పరిచయం:
ENTTEC Pixel controllers support over 20 default pixel protocols. The custom protocol feature allows users to create a custom protocol for pixel fixtures not covered by default protocols without the need for new firmware.
సెటప్ అవసరాలు:
- Datasheet of the desired pixel fixture
- Computer to access the device settings page
- For ENTTEC Ethernet Controller: Device IP address (DHCP or static)
- For DIN PIXIE: EMU Software for configuration
Guide to Custom Protocol Creation:
- Verify datasheet for compatible pixel protocol
- Navigate to the Device’s User Interface to enablethe custom protocol feature
- Adjustthe pixel fixture’s data voltage timing viathe web interface based othe n datasheet
Step 1: Verify Datasheet for Compatible Protocol
- Check the data transmission method from the datasheet
- Identify data transmission method (e.g., D1-D2-D3…Dn or C1-C2-D1-D2…Dn)
- Choose a supported protocol with a similar data transmission method
అనుకూలమైన ఫర్మ్వేర్
కస్టమ్ ప్రోటోకాల్ సృష్టి క్రింది ENTTEC పిక్సెల్ కంట్రోలర్లలో ప్రదర్శించబడుతుంది:
| SKU | ఉత్పత్తి | ఫర్మ్వేర్ వెర్షన్ |
| 73539 | దిన్ పిక్సీ | V2.0 లేదా అంతకంటే ఎక్కువ |
| 70067 | పిక్సెలేటర్ మినీ | V2.0 లేదా అంతకంటే ఎక్కువ |
| 70068 | పిక్సెలేటర్ మినీ MK2 | V1.0 లేదా అంతకంటే ఎక్కువ |
| 71521 | OCTO MK2 | V4.0 లేదా అంతకంటే ఎక్కువ |
| 71522 | OCTO MK3 | V1.0 లేదా అంతకంటే ఎక్కువ |
పరిచయం
- ENTTEC Pixel controllers support more than 20 pixel protocols by default. In the event of missing protocol, this custom feature allows users to create a custom protocol for the desired pixel fixture anytime without having to submit a support request for new firmware.
- ఈ ఫీచర్ వినియోగదారులు వాల్యూమ్ను సర్దుబాటు చేయడానికి అనుమతిస్తుందిtagడేటా ట్రాన్స్మిషన్ పద్ధతి మా మద్దతు ఉన్న ప్రోటోకాల్లలో దేనికైనా సరిపోలితే, మద్దతు ఉన్న ప్రోటోకాల్ల ఆధారంగా ఇ టైమింగ్.
- ఈ పత్రం అనుకూల పిక్సెల్ ప్రోటోకాల్ను సృష్టించడానికి మరియు ప్రమాణాలను ధృవీకరించడానికి సెటప్ సూచనలను అందిస్తుంది.
సెటప్ అవసరాలు
కస్టమ్ ప్రోటోకాల్ను రూపొందించడానికి కిందివి అవసరం:
- డేటాషీట్: Obtain the datasheet of the desired pixel fixture to gather necessary information. Contact the dealer or manufacturer for this document.
- పరికరం: Use a computer to access the device settings page.
- For the TEC Ethernet Controller: Obtain the device IP address, which can be either DHCP or static, based on your network settings. Discover the IP using the ENTTEC EMU app.
- For DIN PIXIE: Use the EMU Software for configuration.
కస్టమ్ ప్రోటోకాల్ సృష్టికి గైడ్
ఈ ఫీచర్ డేటా వాల్యూమ్ను సర్దుబాటు చేయడానికి వినియోగదారులను అనుమతిస్తుందిtage timing to meet specific protocol needs. To create a custom protocol:
- అనుకూల పిక్సెల్ ప్రోటోకాల్ కోసం డేటాషీట్ను ధృవీకరించండి.
- అనుకూల ప్రోటోకాల్ లక్షణాన్ని ప్రారంభించడానికి పరికరం యొక్క వినియోగదారు ఇంటర్ఫేస్కు నావిగేట్ చేయండి.
- పిక్సెల్ ఫిక్చర్ డేటా వాల్యూమ్ను సర్దుబాటు చేయండిtagద్వారా ఇ టైమింగ్ web తయారీదారు డేటాషీట్ ప్రకారం ఇంటర్ఫేస్.
దశ 1: అనుకూల ప్రోటోకాల్ కోసం డేటాషీట్ను ధృవీకరించండి
- డేటాషీట్ నుండి మీరు కోరుకున్న ప్రోటోకాల్ యొక్క డేటా ట్రాన్స్మిషన్ పద్ధతిని ధృవీకరించండి.
- The data transmission method implies how the data is forwarded. Below are demonstrated the common data transmission methods:
- అత్యంత సాధారణ పద్ధతి అదనపు బిట్లు లేకుండా డేటాను ప్రసారం చేస్తుంది (ఉదా, D1-D2-D3...Dn).
Example: WB2812B డేటాషీట్ నుండి సంగ్రహించబడిన సమాచారం
- TM1814 వంటి కొన్ని ప్రోటోకాల్లు ముందు భాగంలో అదనపు డేటాను కలిగి ఉంటాయి (ఉదా, C1-C2-D1-D2...Dn).
Example: TM1814 డేటాషీట్ నుండి సంగ్రహించబడిన సమాచారం
- అత్యంత సాధారణ పద్ధతి అదనపు బిట్లు లేకుండా డేటాను ప్రసారం చేస్తుంది (ఉదా, D1-D2-D3...Dn).
- The data transmission method implies how the data is forwarded. Below are demonstrated the common data transmission methods:
- పరికరం ద్వారా మద్దతిచ్చే మ్యాచింగ్ ప్రోటోకాల్ను నామినేట్ చేయండి (లేదా పైన ఉన్న మాజీ నుండి ఎంచుకోండిample) that shares the same data transmission method as your desired pixel protocol.
- తదుపరి కాన్ఫిగరేషన్ కోసం 2వ దశకు వెళ్లండి.
Step 2: Navigate to the Device’s Settings page to enable the custom protocol feature
In this step, the OCTO/PIXELATOR MINI Series and Din PIXIE are guided accordingly due to their distinct interfaces.
For ENTTEC Ethernet Controllers (OCTO/PIXELATOR MINI Series)
- Access to the OCTO/PIXELATOR MINI web ఇంటర్ఫేస్
- Google Chrome ఇలా సూచించబడింది web browser to access the OCTO/PIXELATOR MINI’s web ఇంటర్ఫేస్.
- Free ENTTEC app, EMU can be used to discover OCTO/PIXELATOR MINI’s IP address. See the ENTTEC webయాప్ను డౌన్లోడ్ చేయడానికి www.enttec.com సైట్ను సందర్శించండి.
- After entering the IP address of OCTO/PIXELATOR MINI, the user will land on the Home page of OCTO/PIXELATOR MINI’s User Interface.

Example of the OCTO homepage in Figure 1 indicates IP address 10.10.3.31, which was assigned by the DHCP server. For the out-of-box OCTO/PIXELATOR MINI that is connected directly to a computer (no DHCP server), the default IP address is 192.168.0.10.
See OCTO/PIXELATOR MINI User Manual ‘Networking’ section for more information.
- Navigate to the Settings page – Output Setting.
కావలసిన పిక్సెల్ ఫిక్చర్ కనెక్ట్ చేయబడిన అవుట్పుట్కి వెళ్లండి. దశ 1లో ధృవీకరించబడిన అదే ప్రసార పద్ధతిని భాగస్వామ్యం చేసే డ్రాప్డౌన్ జాబితా నుండి పిక్సెల్ ప్రోటోకాల్ను ఎంచుకోండి.
- Enable Custom protocol (Continue to Step 3)
డేటా వాల్యూమ్ను యాక్సెస్ చేయడానికి 'కస్టమ్' టిక్ బాక్స్ను ప్రారంభించండిtagఇ టైమింగ్ సెటప్. అనుకూల ప్రోటోకాల్ను నిలిపివేయడానికి ఎంపికను తీసివేయండి.
DIN PIXIE కోసం
- USB టైప్-బిని ఉపయోగించి DIN PIXIEని కంప్యూటర్కు కనెక్ట్ చేయండి.
- EMU సాఫ్ట్వేర్ను ప్రారంభించండి.
- పరికరం కోసం స్కాన్ చేసి, కనుగొనబడిన DIN PIXIE యొక్క కాన్ఫ్పై క్లిక్ చేయండి.

- Enable Custom Protocol (Continue to Step 3)
Pick a pixel protocol from the dropdown list that shares the same transmission method verified in tp,1, and enable Custom.
దశ 3: అనుకూల వాల్యూమ్ను సెట్ చేయండిtagఇ టైమింగ్
- వాల్యూమ్ను సరిపోల్చండిtagమీరు కోరుకున్న ప్రోటోకాల్ డేటాషీట్లో ఇ టైమింగ్. డేటా వాల్యూమ్ను పూర్తి చేయడానికి అనుకూల ప్రోటోకాల్కు 4 ఇన్పుట్లు అవసరంtagఇ సమయ సర్దుబాటు:
వాల్యూమ్tage Timing Definition బిట్ 0 అధిక సమయం (T0H) వాల్యూమ్tagఇ కోడ్ 0 కోసం అధిక సమయం అవసరం. బిట్ 1 అధిక సమయం (T1H) వాల్యూమ్tagఇ కోడ్ 1 కోసం అధిక సమయం అవసరం. Overall Bit Time: మొత్తం వాల్యూమ్tage time for a single bit. Lower limit = T0H+T0L
Upper limit = T1H+T1L
సమయాన్ని రీసెట్ చేయండి మొత్తం వాల్యూమ్tagప్రతి డేటా బ్యాచ్ మధ్య డేటా ట్రాన్స్మిషన్ని రీసెట్ చేయడానికి తక్కువ సమయం అవసరం. 
- డేటాషీట్ - డేటా వాల్యూమ్tagఇ సమయ సమాచారం ఉదాample
WB2818B డేటాషీట్ నుండి- Locate the ‘Sequence Time’ table in WB2818B’s datasheet for the voltagఇ సమయ పరిధి.
- వాల్యూమ్ని పూరించండిtagఅవుట్పుట్ సెట్టింగ్లలో అనుకూల ఫీల్డ్లో ఇ టైమింగ్ పరిధి.

ముఖ్యమైనది
- ENTTEC recommends taking the median value of the range for the start.
- సవరించిన విలువ అమలులోకి రావడానికి వినియోగదారు సెట్టింగ్లను సేవ్ చేయాలి.
- Fine adjustment of value required, followed by actual output test to optimise custom protocol for pixel fixture control.
- ENTTEC recommends a trial run on the actual setup before finalising the custom protocol setup.
- Typical issues of incorrect setup include, including and not limited to, failure to light up and output flickering.
ముగింపు
- అర్హత కలిగిన ENTTEC పరికరాల కోసం అనుకూల ప్రోటోకాల్ను ఎలా సెటప్ చేయాలో ఈ గైడ్ ప్రదర్శించింది మరియు మీరు కోరుకున్న పిక్సెల్ ఫిక్చర్ల డేటాషీట్ను ధృవీకరించడంలో సాంకేతిక పరిజ్ఞానాన్ని అందించింది.
- ఈ దశలను అనుసరించడం ద్వారా, వినియోగదారులు సాంకేతిక మద్దతు లేదా కొత్త ఫర్మ్వేర్ విడుదల కోసం వేచి ఉండకుండా డ్రాప్-డౌన్ జాబితాలో కనిపించని అనుకూల పిక్సెల్ ప్రోటోకాల్ను సృష్టించవచ్చు. మీకు ఏవైనా ప్రశ్నలు లేదా సరైన సమాచారాన్ని కనుగొనడంలో ఇబ్బంది ఉంటే, స్థానిక కార్యాలయాలలో మా స్నేహపూర్వక మద్దతు బృందాన్ని సంప్రదించండి.
తరచుగా అడిగే ప్రశ్నలు
How do I access the device settings page on my computer?
You can access the device settings page by connecting your computer to the device's network and entering the IP address in a web బ్రౌజర్.
Can I create a custom protocol without the datasheet?