1. పరిచయం
This manual provides detailed instructions for the KAIWEETS HT206D Digital Clamp Meter and the KAIWEETS 0.8V-100V DC Smart Automotive Test Light. These instruments are designed for accurate electrical measurements and automotive circuit testing, suitable for professional and household use. Please read this manual thoroughly before operation to ensure safe and correct usage.

Image 1.1: KAIWEETS HT206D Digital Clamp Meter and KAIWEETS 0.8V-100V DC Smart Automotive Test Light.
This image displays both the KAIWEETS HT206D Digital Clamp Meter (left) and the KAIWEETS 0.8V-100V DC Smart Automotive Test Light (right). The clamp meter is red and black with a digital display and rotary dial. The test light is black with a digital display, probe, and alligator clip.
2. భద్రతా సమాచారం
Always adhere to basic safety precautions when using electrical testing equipment to reduce the risk of fire, electric shock, or personal injury. Keep this manual for future reference.
- ప్రతి ఫంక్షన్ కోసం పేర్కొన్న గరిష్ట ఇన్పుట్ విలువలను మించకూడదు.
- వాల్యూమ్తో పని చేస్తున్నప్పుడు చాలా జాగ్రత్తగా ఉండండిtag30V AC RMS, 42V పీక్ లేదా 60V DC కంటే ఎక్కువ. ఈ వాల్యూమ్లుtagషాక్ ప్రమాదాన్ని కలిగిస్తుంది.
- Before measuring current, ensure the instrument is properly set up and the test leads are correctly connected.
- ఫంక్షన్లు లేదా పరిధులను మార్చడానికి ముందు ఎల్లప్పుడూ సర్క్యూట్ నుండి టెస్ట్ లీడ్లను డిస్కనెక్ట్ చేయండి.
- Inspect the test leads for damaged insulation or exposed metal before use. Replace if damaged.
- Do not operate the instrument if it appears damaged or if it is not functioning properly.
- ఆపరేషన్ ముందు బ్యాటరీ కవర్ సురక్షితంగా మూసివేయబడిందని నిర్ధారించుకోండి.
- Use caution when working in wet environments.
- For current measurement with the clamp meter, clamp around only one wire, not the entire power cord, to obtain an accurate reading.
3. ఉత్పత్తి భాగాలు
3.1 KAIWEETS HT206D Digital Clamp మీటర్

Image 3.1: KAIWEETS HT206D Digital Clamp Meter and included accessories.
This image shows the KAIWEETS HT206D Digital Clamp Meter along with its accessories: two 1.5V AA batteries, red and black test leads, a K-type thermocouple, and a carrying case.
KAIWEETS HT206D డిజిటల్ Clamp Meter includes:
- డిజిటల్ Clamp మీటర్ యూనిట్
- పరీక్ష లీడ్లు (ఎరుపు మరియు నలుపు)
- K-రకం థర్మోకపుల్
- క్యారీయింగ్ కేసు
- వినియోగదారు మాన్యువల్ (ఈ పత్రం)
- Batteries (typically 2x AA or AAA, check packaging for exact type)
3.2 KAIWEETS 0.8V-100V DC Smart Automotive Test Light
The KAIWEETS 0.8V-100V DC Smart Automotive Test Light includes:
- Smart Automotive Test Light unit with coiled cable and alligator clip
- వినియోగదారు మాన్యువల్ (ఈ పత్రం)
4. సెటప్
4.1 KAIWEETS HT206D Digital Clamp Meter Battery Installation
- Locate the battery compartment on the back of the clamp మీటర్.
- బ్యాటరీ కవర్ను తెరవడానికి స్క్రూడ్రైవర్ని ఉపయోగించండి.
- Insert the specified batteries (e.g., 2x AA 1.5V) according to the polarity markings inside the compartment.
- బ్యాటరీ కవర్ను మార్చండి మరియు దానిని స్క్రూతో భద్రపరచండి.
4.2 KAIWEETS 0.8V-100V DC Smart Automotive Test Light
This device is typically powered by the circuit it is testing. No separate battery installation is required for the test light itself.
- Connect the alligator clip to a suitable ground point (e.g., vehicle chassis for automotive applications).
- Ensure the probe tip is clean and free from debris.
5. ఆపరేటింగ్ సూచనలు
5.1 KAIWEETS HT206D Digital Clamp మీటర్
Turn the rotary dial to select the desired measurement function.
5.1.1 AC/DC కరెంట్ కొలత (Clamp)
- Turn the rotary dial to the "600A" or "60A" AC/DC current range.
- cl తెరవండిamp jaws and enclose a single conductor. Ensure the conductor is centered within the jaws.
- డిస్ప్లేలో ప్రస్తుత విలువను చదవండి.
- ముఖ్యమైన: To measure current, the clamp must enclose only one conductor. Clamping around an entire power cord (which contains both live and neutral wires) will result in a zero reading.

Image 5.1.1: KAIWEETS HT206D Digital Clamp Meter measuring current.
This image shows the KAIWEETS HT206D Digital Clamp Meter in use, clamping around a single electrical wire to measure current. The display shows a reading of "270.1 AC".
5.1.2 AC/DC వాల్యూమ్tage, Resistance, Capacitance, Frequency, Diode, Continuity, Temperature Measurement
- ఎరుపు పరీక్ష లీడ్ను "VΩHz" ఇన్పుట్ జాక్కు మరియు నలుపు పరీక్ష లీడ్ను "COM" ఇన్పుట్ జాక్కు కనెక్ట్ చేయండి.
- Turn the rotary dial to the desired function (e.g., V~ for AC Voltage, V- for DC Voltage, Ω for Resistance, etc.).
- For temperature measurement, connect the K-type thermocouple to the appropriate input jacks (usually marked with temperature symbols) and select the temperature function.
- Apply the test leads or thermocouple to the circuit or component under test.
- డిస్ప్లేలో కొలతను చదవండి.

Image 5.1.2: KAIWEETS HT206D Digital Clamp Meter performing temperature measurement.
This image illustrates the KAIWEETS HT206D Digital Clamp Meter measuring temperature using the included K-type thermocouple. Examples show measurements in liquid, gas, and solid states, with a temperature range of -4°F to 1832°F.
5.1.3 NCV (నాన్-కాంటాక్ట్ వాల్యూమ్tagఇ) గుర్తింపు
- Press the NCV button (located on the right side of the meter).
- Move the top of the clamp లైవ్ కండక్టర్ దగ్గర మీటర్.
- మీటర్ AC వాల్యూమ్ ఉనికిని సూచిస్తుందిtagవినగల బీప్ మరియు/లేదా దృశ్య సూచిక ద్వారా.

Image 5.1.3: KAIWEETS HT206D Digital Clamp Meter NCV and HOLD functions.
This image demonstrates two functions of the clamp meter. On the left, the NCV (Non-Contact Voltage) function is shown detecting voltage near an outlet. On the right, the HOLD function is activated by a short press of the 'H' button, freezing the display reading.
5.1.4 LowZ & LPF Functions
- LowZ (Low Input Impedance): Helps prevent false readings caused by "ghost voltages" in circuits. Select this mode when ghost voltages are suspected.
- LPF (తక్కువ పాస్ ఫిల్టర్): Used for accurate measurement of variable frequency drive (VFD) signals, common in motor and transformer applications.
5.1.5 Data Hold (MAX/MIN)
- Press the "HOLD" button to freeze the current display reading. Press again to release.
- Press the "MAX/MIN" button to record the maximum or minimum values during a measurement session.
5.2 KAIWEETS 0.8V-100V DC Smart Automotive Test Light
5.2.1 Smart Mode Operation
The test light defaults to Smart Mode, automatically detecting and measuring DC voltage, continuity, and resistance without manual range selection.
- Ensure the alligator clip is securely connected to a ground point.
- Touch the probe tip to the circuit or component to be tested.
- The display will automatically show the detected measurement type (DC Voltage, Continuity, or Resistance) and its value.

Image 5.2.1: KAIWEETS 0.8V-100V DC Smart Automotive Test Light in Smart Mode.
This image highlights the "Smart Mode" feature of the automotive test light, which automatically recognizes and measures DC Voltage, Resistance, and Continuity. The test light is shown in an automotive fuse box, demonstrating its application.
5.2.2 Wide Testing Range (0.8V-100V DC)
The test light can accurately measure DC voltages from 0.8V to 100V. If the voltage exceeds 100V, the display will show "OL" (Overload) as a warning.

Image 5.2.2: KAIWEETS 0.8V-100V DC Smart Automotive Test Light wide testing range.
This image demonstrates the test light's 0.8V-100V wide testing range, showing it connected to a car battery terminal. The display shows a voltage reading, and an inset illustrates the "OL" (Over-range warning) display for values exceeding 100V.
5.2.3 ఫ్లాష్లైట్ మరియు బ్యాక్లైట్
- Press the flashlight button to activate the built-in flashlight for illuminating the work area.
- The green backlight display enhances readability in low-light conditions.

Image 5.2.3: KAIWEETS 0.8V-100V DC Smart Automotive Test Light with flashlight and backlight.
This image shows the automotive test light being used in a dark environment, highlighting its green backlight display and bright flashlight feature, which aids visibility during operation.
5.2.4 Buzzer Alarm for Continuity
When testing for continuity (typically less than 50Ω), the test light will emit an audible buzzer alarm to indicate a continuous circuit.

Image 5.2.4: KAIWEETS 0.8V-100V DC Smart Automotive Test Light buzzer alarm.
This image illustrates the buzzer alarm feature of the test light, which activates when testing for continuity (less than 50Ω). The test light is shown connected to a circuit, with visual cues indicating the sound waves from the buzzer.
6. నిర్వహణ
- శుభ్రపరచడం: ప్రకటనతో పరికరాన్ని తుడవండిamp వస్త్రం మరియు తేలికపాటి డిటర్జెంట్. అబ్రాసివ్లు లేదా ద్రావకాలను ఉపయోగించవద్దు.
- Battery Replacement (HT206D Clamp Meter): డిస్ప్లేలో తక్కువ బ్యాటరీ సూచిక కనిపించినప్పుడు, విభాగం 4.1లో వివరించిన విధంగా బ్యాటరీలను భర్తీ చేయండి.
- నిల్వ: Store the instruments in a cool, dry place, away from direct sunlight and extreme temperatures. If storing for extended periods, remove batteries from the clamp మీటర్.
- Probe and Lead Inspection: Regularly inspect test leads and probes for any signs of damage, such as cuts, cracks, or exposed wiring. Replace damaged components immediately.
7. ట్రబుల్షూటింగ్
| సమస్య | సాధ్యమైన కారణం | పరిష్కారం |
|---|---|---|
| Clamp మీటర్ పవర్ ఆన్ అవ్వదు. | డెడ్ లేదా తప్పుగా ఇన్స్టాల్ చేయబడిన బ్యాటరీలు. | బ్యాటరీ ధ్రువణతను తనిఖీ చేయండి; బ్యాటరీలను భర్తీ చేయండి. |
| Clamp Meter shows "OL" (Overload). | Measurement exceeds selected range or instrument's maximum capacity. | Select a higher range if available, or ensure the measurement is within the instrument's specifications. |
| Clamp Meter current reading is zero. | Clamping around multiple conductors (e.g., a power cord). | cl నిర్ధారించుకోండిamp jaws enclose only a single conductor. |
| Test Light shows "OL". | DC వాల్యూమ్tagఇ 100V మించిపోయింది. | వాల్యూమ్tage is outside the test light's measurement range. Use a different instrument for higher voltages. |
| సరికాని రీడింగ్లు. | Poor contact, damaged leads, or incorrect function selection. | Ensure good contact, inspect and replace leads if damaged, verify correct function is selected. |
8. స్పెసిఫికేషన్లు
8.1 KAIWEETS HT206D Digital Clamp మీటర్
- కొలత విధులు: AC/DC కరెంట్, AC/DC వాల్యూమ్tage, Resistance, Capacitance, Frequency/Duty Cycle, Diode, Continuity, Temperature
- ప్రత్యేక లక్షణాలు: True-RMS, LowZ, LPF, NCV Detection, Data Hold (MAX/MIN)
- భద్రతా రేటింగ్: CAT III 600V (refer to device for exact rating)
- శక్తి మూలం: Battery Powered (e.g., 2x AA 1.5V)
8.2 KAIWEETS 0.8V-100V DC Smart Automotive Test Light
- కొలత విధులు: DC సంtage, Continuity, Resistance (Smart Mode auto-detection)
- పరీక్ష పరిధి: 0.8V - 100V డిసి
- ప్రత్యేక లక్షణాలు: Smart Mode, Flashlight, Green Backlight Display, Buzzer Alarm
- కనిష్ట ఆపరేటింగ్ వాల్యూమ్tage: 0.8 వోల్ట్లు (DC)
- భద్రతా రేటింగ్: 300V CAT III (refer to device for exact rating)
9. వారంటీ మరియు మద్దతు
KAIWEETS products are designed for reliability and performance. For warranty information, technical support, or service inquiries, please refer to the official KAIWEETS webసైట్లో లేదా వారి కస్టమర్ సర్వీస్ను నేరుగా సంప్రదించండి. కొనుగోలు రుజువుగా మీ కొనుగోలు రసీదును ఉంచండి.
KAIWEETS Official Webసైట్: www.kaiweets.com