Installation and setup Roth Touchline® SL Valve module
- This guide can be followed if your system is only to be set up for heating with following default settings:
- Heating mode: “Heat on demand” (does not require an outdoor sensor)
- Heat demand: Low ≤ 25 W/m², variable supply temperature from 25 – 35°C (in steps of +/-1°C)
- Floor protection: Max. flow temperature 40°C
- For other types of setup, we refer to the full installation instructions and user manual.
Connection to Master/Connection to Extension

Setup – Heat by demand

Device Access and Registration
- Navigate to the “Modules” menu.
- Select “Valve Module” and choose “Register”.
- Enter the registration code: 30914.
- Confirm the registration and wait for the process to complete.
- Upon successful registration, the information will be displayed.