పరిచయం
This manual provides essential information for the safe and efficient operation and maintenance of your Goodman R-32 HVAC system. This system includes an AC condenser, an 80% AFUE 80k BTU furnace, and a CAPTA3026B3 coil, designed to provide energy-efficient climate control for residential spaces. The system utilizes R-32 refrigerant, offering optimal cooling performance and reduced environmental impact, in compliance with 2025 EPA guidelines and the Montreal Protocol.
ముఖ్య లక్షణాలు:
- శక్తి-సమర్థవంతమైన కంప్రెసర్
- ఫ్యాక్టరీ-ఇన్స్టాల్ చేసిన ఫిల్టర్ డ్రైయర్
- Copper tube with aluminum fin coil
- Thermostat Included
- AHRI సర్టిఫైడ్; ETL జాబితా చేయబడింది
భద్రతా సమాచారం
WARNING: Installation and service of this HVAC system must be performed by qualified, experienced technicians. Improper installation, adjustment, alteration, service, or maintenance can cause property damage, personal injury, or loss of life.
This system uses R-32 refrigerant, which is slightly flammable. Special precautions and equipment are required for handling R-32. Ensure that any service technician is certified and experienced with R-32 systems.
If a refrigerant leak is detected, especially in a system combining an R-32 coil with an older furnace, a safety kit (e.g., a "Dragonfly kit") is crucial. This kit communicates with the furnace to shut off the burner, preventing ignition of the refrigerant. While rare, this safety measure is vital. If replacing only the condenser or the coil, both components must be compatible with R-32 refrigerant. R-410A systems are not backwards compatible with R-32 due to differences in efficiency and refrigerant properties.
వీడియో వివరణ: This video clarifies common misconceptions about R-32 refrigerant, highlighting its widespread use globally and the number of manufacturers currently employing it in their equipment. It emphasizes that R-32 is used in over 130 countries and 230 million systems, and by over 50 manufacturers worldwide as of December 2023.
వీడియో వివరణ: This video provides information regarding current and upcoming refrigerant regulations, particularly focusing on the transition to R-32 refrigerant and its implications for HVAC systems. It discusses the efficiency and environmental benefits of R-32 and the importance of compatible components.
భాగాలు ముగిశాయిview
Your Goodman HVAC system consists of three primary components:
1. Outdoor Condenser Unit (GLXS4BA3010)

చిత్ర వివరణ: A gray Goodman outdoor condenser unit with a fan on top and louvered sides for heat exchange. The Goodman logo is prominently displayed in red on the front.
This unit is responsible for releasing heat from your home to the outside during cooling cycles. It houses the energy-efficient compressor and is designed for durability.
2. Indoor Coil Unit (CAPTA3026B3)

చిత్ర వివరణ: A black Goodman indoor coil unit, rectangular in shape, with copper tubing connections visible on one side. The Goodman logo is visible on the lower front panel.
The indoor coil, also known as the evaporator coil, absorbs heat from the indoor air. This unit features a copper tube with aluminum fin coil for efficient heat transfer.
3. Gas Furnace (GD9S800804BN)

చిత్ర వివరణ: A gray Goodman gas furnace unit, a tall rectangular appliance with a smooth front panel and the Goodman logo in red. Horizontal lines are visible near the bottom.
The 80% AFUE 80k BTU furnace provides reliable heating for your home, utilizing natural gas or liquid propane as its fuel source. It works in conjunction with the indoor coil to circulate conditioned air.
సెటప్ మరియు ఇన్స్టాలేషన్
Due to the complexity and safety requirements of HVAC systems, professional installation by a certified technician is mandatory. This ensures proper sizing, refrigerant charging, electrical connections, and ductwork integration for optimal performance and safety.
సాధారణ సంస్థాపనా పరిగణనలు:
- స్థానం: The outdoor condenser unit should be placed on a level pad, away from obstructions that could impede airflow. The indoor coil and furnace are typically installed in a utility closet, basement, or attic, depending on the home's layout and the furnace's airflow configuration (upflow, downflow, horizontal).
- నాళిక పని: Ensure existing ductwork is clean, properly sealed, and sized correctly for the system's capacity.
- ఎలక్ట్రికల్: Proper electrical wiring and circuit protection are essential. The system operates on 240 Volts.
- శీతలకరణి పంక్తులు: Copper refrigerant lines connect the outdoor condenser to the indoor coil. These lines must be properly sized, evacuated, and charged with the correct amount of R-32 refrigerant.
- గ్యాస్ కనెక్షన్: For the gas furnace, a secure and leak-free connection to the natural gas or liquid propane supply is critical.
- థర్మోస్టాట్: A compatible thermostat (included with the system) should be installed and wired according to the manufacturer's instructions to control heating and cooling cycles.
Do not attempt to install this system yourself. Contact a licensed HVAC professional.
వీడియో వివరణ: This video explains the three main types of HVAC systems: packaged units, ductless systems, and split systems. It details how each system operates and where its components are typically installed, helping users understand their specific setup.
ఆపరేటింగ్ సూచనలు
Your Goodman HVAC system is controlled by a compatible thermostat. Refer to your thermostat's user manual for specific programming and operation details.
ప్రాథమిక ఆపరేషన్:
- పవర్ ఆన్: Ensure the system has power and the thermostat is set to the desired mode (Cool, Heat, Auto, Off) and temperature.
- శీతలీకరణ మోడ్: Set the thermostat to "Cool" and select a temperature lower than the current room temperature. The outdoor condenser and indoor coil will activate to cool your home.
- హీటింగ్ మోడ్: Set the thermostat to "Heat" and select a temperature higher than the current room temperature. The gas furnace will ignite to warm your home.
- ఫ్యాన్ ఆపరేషన్: The fan can be set to "Auto" (runs only when heating or cooling) or "On" (runs continuously to circulate air).
గమనిక:
- Allow a few minutes for the system to respond to thermostat changes.
- Avoid frequently adjusting the thermostat by large increments, as this can reduce efficiency.
నిర్వహణ
Regular maintenance is crucial for the longevity and efficiency of your Goodman HVAC system. It is recommended to schedule professional maintenance annually, ideally before the heating and cooling seasons.
వినియోగదారు నిర్వహణ:
- ఎయిర్ ఫిల్టర్ భర్తీ: Check and replace the air filter monthly, or more frequently if you have pets or allergies. A dirty filter restricts airflow and reduces efficiency.
- క్లియర్ అవుట్డోర్ యూనిట్: సరైన గాలి ప్రసరణను నిర్ధారించడానికి బహిరంగ కండెన్సర్ యూనిట్ చుట్టూ ఉన్న ప్రాంతాన్ని శిధిలాలు, ఆకులు మరియు వృక్షసంపద లేకుండా ఉంచండి.
వృత్తిపరమైన నిర్వహణ (వార్షికంగా సిఫార్సు చేయబడింది):
- Inspect and clean coils (indoor and outdoor).
- రిఫ్రిజెరాంట్ స్థాయిలు మరియు ఒత్తిడిని తనిఖీ చేయండి.
- విద్యుత్ కనెక్షన్లు మరియు భాగాలను తనిఖీ చేయండి.
- అవసరమైన విధంగా కదిలే భాగాలను ద్రవపదార్థం చేయండి.
- Check condensate drain for blockages.
- Inspect furnace burners and heat exchanger.
- Verify thermostat calibration.
Your system includes a factory-installed filter drier, which helps protect the refrigerant system from moisture and contaminants. This component typically does not require user maintenance.
ట్రబుల్షూటింగ్
సేవ కోసం కాల్ చేసే ముందు, ఈ క్రింది సాధారణ సమస్యలను తనిఖీ చేయండి:
| సమస్య | సాధ్యమైన కారణం | పరిష్కారం |
|---|---|---|
| సిస్టమ్ ఆన్ కావడం లేదు | No power, thermostat settings incorrect, tripped circuit breaker. | Check circuit breaker, ensure thermostat is set to desired mode/temperature, check emergency shut-off switch. |
| తగినంత వేడి/చల్లదనం లేదు | Dirty air filter, blocked outdoor unit, low refrigerant, leaky ductwork. | Replace air filter, clear debris from outdoor unit, contact a professional for refrigerant check or ductwork inspection. |
| అసాధారణ శబ్దాలు | వదులుగా ఉన్న భాగాలు, మోటారు సమస్యలు, శీతలకరణి సమస్యలు. | Contact a professional for diagnosis and repair. |
| నీటి లీకేజీ | Clogged condensate drain line. | Clear the drain line (refer to professional guidance or contact a technician). |
| Furnace not igniting | No gas supply, faulty igniter, safety lockout. | Check gas valve, reset system (turn off/on at breaker), contact a professional. |
| R-32 Refrigerant Leak Detected | System malfunction, component failure. | Immediately evacuate the area if a strong odor is present. Contact a certified HVAC technician trained in R-32 systems for immediate repair. Do not attempt to fix yourself. |
For any issues beyond basic troubleshooting, contact a qualified HVAC technician.
స్పెసిఫికేషన్లు
| ఫీచర్ | వివరాలు |
|---|---|
| బ్రాండ్ పేరు | మంచివాడు |
| మోడల్ సమాచారం | GLXS4BA3010CAPTA3026B3GD9S800804BN |
| వస్తువు బరువు | 350 పౌండ్లు |
| ఉత్పత్తి కొలతలు | 29 x 29 x 59.5 inches (Condenser: 29"D x 29"W x 59.5"H) |
| కెపాసిటీ | 2.5 టన్నులు |
| వార్షిక శక్తి వినియోగం | సంవత్సరానికి 2365 కిలోవాట్ గంటలు |
| శబ్దం స్థాయి | 75 డెసిబెల్స్ |
| సంస్థాపన రకం | స్ప్లిట్ సిస్టమ్ |
| ప్రత్యేక లక్షణాలు | Remote Controlled (Thermostat) |
| రంగు | బూడిద రంగు |
| వాల్యూమ్tage | 240 వోల్ట్లు |
| వాట్tage | 6000 వాట్స్ |
| శీతలీకరణ శక్తి | 30000 బ్రిటిష్ థర్మల్ యూనిట్లు |
| శీతలకరణి | R-32 |
| మొదటి తేదీ అందుబాటులో ఉంది | జూన్ 26, 2025 |
వారంటీ సమాచారం

చిత్ర వివరణ: A silver shield badge with a blue ribbon at the bottom. The shield prominently displays "10 YEAR" in large text, and the ribbon reads "LIMITED WARRANTY".
Your Goodman HVAC system comes with a 10-Year Limited Warranty. Please refer to the official warranty documentation included with your product for full terms, conditions, and registration requirements. Proper installation and regular maintenance by a qualified technician are typically required to maintain warranty validity.
మద్దతు మరియు సంప్రదించండి
For technical assistance, service, or warranty claims, please contact your authorized Goodman dealer or a certified HVAC professional. Ensure you have your model number (GLXS4BA3010CAPTA3026B3GD9S800804BN) and serial number ready when contacting support.
For additional information, you may visit the official Goodman website or consult the included user manual.





