లు మరియు తుది-వినియోగదారుల కోసం రూపొందించబడింది.