ట్రెండ్-లోగో

ట్రెండ్ IQ500 కంట్రోలర్

TREND-IQ500-Controller-PRODUCT

వివరణ

The IQ500 controller provides a secure and versatile control platform for building and energy management systems. With four onboard Ethernet ports and three RS-485 ports, the IQ500 not only enables the creation of a powerful Trend network but also provides the ability to interface with a wide range of third-party devices using BACnet, Modbus, M-Bus, MS/TP.
The IQ500 integrates with the latest IQ5-IO input/output modules over a high-speed T1L bus. A separate bus is also provided for use with IO modules from the IQ4 and XCITE ranges.
Flexible licensing options allow the IQ500’s functionality and number of IO channels to be easily configured to match your application.

ఫీచర్లు

  • Designed to meet ISA/IEC 62443-4-2, and been developed using processes that are fully certified to ISA/IEC 62443-4-1.
  • Audit logging
  • T1L high-speed secure bus for T1L devices (IQ5-IO modules & IQ5-LAN-ADPT)
  • Compatible I/O bus for IQ4 and XCITE (IQ3) I/O modules
  • Compatibility mode for incorporating into existing Trend systems
  • 1 Isolated Gigabit, and 3 Switched Gigabit Ethernet Ports
  • 3 onboard RS-485 ports for Modbus, M-Bus (via M-Bus convertor), MS/TP and XNC
  • BACnet over IP (BACnet protocol revision 23)
  • Automatic time synchronisation and daylight saving via SNTP
  • DIN rail mounting, DIN 19 size 2 standard enclosure
  • USB local supervisor/engineering port
  • 24 Vac/dc input power supply
  • Multi-State Strategy Modules provide simplified configuration and are automatically mapped to BACnet Multi-State Objects, enabling seamless integration with third-party systems.
  • State Text for Digital Strategy Modules for easy understanding and management of system operations at a glance.

భౌతిక

TREND-IQ500-Controller-FIG-1TREND-IQ500-Controller-FIG-2TREND-IQ500-Controller-FIG-3

గమనిక: An RJ-11 socket is located on the left hand side of the IQ500 and is reserved for future use.

ఫంక్షనాలిటీ

COMPATIBILITY WITH EXISTING SYSTEMS
From v1.10 firmware, the IQ500 is able to coexist on the same Trend network as pre-IQ5 controllers (IQ1, IQ2, IQ3, IQ4, IQECO). To allow this the IQ500 can be configured to operate in one of two modes:

  • IQ5 మోడ్
  • అనుకూలత మోడ్

IQ5 Mode: When in IQ5 Mode, the IQ500 is only able to communicate with other IQ5s in IQ5 mode and IQECO controllers; it will have the latest functionality and will comply with the latest security standards.

అనుకూలత మోడ్: When in Compatibility Mode the IQ500 acts as like an IQ4 controller and is able to communicate with IQ1, IQ2, IQ3, IQ4, and IQECO controllers, and other IQ5 controllers provided they are also in Compatibility Mode. Its security system will operate in the same way as an IQ4 controller to ensure it is compatible with the existing controllers.

గమనిక: Compatibility mode should be used to transition a site to IQ5 Mode, and a plan should be put into place with the building owner for this purpose.

The table below provides a comparison between the two modes:

ఫీచర్ IQ5

మోడ్

అనుకూలత మోడ్
Compatible IQ1, 2, 3 and 4 systems O P
సిస్టమ్ ఖాతాలు P O
Synchronised Account Management P O
Encrypted Trend communications P O
IQ5-IO మాడ్యూల్స్ P P
*IQ4/IO/.. I/O Expansion Modules

*XCITE/IO/.. I/O Expansion Modules

P P
*Use all RS-485 ports for interfacing P P
*IQ Interfacing (ModBus, M-Bus, XNC) P P
*MS/TP router (NC) P P
BACnet P P
Password recovery via email P O
IQVIEW SCD for IQ5 P P
802.1x P O
Trend Current Loop O P
Isolated Ethernet port P O

*Requires Licence
For more details see the IQ5 Configuration Manual (TE201485).

సిస్టమ్

The IQ500 has communication ports for Ethernet, RS-485 and USB, together with T1L and IQ3/4 buses:

TREND-IQ500-Controller-FIG-4

గమనిక: The Current Loop LAN Adapter (IQ5-LAN-ADPT) can be used to enable an IQ5 in compatibility mode to connect to the Trend current loop network – see the IQ5-LAN-ADPT Current Loop LAN Adapter Data Sheet (TA201510).

ఈథర్నెట్ పోర్ట్స్
The IQ500 has four gigabit Ethernet ports connected to two network adapters. Adapter 1 ( 1) is connected to one isolated Ethernet port ( 1). Adapter 2 ( 2) is connected to three switched ports ( 2 ports 1, 2 & 3). Both adapters have unique MAC addresses that can be used to help identify the IQ5 during configuration. All ports support either static or dynamic (DHCP) IP addressing (DHCP by default) and can be individually enabled/disabled and configured. Using daisy-chain/star/tree topologies the ports can be used for:

  • communication with IQ5 Controllers (IQ5 Mode),
  • communication with IQ5 (Compatibility Mode), IQ4, IQ3 controllers, and IQ1 and IQ2 controllers via an NC.
  • IP-based communication with field devices,
  • connection to the IQVISION supervisor,
  • యాక్సెస్ web pages via the onboard web సర్వర్,
  • integration with third party IP systems using XNC

గమనిక: The isolated Ethernet port is not available when the IQ5 is in compatibility mode.
దిగువ రేఖాచిత్రం మాజీని చూపుతుందిample of how a system might be connected using the Ethernet ports:

TREND-IQ500-Controller-FIG-5

Using one of the ports the IQ500 can form a Trend LAN with other IQ5-compatible devices over an Ethernet network:

TREND-IQ500-Controller-FIG-6

The IQ500 has the ability to join an internetwork using its virtual internetwork node controller (vINC). Other devices connected to the Ethernet network can communicate with the IQ500 using IP addressing. Remote PCs can communicate through standard IT networks using IP.

గమనిక: Remote communication with the Trend network by a supervisor, tool or display will require the use of a secure virtual CNC (vCNC) in the IQ500 or another CNC on the network.

ఒక సమగ్ర web interface is also accessible over an Ethernet/IP connection.
The IQ500 supports communication with IP Modbus devices.

Network Service Routing
The IQ500’s network services (vCNCs, Trend IP communication, BACnet IP communication, and Web server) can be routed to either the isolated port or the switched ports.

పోర్ట్ నిర్వహణ
The Ethernet ports can be individually enabled/disabled.

Isolated Port
The isolated port provides a quick way to connect the BMS network to the client’s IT infrastructure.

RS-485 పోర్ట్‌లు
The IQ500 has three galvanically isolated RS-485 ports, each with switchable 120 Ω termination. These can be independently configured to operate using Modbus, M-Bus or XNC functionality.

గమనిక: M-Bus operation will require an RS-485 to RS-232 converter (e.g. the PW60).
If IQ500 is configured as a node controller, one port can be used to connect IQECO controllers on an MS/TP trunk.

USB (Local Engineering Port)
The USB (Local Engineering Port) allows direct connection of IQSET, enabling IQSET to communicate across the entire Trend network.

గమనిక: An additional USB port is located adjacent to Ethernet port 1. This is reserved for future use.

BACnet కమ్యూనికేషన్స్
BACnet is an open protocol that enables the products of a number of different manufacturers of building automation and control equipment to communicate with each other. It supports communication using BACnet over IP (Ethernet,) including:

  • Access to IQ5 parameters over BACnet,
  • Alarm delivery,
  • IC comms to a BACnet device.

A full specification of the objects, properties, and BIBBS (BACnet Interoperability Building Blocks) supported by the IQ500 are given in the IQ5 Protocol Implementation Conformance Statement (TP201479). The mapping of BACnet properties to Trend parameters is described in the IQ5 Configuration Manual (TE201486).

T1L బస్సు

The T1L bus enables the connection of T1L devices (IQ5-IO modules and a single IQ5-LAN-ADPT).
For details of the range of available IQ5-IO modules refer to the IQ5-IO Modules Data Sheet (TA201481). For details of the Current Loop LAN Adapter (IQ5-LAN-ADPT) refer to the Current Loop LAN Adapter Data Sheet (TA201510).
T1L devices can be slotted together, adjacent to the controller (or other T1L devices) with inter-device connections being made via integral spring connectors.

TREND-IQ500-Controller-FIG-7

గమనిక: T1L devices can easily be removed without disturbing adjacent devices Alternatively, T1L devices can be mounted remotely and connected to the T1L bus by means of the IQ5-IO-ADPT wiring adapter and suitable cable.

TREND-IQ500-Controller-FIG-8

గమనిక: The IQ5-IO-ADPT wiring adapter includes a self-resetting fuse and transient voltage suppression that protects the T1L bus from over-current and over-voltagఎలక్ట్రికల్ ట్రాన్సియెంట్స్ లేదా తప్పు వైరింగ్ వల్ల కలిగే ఇ పరిస్థితులు. మెయిన్స్ వాల్యూమ్ యొక్క ప్రమాదవశాత్తు కనెక్షన్ నుండి రక్షణ అందించబడదుtages.

Cabling between devices on the T1L bus may be wired from right to left side, right to right or left to left, as long as correct bus polarity is maintained. Spurs are not permitted.
A cover plate (IQ5-IO-END) must be fitted to the last T1L device on the bus, to protect the exposed bus connectors.
గమనిక: A cover is supplied with each IQ5 controller which can be used for this purpose. A pack of spare covers is also available.

Maximum T1L Bus Length
When designing a system with remote IO you need to be aware that separately powered panels with T1L devices may be switched off and hence the distance between T1L devices may now be X + Y or even X + Y + Z. For this reason, we recommend the distance between panels of IO be no more than the 1/3 of the distance (10 devices off) shown in the table.

TREND-IQ500-Controller-FIG-9

The table below identifies cables that have been tested and the distances which can be achieved between active devices, assuming up to 10 offline devices are between them.

 

కేబుల్

సాధారణ ఉపయోగాలు  

కేబుల్ లక్షణాలు

Max Distance (between

working nodes)

Max Distance (10

devices off)

సిఫార్సు చేయబడింది

1/ Distance (10

3

devices off)

74040NH – Belden T1L- Long-distance harsh environments 2 core solid 18AWG,SF/ UTP Shielded and foil,

unshielded twisted pair.

1000మీ 900మీ 300మీ
8471 – Belden LON 2 core stranded/tinned

16AWG, unshielded cable.

560మీ 504మీ 168మీ
9841 – Belden

TP/1/1/24/200/HF-600V

MSTP (Serial) 2 core stranded/tinned 24AWG, Foil

shield & drain wire, twisted pair.

400మీ 360మీ 200మీ
8723NH – Belden

TP/2/2/22/200/HF-600V

Trend 4 wire LAN 4 core, 2 pairs, stranded/ tinned, 22AWG, Foil shield &

drain wire, twisted pairs.

160మీ 144మీ 48మీ
8761NH – Belden

TP/1/1/22/200/HF-600V

Trend 2 wire LAN 2 core stranded/tinned, 22 AWG, Foil

shield & drain wire, twisted pairs.

320మీ 288మీ 96మీ
5501UE 0081000

– Belden/BAV

Security, speaker, PA, & telephone systems 3 core stranded bare copper, 22 AWG, no shield or twist. 600మీ 540మీ 180మీ
82836 – Helukabel Profibus – Industrial

ఈథర్నెట్

2 core solid, 18AWG Foil +

braided screen twisted pair.

800మీ 720మీ 240మీ
3076F – Belden కఠినమైన వాతావరణం

digital and serial two way communication

2 core solid 18AWG, Shielded and foil, unshielded twisted pairs. 428మీ 385మీ 128మీ
Helukabel J-Y(ST)YLG Telecommunications & Fire Alam Cable (Fire

Warning Cable)

Multicore solid bare copper, 20AWG (0.8mm), foil wrapped. 320మీ 288మీ 96మీ
పిల్లి5/పిల్లి6 Standard wired IT

నెట్వర్క్ కేబుల్

8 core, 4 pairs, solid bare copper,

23AWG, twisted pairs.

720మీ 648మీ 217మీ

విద్యుత్ సరఫరా
IQ5-IO modules and other T1L devices can typically be powered from the controller via the T1L bus supply. This supply is derived from the controller’s 24 Vac/dc supply and, therefore, the maximum current available to the T1L bus depends upon other current demands placed on the controller.

The maximum current required by each T1L device is specified in the appropriate data sheet and can be used to estimate the total current required by the T1L bus:
Where the total current requirement of the T1L bus exceeds the maximum available from the controller, one or more additional 24 Vac/dc power supplies may be installed. Additional supplies may also be required in the following circumstances:

  • at the end of a long T1L bus cable run, to prevent voltagబస్సు సరఫరాలో తగ్గుదల (కనీసం 19V సరఫరా అవసరం),
  • where the current flow through the power line of any one T1L device would exceed the maximum of 2 A, thus requiring the T1L bus power line to be split or segmented.

TREND-IQ500-Controller-FIG-10

అదనపు విద్యుత్ సరఫరా

ముఖ్యమైన: UL-కంప్లైంట్ ఇన్‌స్టాలేషన్‌లకు అనుమతి లేదు.
Where it is necessary to install an additional power supply along the T1L bus, the supply output must be isolated from earth (ground). The supply unit must also comply with the relevant EMC and safety standards.

గమనిక: Trend offer a range of DIN rail-mounted auxiliary power supplies that are suitable for this purpose.
The I/O wiring adapter (IQ5-IO-ADPT) is used to make the connection of external power supply units to the T1L bus as shown below:

TREND-IQ500-Controller-FIG-11

ముఖ్యమైన: The 24 Vdc connection from the previous T1L device must not be made. The 0 V connection must be made when an external supply is used and the 0 V line must be continuous for the entire length of the T1L bus.

Earthing/Grounding Arrangements
It is important that correct earthing/grounding is provided for the controller and devices on the T1L bus.
The T1L bus ground is connected to earth/ground via the controller. T1L devices located within the same secondary enclosure are earthed/grounded via the T1L bus ground connection.
Where T1L devices are located in different secondary enclosures or where T1L bus cables exceed 1 m (39”), a local earth/ground connection must be provided. For further details refer to the IQ5 Installation Instructions – Mounting (TG201484).
అన్ని DIN పట్టాలు తప్పనిసరిగా ఎర్త్/గ్రౌండ్ చేయబడాలి.

IQ3/4 Bus
The IQ3/4 bus allows the IQ500 controller to be used in conjunction with both IQ4 and XCITE I/O modules. This bus must be enabled using an optional CAN licence7.
Up to 30 modules can be connected to the IQ3/4 bus, depending on the module range(s).

మాడ్యూల్ పరిధి IQ4/IO only IQ4/IO and/or XCITE/IO
మాడ్యూళ్ల సంఖ్య 30 15

గమనిక: Modules connected to the IQ3/4 bus cannot be powered from the IQ500 controller and must be provided with one or more separate 24Vdc power supplies.
For further details see the IQ4/IO Modules Data Sheet (TA201341) and the XCITE/IO Modules Data Sheet (TA201352).

Trend Current Loop
When in compatibility mode the IQ500 can be configured to connect to a Trend current loop LAN or internetwork via the Current Loop LAN Adapter (IQ5-LAN-ADPT) – see the IQ5-LAN-ADPT Current Loop LAN Adapter Data Sheet (TA201510).

గమనిక: For connection to a Trend current loop internetwork.

Modbus and M-Bus Interfacing
The IQ500 can be configured to communicate with Modbus devices enabling it to be easily integrated with many third party devices including meters, sensors, and variable speed drives.

గమనిక: Modbus and M-Bus functionality needs to be enabled using an optional INT licence.
Standard strategy blocks, available in IQSET, allow easy strategy configuration using drag and drop for common Modbus and M-Bus devices.
Engineering with standard Network and Interface modules allows connection to other Modbus or M-Bus devices. Strategy blocks can be created for favourite devices.

మోడ్బస్
IQ500 can be configured to communicate with Modbus devices over IP (using the onboard Ethernet ports) or the RS-485 ports.

* Maximum number of inputs/outputs per device: Each Modbus Interface module can have up to 500 inputs/outputs. If more than this is required additional Modbus Interface modules can be connected to the same Modbus address (device).
* గమనిక: Total number of inputs/outputs is limited by the number of licensed interface points.

  • Maximum number of devices: Although the maximum number of Modbus devices connected to the IQ500 is determined by the number of available interface modules in the IQ500 (max 1000), in reality, the limit is set by the Modbus rules or the IQ500 integration license.
  • Maximum number of connected Modbus networks: Each connected network requires one Modbus Network module. There is a maximum of 10 Modbus IP network modules. For Serial
  • Modbus network modules, the number is set by the IQ500’s hardware.
  • Devices from different manufacturers can be connected to the same network provided the network parameter configuration are the same.

గమనిక: IQ500 cannot operate as a subordinate, so does not have registers.

M-బస్సు
IQ500 can be configured to communicate with M-Bus devices using the RS-485 ports in conjunction with a suitable RS-485 to RS-232 converter (e.g. the PW60).
*Maximum number of outputs per device: Each M-Bus Interface module can have up to 1000 outputs, which allows 1000 outputs per device. If more than this is required additional M-Bus Interface modules can be connected to the same M-Bus address (device).

*గమనిక: Total number of outputs is limited by the number of licensed interface points.

గమనిక: An individual M-Bus device is limited to 255 values. Therefore, although there can be 1000 outputs on the interface module, each one can only be set to one of 255 values from the M-Bus device.
Maximum number of devices: Although the maximum number of interface modules is 1000, the maximum number of M-Bus devices is limited to 250 but is dependent on the M-Bus converter used.

*గమనిక: Total number of outputs is limited by the number of licensed interface points.

When values are requested from an M-Bus device ALL values are sent to the IQ500. For example, when requesting a single value from an M-Bus device that has 20 values the M-Bus device will send all 20 values to the IQ500. Therefore, it is necessary to consider the data flow rate.

గమనిక: The more values and devices that are required the larger the strategy requirements. Therefore, the brIQ count must be considered.
Maximum number of connected M-Bus networks: Each connected network requires one M-Bus Network module. The number of M-Bus network modules is set by the IQ500’s hardware.
Devices from different manufacturers can be connected to the same network, provided the network parameter configuration is the same.

XNC Functionality
The IQ500 supports the use of XNC functionality, enabling the Trend system to interface with third party systems. It utilises standard IQ strategy modules in conjunction with the Trend Custom Language (TCL) to present information from other systems as though it is from an IQ controller. It also allows parameters within the third-party system to be adjusted from Trend supervisors and software tools.

XNC communication with third party systems can be over Ethernet or RS-485, and with other Trend devices over Ethernet.

గమనిక: XNC functionality needs to be enabled using an optional INT licence.

Node Controller Operation
The IQ500 can be licensed for Node Controller operation. It can be configured to operate in one of four modes:

    • Ethernet Internetwork to MS/TP LAN Mode
    • Trend Internetwork to MS/TP Mode
    • Ethernet to Trend LAN Mode
    • Ethernet to Trend Internetwork Mode
  • Ethernet Internetwork to MS/TP LAN Mode: Available in both IQ5 Mode and Compatibility Mode this mode enables it to connect a LAN of IQECO controllers on an MS/TP RS-485 trunk to a Trend internetwork on Ethernet.
  • Trend Internetwork to MS/TP Mode: Only available in Compatibility Mode and requires an IQ5-LAN-ADPT. This mode enables the IQ5 to act as an interface between an internetwork on a Trend current loop network and an IQECO LAN on the MS/TP trunk.
  • Ethernet to Trend LAN Mode: Only available in Compatibility Mode and requires an IQ5-LAN-ADPT. This mode enables the IQ5 to act as an interface between an internetwork on Ethernet and a LAN on the Trend current loop network.
  • Ethernet to Trend Internetwork Mode: Only available in Compatibility Mode and requires an IQ5-LAN-ADPT. This mode enables the IQ5 to act as an interface between an internetwork on Ethernet and an internetwork on the Trend current loop network.
  • గమనిక: Node Controller functionality needs to be enabled using an optional NC licence. Only one RS-485 port can be enabled for MS/TP.

నెట్వర్కింగ్
In order to connect to the Trend network the IQ500 will create its own internal LAN, which includes the following nodes:

  • a CNC for its own controller,
  • a supervisor CNC (sCNC) for its USB port,
  • four virtual CNCs (vCNC1, vCNC2, vCNC3 and vCNC4), and
  • a virtual INC (vINC).

TREND-IQ500-Controller-FIG-12

  • CNC Functionality: When a PC running IQSET is connected to the USB port it uses an sCNC. If the USB port address is set to 0 (default), the sCNC is dynamically created at address 125 for the duration of the IQSET session. When the PC is removed the sCNC times out and no longer exists on the network. If the address is configured to be non-zero, the sCNC remains on the network at all times.
  • CNC Functionality: vCNC Functionality: Allows a supervisor/tool/display to make a permanent, secure connection to the Trend network using TCP/IP. By default all vCNCs are disabled. The standard IQ500 has four vCNCs, which increases to eight when operated as a Node Controller (with an NC licence).
  • INC Functionality: When the IQ500 joins a LAN on Ethernet, the controller with the lowest IP address assumes INC functionality (using its vINC at address 126); any vINCs in other controllers on that LAN will automatically be disabled.
  • IC Comms: When in IQ5 Mode the IQ500 can communicate with other IQ5s in IQ5 mode, IQECOs, and BACnet devices using IC Comms. Some IQECOs running earlier versions of firmware may not support all IC Comms types..

When in Compatibility Mode, the IQ500 can communicate with other IQ5s in Compatibility Mode, IQ4s, IQ3s, IQ2s, IQ1s and IQECOs and BACnet devices using IC Comms in the same way as an IQ4.

ఇన్‌పుట్‌లు మరియు అవుట్‌పుట్‌లు
The IQ500 does not include any onboard analogue or digital I/O but has two buses for the connection of expansion modules.

  • T1L Bus – for T1L devices (IQ5-IO modules and IQ5-LAN-ADPT
  • IQ3/4 Bus – for IQ4/IO and XCITE/IO (IQ3) modules

The IQ500 ships with a base licence supporting up to 16 channels/points, which is expandable up to 300 points. The total licenced point count is shared between both buses.

హార్డ్వేర్

ఎన్ క్లోజర్
The IQ500 is housed in a polycarbonate enclosure compatible with the DIN43880 and DIN 19 size 2 standard. Integral clips on the back of the enclosure enable the unit to be clipped on to (and quickly released from) a standard TS35 DIN rail.
It must be installed in a secondary enclosure with a minimum protective rating of IP20 (or equivalent).
The unit may be mounted horizontally or vertically but not upside down or on its back:

TREND-IQ500-Controller-FIG-13

తొలగించగల క్లిప్-ఆన్ పాలికార్బోనేట్ కవర్లు వివిధ ఆన్‌బోర్డ్ టెర్మినల్ కనెక్షన్‌లకు యాక్సెస్‌ను అందిస్తాయి.

TREND-IQ500-Controller-FIG-14

Spare covers are available

టెర్మినల్ కనెక్టర్లు
Connection for power, RS-485 and IQ3/4 bus is via two-part pluggable screw terminal connectors which are supplied as standard with the controller and available in packs for spares. Optional connectors with push-fit terminals are also available.

TREND-IQ500-Controller-FIG-15

ఇన్పుట్ పవర్ సప్లై
The IQ500 requires a 24 Vac/dc power supply rated as follows:

  • 24 Vac ±20%, 50/60 Hz, 34VA (1.42A);
  • 24 Vdc ±20%, 12.5W (0.52A).

If T1L devices (IQ5-IO modules and IQ5-LAN-ADPT) are to be powered from the controller’s T1L bus, the above rating must be increased to take account of the additional load. Refer to the IQ5-IO Modules Data Sheet (TA201481) or IQ5-LAN-ADPT Current Loop LAN Adapter Data Sheet (TA201510) for details of T1L device power consumption.

The local earth terminal must be earthed (grounded) at the controller. The 24 V supply must include a suitably rated switch in close proximity and be clearly marked as the disconnecting device for the unit. Do not position the equipment so that the disconnecting device is difficult to operate. Wiring exampలే:

TREND-IQ500-Controller-FIG-16

TREND-IQ500-Controller-FIG-17సర్వీస్ బటన్
The service button is located behind the drop-down fl ap located on the front of the IQ500. It has the following functions:

  • To identify the IQ500 to IQSET during commissioning,
  • To return the IQ500 to its factory default settings.

సూచికలు
Various indicators are provided on the IQ500 giving feedback on its operational status.

General (located on the front panel):

TREND-IQ500-Controller-FIG-18

Ethernet: (located adjacent to each Ethernet connector):

TREND-IQ500-Controller-FIG-19

బ్యాకప్
In the event of an interruption to the power supply, the IQ500 uses the following mechanisms to retain data until power is restored. Controller data (including firmware, strategy ,and parameter values) is stored in non-volatile eMMC memory. Live data, which includes last known values, is stored in non-volatile FRAM.
A supercap is used to maintain the real time clock (RTC). In the event of power failure, this will typically maintain the time and date function for up to 3 days.

గమనిక: Operation at elevated temperature or high humidity levels may reduce the lifetime of the supercap. Extended operation in these conditions may permanently reduce the capacity of this component and result in a reduction in the number of days that the controller can successfully backup the time and date.

లేబులింగ్
Two removable self-adhesive labels detailing the serial number (SN) and Ethernet MAC address (EN1 MAC) of the IQ500 controller are supplied which can adhered to plant room panels, cabinets or schematic plans as required:

TREND-IQ500-Controller-FIG-20

The serial number comprises the following manufacturing and product information:

TREND-IQ500-Controller-FIG-21

The serial number is also provided as a QR code, and the MAC address is provided as a barcode (in Code 128 format) such that both can be read using a suitable hand-held scanner.
A non-removable label containing the same information is fi xed to the inside of the drop-down fl ap on the controller’s front panel.
A third self-adhesive label detailing licences included with the controller when shipped from the factory and the serial number (SN) is fi xed behind the drop-down fl ap.

TREND-IQ500-Controller-FIG-22

The QR code provides a comma-separated scannable format of the Part number, description & serial number.

ఫర్మ్‌వేర్

The firmware in the IQ500 controls its basic functionality and provides a range of modules that can be configured to produce a control strategy.

వ్యూహం

In order to run sequences of operation for equipment and building control, the modules provided by the firmware must be configured to define the way the controller is to control the connected equipment. This configuration is known as the strategy. Strategies are configured using the System Engineering Tool (IQSET).
This produces a strategy file (filename.IQ5) that can be downloaded to the controller to define its operation. This file consists of all the strategy module instances, their parameters, and links. When this is downloaded, it is stored in the controller and then run using the controller firmware.
For details of using IQSET see the System Engineering Tool Manual (TE200147).

Strategy Modules
The range of strategy modules provided in the IQ5 firmware are listed in the table below. Full details of each module can be found in the IQ5 Configuration Manual (TE201486).

మాడ్యూల్ brIQs Max. number of Modules గమనిక
చిరునామా 24 1 (స్థిరమైనది)  
Alarm Destination 14 8  
Alarm Group 9 500  
Alarm Route 9 500  
అలారం లాగ్ 0 1 (fixed) 2000 records  
Analog Node 16 4000  
క్యాలెండర్ 566 100  
Digital Byte 16 4000  
డిజిటల్ ఇన్పుట్ 28 4000 1
డైరెక్టరీ 13 1000  
ప్రదర్శించు 19 4000  
డ్రైవర్ 61 1000 1
ఫంక్షన్ 19 4000 1
IC Comms 19 2000 (on IP network)

500 (on MS/TP/current loop)

1 4
ఇంటర్ఫేస్ 130 1000 1 3
I/O మాడ్యూల్ 14 283  
నాబ్ 13 4000  
తర్కం 19 4000 1
లూప్ 55 1000  
Multistate Selector 17 4000  
మల్టీస్టేట్ ఇన్‌పుట్ 77 4000  
Network Service/ Network 0 Max 10 Modbus IP  
NTD 30 4000  
ఎంపిక 0    
OSS 34 500  
పేజీ 4 500  
ప్లాట్లు 12 4000  
కార్యక్రమం 0 1 (స్థిరమైనది)  
Schedule Offset 21 4000  
సెన్సార్ 76 4000 1
సెన్సార్ రకం 12 99  
క్రమం 106 1 (స్థిరమైనది) – see separate table for maximum steps  
భద్రత 0 1 (స్థిరమైనది)  
States Category 0 100  
మారండి 10 4000  
సమయం 38 1 (స్థిరమైనది)  
సమయ షెడ్యూల్ 566 100 2
స్థానిక వినియోగదారు 12 500  
Virtual CNC 9 4 (fixed); 8 (with NC licence)  
   The number of brIQs used on these modules varies with the module type. The largest size is shown here.

‚ Includes a maximum of 50 exceptions per module.

ƒ Additional brIQs are required per input and output: XNC 5; Modbus Input 16, Output 15; M-Bus Output 12.

„ For IP networks, a maximum of 2000 IC comms/COV subscriptions can be configured but there is a maximum transmission rate of 300 IC comms/COV subscriptions per minute. For MS/TP and Trend current loop networks, a maximum of 500 IC comms/COV subscriptions can be configured but there is a maximum transmission rate of 100 IC comms/COV subscriptions per minute shared between the two networks.

For more details, see the IQ5 Configuration Manual (TE201485).

The quantity of each type of module may be adjusted to match the requirements of the application subject to the following:

  • a maximum of 4000 modules in total,
  • the maximum for each type of module, and
  • the IQ500’s memory capacity (measured in ‘brIQs’).

The maximum number of modules for each type, and number of brIQs required per module are shown in the table above.

The total available memory capacity varies according to the number of licenced I/O channels:

Number of I/O channels Max. brIQs available
16 30,000
50 40,000
100 60,000
150 90,000
200 120,000
250 150,000
300 180,000

గమనిక: If the IQ5-INT-50 or IQ5-INT-50-UP licence is applied these values are increased by 15,000. If the IQ5-INT-2500 or IQ5-INT-2500-UP licence is applied these values are increased by 50,000.

Plot Modules
The IQ500’s Plot modules can plot the value of any connectable module output (analogue or digital) at a specific interval of between 1 second and 24 hours. There are four types of Plot module: Synchronised, Triggered, Periodic and COV (change of value). Although all four types are BACnet interoperable, only periodic plots can be compliant with the BACnet standard. All Plot modules can generate a buffer ready alarm when the number of records equals a notification threshold.

The maximum number of records per plot is 1000. The maximum total number of records (for all plots) depends on the available plot memory (measured in log points) and the type of plots used:

Maximum plot memory (log points) 3,000,000
రికార్డుల గరిష్ట సంఖ్య Synchronised plots

ఒకే ఖచ్చితత్వం

(5 log points per record)

రెట్టింపు ఖచ్చితత్వం

(10 log points per record)

 

600,000

 

300,000

Triggered, COV or periodic plots

ఒకే ఖచ్చితత్వం

(10 log points per record)

రెట్టింపు ఖచ్చితత్వం

(15 log points per record)

 

300,000

 

200,000

గమనిక: A maximum of 100 plots can be serviced in a 1 s period (e.g. 100 x 1 s plots only). This is calculated on the average plots serviced in 1 s, so a 1 minute plot would contribute a 1/60. For example, 90 x 1 s plots plus 360 x 1 min plots would give 96 (90+6) plots per second on average. The periodic and triggered plots must also be counted, and it is up to the engineer to make their best estimate.

Sequence Table Module
The maximum number of steps in the sequence table varies with the number of licensed I/O channels:

Number of I/O channels Max. sequence steps
16 600
50 750
100 1500
150 2250
200 3000
250 3750
300 4500

గమనిక: If the IQ5-INT-2500-BASE or IQ5-INT-2500-UP licence is applied these values are increased by 1,000.

BACnet COV Reporting and Receiving
The IQ500s BACnet Change Of Value (COV) services allow a COV client to receive reports from a COV server when the value of a referenced property changes. IQ500 provides both COV reporting and COV receiving facilities.
ఫర్మ్‌వేర్ నవీకరణలు
ఫంక్షనాలిటీని మార్చడానికి లేదా జోడించడానికి లేదా కొత్త ఉత్పత్తులకు మద్దతుని అందించడానికి ఫర్మ్‌వేర్ యొక్క కొత్త వెర్షన్‌లు ఎప్పటికప్పుడు అందుబాటులో ఉంచబడతాయి.
Firmware can be upgraded using a PC running the IQTool Firmware Upgrade Applet, and to the IQ500 connected over Ethernet or the USB Engineering Port.
Timemaster
The IQ500 can act as a system Timemaster to synchronise the time and date across the Trend system. It can use SNTP (simple network time protocol) to obtain the precise current time from an unauthenticated NTP server on the Internet. Daylight saving can be implemented automatically (via timezone setting) or manually by specified dates and time adjustments.
అలారాలు
The IQ500 will generate Network, General, and Item alarms. Network alarms are generated by the Trend Network nodes, General alarms are generated when the IQ500 detects a problem within its own hardware or program, and Item alarms are generated by the strategy and are normally due to a faulty plant condition.

Network alarms are sent to supervisors or tools connected to the USB local engineering port, or to one of the controller’s vCNCs.
General and Item alarms can be sent either to a designated Trend LAN address, to an IP address, or as an email. Alternatively, certain Item alarms (e.g., sensor, digital input, digital driver readback, and plot), can be sent to a BACnet device.

Alarms sent to a Trend LAN address, or to an IP address, can either be sent in text, coded, or attribute format. Network alarms are sent in text format only.

For coded alarms, the protocol limits the item number to 255 maximum. For text alarms the maximum item label length is 20 characters.

Sending an alarm by email requires the Email Server Address to be set up in the Address module. The Email Server Address can be an IP address, an internet domain name, or a host name; the internet domain name or host name require a DNS server address or a WINS server address, respectively to be set up in the network module so that the name can be resolved.

All alarms (except Network alarms) are also stored locally in the Alarm Log. The alarm log can record up to 2000 alarms. Once this limit is reache,d each new alarm will overwrite the oldest record.

Web సర్వర్
Information from the IQ500 can be viewed or adjusted from a web client (PC, tablet, or smartphone) over any TCP/IP network (e.g. company intranet) using secure HTTPS protocol. All that is required is the IQ500’s IP address or host name, and a user name and password. Once a connection to the controller has been made, it is possible to view/adjust occupation times, view the alarm log, and view/adjust/graph individual module parameters.
TREND-IQ500-Controller-FIG-23

ది web interface does not allow the strategy structure to be modifi ed (e.g. adding or deleting modules, or changing module interconnections).
Graphical display pages (GraphIQs), which are confi gured using IQ500’s display and directory modules, can also be accessed.

TREND-IQ500-Controller-FIG-24

యొక్క మరిన్ని వివరాల కోసం web Configuration Manual (TE201485), the IQ5 User Manual (TE201490), and the Graphical Display Pages Editor Manual (TE200629).

భాష
The user can specify which language the IQ500 uses for the display of web pages and for transmitted alarms. The standard languages are in the controller as supplied. In the controller the Address module has a language parameter which will be set to the default language, but can be changed to any one of the other available languages. The IQ500 can use languages which require 8 bit code (i.e. special or accented characters) and can also operate with right to left languages (e.g. Chinese, Arabic).

గుర్తింపు కేషన్
When in IQ5 Mode the IQ500 will identify itself as an IQ5 to w comms. When in IQ5 Compatibility Mode the IQ500 will identify itself as IQ4 v5 to w comms.

భద్రత
IQ500 is designed to meet ISA ISA/IEC 62443-4-2, and has been developed using processes that are fully certifi ed to ISA/IEC 62443-4-1. To meet these requirements, IQ500 provides:

  • సురక్షిత బూట్
  • Authenticated and Encrypted Network
  • Encrypted at Rest
  • Synchronised Account Management
  • Audit logging

In the event of a forgotten password, an engineer can initiate an unlock code to be sent to a pre-defi ned email address.
All of this is managed by an admin account which should be provided to the site owner.
It is not recommended that IQ500 is directly connected to the Internet.

Synchronised Account Management: IQ500 features an account management system that provides the engineer with a single logon for the site, and synchronizes any password changes across the whole site.

Audit logging: From V2.0 fi rmware the IQ500 provides audit logging which can be viewed from the IQ500’s web pages for:

  • యాక్సెస్ నియంత్రణ
  • Request errors
  • Operating system events
  • Control system events
  • Backup and restore events
  • Configuration changes
  • Reconnaissance activities
  • Audit logging events

IEEE 802.1X: From V2.0 fi rmware the IQ500’s isolated Ethernet port can be configured to use IEEE 802.1X EAP-TLS authentication. This enables the connection to the IQ500 to be authenticated and ensures that the IQ500 can meet the cybersecurity requirements of sensitive sites, ensuring traffic between the BMS network and the client network is only allowed with authenticated devices.

ముఖ్యమైన: Operating the IQ500 in Compatibility Mode will cause the IQ500 to operate using the same security mechanisms adopted for IQ4-based systems.

లైసెన్సింగ్

All IQ500s have the same base level capacity/functionality i.e. IQ5 Mode or Compatibility Mode, 16 I/O points, T1L bus, Trend communication over Ethernet and BACnet IP communication.

Additional capacity/functionality can be added to an IQ500 by applying a licence to the controller. There are two types of licences Base and Upgrade:

Base Licences
Base licences are used for the initial licensing of the controller i.e., during installation/commissioning. From V2.0 firmware base licenses can be applied to the controller during the grace period after this an upgrade licence must be used to add to the controller’s capacity/functionality.

గ్రేస్ పీరియడ్: From IQ5 firmware V2.0, the grace period is 60 days of power-on time following the application of the initial base license. Within this timeframe, additional base licenses may be added. The initial base license is applied either prior to shipment for pre-licensed controllers or by IQSET for unlicensed controllers. The grace period is visible in IQSET’s IQ5 feature licenser and the IQ5’s web pages in the address module. Prior to IQ5 firmware V2.0, no grace period existed; only the first download of BASE licenses were allowed and the Upgrade licenses had to be applied.

గమనిక: IQ5’s upgraded to V2.0 will only receive the grace period if they have not yet received a base license; if they have a base license only Upgrade licenses can be used.

Licensing Process

TREND-IQ500-Controller-FIG-25

Upgrade Licences
Upgrade licenses are used allow for system expansion after the grace period.

Licences can either be applied in the factory (pre-licensed controllers) or by the engineer using IQSET once the controller hardware has been delivered.
Pre-Licensed Controllers
Pre-licensed controllers are IQ500 controllers that are supplied from the factory licensed with additional functionality. The pre-licensed controllers available have been selected to ensure that the most common capacity/functionality combinations are available directly from the factory. If these don’t meet the requirements base or upgrade licences can be used to add to the pre-licensed controller’s capacity/functionality.
Hardware Only Controllers
Hardware-only controllers are IQ500 controllers that are supplied from the factory with only the base level functionality and require either a base or upgrade licence to be applied using IQSET if additional capacity/functionality is required.

ఫీల్డ్ మెయింటెనెన్స్

The IQ500 requires no routine maintenance.

హెచ్చరిక: సేవ చేయదగిన భాగాలను కలిగి ఉండదు. యూనిట్ తెరవడానికి ప్రయత్నించవద్దు. పాటించడంలో వైఫల్యం యూనిట్‌కు నష్టం కలిగించవచ్చు.

పారవేయడం

COSHH (Control of Substances Hazardous to Health – UK Government Regulations 2002) ASSESSMENT FOR DISPOSAL OF IQ500.
రీసైక్లింగ్ TREND-IQ500-Controller-FIG-26.
All plastic and metal parts are recyclable. The printed circuit board may be sent to any PCB recovery contractor to recover some of the components for any metals such as gold and silver.

TREND-IQ500-Controller-FIG-27WEEE ఆదేశం:
వారి ఉపయోగకరమైన జీవితం ముగింపులో ప్యాకేజింగ్ మరియు ఉత్పత్తిని తగిన రీసైక్లింగ్ కేంద్రం ద్వారా పారవేయాలి.
సాధారణ గృహ వ్యర్థాలతో పారవేయవద్దు. కాల్చవద్దు.

అనుకూలత

బ్రౌజర్‌లు: This device has been successfully tested with the latest versions of browsers typically found on most PCs, smartphones, and tablets.

Supervisors and Displays:

  • IQ5 Mode – IQVISION V4.15 u2 (or later), IQVIEW Single Controller Display for IQ5.
  • Compatibility mode – IQVISION V4.15 u2 (or later), IQVIEW Single Controller Display for IQ5, 963 and IQVIEW8.

గమనిక: A supervisor connected to the USB Local Engineering Port of an IQECO cannot see IQ5 devices.
యుటిలిటీ సాఫ్ట్‌వేర్: IQSET V8.60 (or later).

T1L Devices:

  • IQ5 Mode – IQ5-IO Modules
  • Compatibility mode – IQ5-IO Modules, IQ5-LAN-ADPT

To ensure compatibility and follow cyber security best practices, when installing an IQ5 controller or adding/replacing IQ5 on an existing controller, always ensure that the IQ5 is running the latest version of firmware available from PNet. (https://partners.trendcontrols.com).
IQ3/4

బస్సు: IQ4/IO Modules, XCITE/IO (IQ3) Modules

కంట్రోలర్లు:

  • IQ5 Mode – IQ5s in IQ5 Mode (via Ethernet), IQECO (via RS-485 configured as MS/TP).
  • Compatibility mode – IQ5s in Compatibility Mode (via Ethernet), IQ4 (via Ethernet), IQ3 (via Ethernet) IQECO (via RS-485 configured as MS/TP).

IQ5s in compatibility mode will also be able to communicate with IQ4, IQ3, IQ2 and IQ1 controllers via Trend current loop providing the link to the current loop is made by a non IQ5 device e.g. IQ4NC or the Current Loop LAN Adapter (IQ5-LAN-ADPT) is used.

వ్యూహాలు: IQ1, IQ2, IQ3, IQ4 can be imported into IQSET, converted into IQ5 strategies, and then downloaded into an IQ500.

IC Comms:

  • IQ5 Mode – IQ5s in IQ5 Mode, IQECO
    గమనిక: IC Comms originating from an IQECO cannot be sent to an IQ500 in IQ5 Mode. To obtain a value from an IQECO, the IQ500 must request it. See the IQ5 Configuration Manual for further details.
  • Compatibility mode – IQ5s in Compatibility Mode, IQ4, IQ3, IQ2, IQECO, and IQ1 (v3 onwards).
    గమనిక: Some controllers running earlier versions of firmware may not support all IC Comms types. Refer to the IQ4 Configuration Manual (TE201263) for full compatibility details.

BACnet Devices: The IQ500 controller is a BACnet Building Controller (B-BC). Compatibility is defined in the IQ5 Product Implementation Conformance Statement (TP201479).

సంస్థాపన

The IQ500 is designed to be clipped onto a TH35x7.5 or TH35x15 DIN rail. The IQ500 must be installed in a secondary enclosure with a minimum protective rating of IP20 (or equivalent).

సంస్థాపనా విధానం వీటిని కలిగి ఉంటుంది:

  • Mounting the controller in position
  • శక్తిని కలుపుతోంది
  • Connecting Ethernet network(s)
  • Connecting RS485 networks (if required)
  • Mounting and connecting I/O modules (if required) Mounting and connecting Current Loop LAN Adapter (if required)
  • పవర్ అప్
  • Setting up Ethernet connectivity
  • Creating a strategy
  • కంట్రోలర్‌కి కనెక్ట్ చేస్తోంది
  • Setting up feature licensing
  • కాన్ఫిగర్ చేస్తోంది web server (if required)
  • Setting up NC functionality (if required), downloading strategy and other configuration files Checking BACnet communications
  • Connecting inputs and checking operation Connecting outputs and checking operation

A full description of installing the unit is given in the IQ500 Installation Instructions – Mounting (TG201482) and IQ5, IQ5-IO Installation Instructions – Configuring (TG201483).

ఆర్డర్ కోడ్‌లు

HARDWARE ONLY CONTROLLERS
Hardware-only controllers are supplied with base-level functionality and require either a base or upgrade licence to be applied using IQSET if additional capacity/functionality is required.

IQ5-00-24 

IQ500 with 0 onboard I/O, licensed to 16 I/O channels, expandable to 300 I/O channels, BACnet communications, 24 Vac/dc supply.

PRE-LICENSED CONTROLLERS
Pre-licensed controllers are IQ500 controllers (IQ5-00-24) that have been licensed in the factory with additional functionality.

గమనిక: From V2.0 firmware base licences can be added to a pre-licensed controller to add additional capacity/functionality during the grace period. After the grace period upgrade licences must be used to add capacity/functionality.

The pre-licensed controller order codes (Short Description) are in the format below:
IQ5-00-<IO Capacity>-<Integration Capacity>-<Network Routing>-<IQ3/4 Bus>-<SCD Support>-24-<IO Module>

కోడ్ ఎంపికలు వివరణ
<IO Capacity> 16, 50, 100, 150 The number of IO channels, shared between T1L bus and IQ3/4 bus (if licensed).
<Integration Capacity> 50, 250, 2500 The number of integration points (Modbus, M-Bus and XNC).
<Network Routing> NC NC functionality.
<IQ3/4 Bus> చెయ్యవచ్చు IQ3/4 bus functionality
<SCD Support> SCD IQVIEW SCD functionality
<IO Module> 16UIO Controller supplied with an IQ5-IO-16UIO module

ముఖ్యమైనది: When ordering the pre-licensed controllers, the Part number MUST be used.

Controller with I/O Capacity

సంక్షిప్త వివరణ Part Number / Product Code వివరణ
IQ5-00-50-24 IQ500-50X000000000 IQ500 licensed for 50 I/O channels.
IQ5-00-100-24 IQ500100X000000000 IQ500 licensed for 100 I/O channels.
IQ5-00-150-24 IQ500150X000000000 IQ500 licensed for 150 I/O channels.

To add an IQ5-IO-16UIO module:

సంక్షిప్త వివరణ Part Number / Product Code వివరణ
IQ5-00-50-24-16UIO IQ500-50X0000000K1 IQ500 licensed for 50 I/O channels and a IQ5-IO-16UIO module.
IQ5-00-100-24-16UIO IQ500100X0000000K1 IQ500 licensed for 100 I/O channels and a IQ5-IO-16UIO module.
IQ5-00-150-24-16UIO IQ500150X0000000K1 IQ500 licensed for 150 I/O channels and a IQ5-IO-16UIO module.

Controller with I/O Capacity & IQVIEW SCD

సంక్షిప్త వివరణ Part Number / Product Code వివరణ
IQ5-00-50-SCD-24 IQ500-50X000S00000 IQ500 licensed for 50 I/O channels and IQVIEW SCD.
IQ5-00-100-SCD-24 IQ500100X000S00000 IQ500 licensed for 100 I/O channels and IQVIEW SCD.
IQ5-00-150-SCD-24 IQ500150X000S00000 IQ500 licensed for 150 I/O channels and IQVIEW SCD.

To add an IQ5-IO-16UIO module:

సంక్షిప్త వివరణ Part Number / Product Code వివరణ
IQ5-00-50-SCD-24-16UIO IQ500-50X000S000K1 IQ500 licensed for 50 I/O channels, IQVIEW SCD and an IQ5-IO-16UIO module.
IQ5-00-100-SCD-24-16UIO IQ500100X000S000K1 IQ500 licensed for 100 I/O channels, IQVIEW SCD and an IQ5-IO-16UIO module.
IQ5-00-150-SCD-24-16UIO IQ500150X000S000K1 IQ500 licensed for 150 I/O channels, IQVIEW SCD and an IQ5-IO-16UIO module.

Controller with I/O Capacity & Integration Functionality

సంక్షిప్త వివరణ Part Number / Product Code వివరణ
IQ5-00-16-INT50-24 IQ500-16X100000000 IQ500 licensed for 16 I/O channels and 50 integration points
IQ5-00-16-INT250-24 IQ500-16X300000000 IQ500 licensed for 16 I/O channels and 250 integration points.
IQ5-00-16-INT2500-24 IQ500-16X500000000 IQ500 licensed for 16 I/O channels and 2500 integration points.
IQ5-00-50-INT50-24 IQ500-50X100000000 IQ500 licensed for 50 I/O channels and 50 integration points.
IQ5-00-50-INT250-24 IQ500-50X300000000 IQ500 licensed for 50 I/O channels and 250 integration points.
IQ5-00-50-INT2500-24 IQ500-50X500000000 IQ500 licensed for 50 I/O channels and 2500 integration points.
IQ5-00-100-INT250-24 IQ500100X300000000 IQ500 licensed for 100 I/O channels and 250 integration points.
IQ5-00-100-INT2500-24 IQ500100X500000000 IQ500 licensed for 100 I/O channels and 2500 integration points.
IQ5-00-150-INT250-24 IQ500150X300000000 IQ500 licensed for 150 I/O channels and 250 integration points.
IQ5-00-150-INT2500-24 IQ500150X500000000 IQ500 licensed for 150 I/O channels and 2500 integration points.

To add an IQ5-IO-16UIO module:

సంక్షిప్త వివరణ Part Number / Product Code వివరణ
IQ5-00-50-INT50-24-16UIO IQ500-50X1000000K1 IQ500 licensed for 50 I/O channels, 50 integration points and a IQ5-IO-16UIO module.
IQ5-00-50-INT2500-24-16UIO IQ500-50X5000000K1 IQ500 licensed for 50 I/O channels, 2500 integration points and a IQ5-IO-16UIO module.
IQ5-00-100-INT2500-24-16UIO IQ500100X5000000K1 IQ500 licensed for 100 I/O channels, 2500 integration points.
IQ5-00-150-INT2500-24-16UIO IQ500150X5000000K1 IQ500 licensed for 150 I/O channels, 2500 integration points and a IQ5-IO-16UIO module.

Controller with I/O Capacity & IQ3/4 Bus Functionality

సంక్షిప్త వివరణ Part Number / Product Code వివరణ
IQ5-00-50-CAN-24 IQ500-50X00L000000 IQ500 licensed for 50 I/O channels and the IQ3/4 bus.
IQ5-00-100-CAN-24 IQ500100X00L000000 IQ500 licensed for 100 I/O channels and the IQ3/4 bus.
IQ5-00-150-CAN-24 IQ500150X00L000000 IQ500 licensed for 150 I/O channels and the IQ3/4 bus.

To add an IQ5-IO-16UIO module:

సంక్షిప్త వివరణ Part Number / Product Code వివరణ
IQ5-00-50-CAN-24-16UIO IQ500-50X00L0000K1 IQ500 licensed for 50 I/O channels, IQ3/4 bus and a IQ5-IO-16UIO module.
IQ5-00-100-CAN-24-16UIO IQ500100X00L0000K1 IQ500 licensed for 100 I/O channels, IQ3/4 bus and a IQ5-IO-16UIO module.
IQ5-00-150-CAN-24-16UIO IQ500150X00L0000K1 IQ500 licensed for 150 I/O channels, IQ3/4 bus and a IQ5-IO-16UIO module.

Controller with I/O Capacity & Network Routing Functionality

సంక్షిప్త వివరణ Part Number / Product Code వివరణ
IQ5-00-16-NC-24 IQ500-16X0N0000000 IQ500 licensed for 16 I/O channels and NC functionality.
IQ5-00-50-NC-24 IQ500-50X0N0000000 IQ500 licensed for 50 I/O channels and NC functionality.
IQ5-00-100-NC-24 IQ500100X0N0000000 IQ500 licensed for 100 I/O channels and NC functionality.
IQ5-00-150-NC-24 IQ500150X0N0000000 IQ500 licensed for 150 I/O channels and NC functionality.

To add an IQ5-IO-16UIO module:

సంక్షిప్త వివరణ Part Number / Product Code వివరణ
IQ5-00-50-NC-24-16UIO IQ500-50X0N00000K1 IQ500 licensed for 50 I/O channels, NC functionality and a IQ5-IO-16UIO module.
IQ5-00-100-NC-24-16UIO IQ500100X0N00000K1 IQ500 licensed for 100 I/O channels, NC functionality and a IQ5-IO-16UIO module.
IQ5-00-150-NC-24-16UIO IQ500150X0N00000K1 IQ500 licensed for 150 I/O channels, NC functionality and a IQ5-IO-16UIO module.

Controller with I/O Capacity, Integration & IQ3/4 Bus Functionality

సంక్షిప్త వివరణ Part Number / Product Code వివరణ
IQ5-00-50-INT250-CAN-24 IQ500-50X30L000000 IQ500 licensed for 50 I/O channels, 250 integration points and IQ3/4 bus.
IQ5-00-50-INT2500-CAN-24 IQ500-50X50L000000 IQ500 licensed for 50 I/O channels, 2500 integration points and IQ3/4 bus.
IQ5-00-100-INT250-CAN-24 IQ500100X30L000000 IQ500 licensed for 100 I/O channels, 250 integration points and IQ3/4 bus.
IQ5-00-100-INT2500-CAN-24 IQ500100X50L000000 IQ500 licensed for 100 I/O channels, 2500 integration points and IQ3/4 bus.

To add an IQ5-IO-16UIO module:

సంక్షిప్త వివరణ Part Number / Product Code వివరణ
IQ5-00-50-INT2500-CAN-24-16UIO IQ500-50X50L0000K1 IQ500 licensed for 50 I/O channels, 2500 integration points, IQ3/4 bus and a IQ5-IO- 16UIO module.
IQ5-00-100-INT2500-CAN-24-16UIO IQ500100X50L0000K1 IQ500 licensed for 100 I/O channels, 2500 integration points, IQ3/4 bus and a IQ5-IO- 16UIO module.

Controller with I/O Capacity, Integration and Network Routing Functionality

సంక్షిప్త వివరణ Part Number / Product Code వివరణ
IQ5-00-100-INT2500-NC-24 IQ500100X5N0000000 IQ500 licensed for 100 I/O channels, 2500 integration points, IQ3/4 bus and NC functionality.

To add an IQ5-IO-16UIO module:

సంక్షిప్త వివరణ Part Number / Product Code వివరణ
IQ5-00-100-INT2500-NC-24-16UIO IQ500100X5N00000K1 IQ500 licensed for 100 I/O channels, 2500 integration points, IQ3/4 bus, NC functionality and a IQ5-IO-16UIO module.

లైసెన్స్‌లు

Base Licences
Base licences are used for the initial licensing of the controller i.e. during installation/commissioning.
The following base licences are available where additional I/O channels (points) are needed. Additional licenses are available to provide support for node controller operation (NC), Modbus,

M-Bus and XNC integration (INT), and IQ3/4 bus operation (CAN):

  • IQ5-50-BASE IQ5 base license 50 points
  • IQ5-100-BASE IQ5 base license 100 points
  • IQ5-150-BASE IQ5 base license 150 points
  • IQ5-200-BASE IQ5 base license 200 points
  • IQ5-250-BASE IQ5 base license 250 points
  • IQ5-300-BASE IQ5 base license 300 points
  • IQ5-NC-BASE IQ5 base license for NC functionality
  • IQ5-INT-50-BASE IQ5 base license for Modbus, M-Bus and XNC integration 50 points
  • IQ5-INT-250-BASE IQ5 base license for Modbus, M-Bus and XNC integration 250 points
  • IQ5-INT-2500-BASE IQ5 base license for Modbus, M-Bus and XNC integration 2500 points
  • IQ5-CAN-BASE IQ5 base license for IQ3/4 bus (IQ3/4 I/O) modules
  • IQVIEW-SC-V-IQ5 License for IQVIEW Single Controller Display.

Upgrade Licences
Upgrade licenses are used allow for system expansion after the grace period. The following upgrade licences are available:

  • IQ5-16-50-UP IQ5 Upgrade license from 16 to 50 points
  • IQ5-50-100-UP IQ5 Upgrade license from 50 to 100 points
  • IQ5-100-150-UP IQ5 Upgrade license from 100 to 150 points
  • IQ5-150-200-UP IQ5 Upgrade license from 150 to 200 points
  • IQ5-200-250-UP IQ5 Upgrade license from 200 to 250 points
  • IQ5-250-300-UP IQ5 Upgrade license from 250 to 300 points
  • IQ5-NC-UP IQ5 upgrade license for NC functionality
  • IQ5-INT-50-UP IQ5 upgrade license for Modbus, M-Bus and XNC integration 50 points
  • IQ5-INT-250-UP IQ5 upgrade license for Modbus, M-Bus and XNC integration 250 points
  • IQ5-INT-2500-UP IQ5 upgrade license for Modbus, M-Bus and XNC integration 2500 points
  • IQ5-CAN-UP IQ5 upgrade license for IQ3/4 bus (IQ3/4 I/O)
  • IQVIEW-SC-V-IQ5 License for IQVIEW Single Controller Display.

ACCESSORY ORDER CODES

  • IQ5-IO-ADPT-2 Pack of 2 I/O bus wiring adapters (for IQ500 controller and IQ5-IO modules)
  • IQ5-IO-END-10 Pack of 10 spare end covers (for IQ500 controller and IQ5-IO modules)
  • IQ5-TCVR-140-10 Pack of 10 spare 140mm terminal covers (for IQ500)
  • DIN-CLIP-10 Spare DIN Clip (pack of 10)
  • SCRW-TB-3-BLK-50 Spare 3-way Screw Terminal Plug Black (pack of 50)
  • SCRW-TB-4-BLK-50 Spare 4-way Screw Terminal Plug Black (pack of 50)
  • SCRW-TB-3-GRY-50 Spare 3-way Screw Terminal Plug Grey (pack of 50)
  • PUSH-TB-3-BLK-50 Spare 3-way Push-fit Terminal Plug Black (pack of 50)
  • PUSH-TB-4-BLK-50 Spare 4-way Push-fit Terminal Plug Black (pack of 50)
  • PUSH-TB-3-GRY-50 Spare 3-way Push-fit Terminal Plug Grey (pack of 50)

స్పెసిఫికేషన్‌లు

ఎలక్ట్రికల్

  • సరఫరా వాల్యూమ్tage 24 Vac ±20%, 50/60 Hz, 24 Vdc ±20%
  • Supply Current 1.42A (34VA)@ 24Vac 0.52A (12.5W)(@24Vdc
  • ఓవర్‌వోల్tage protection 29 Vac or 40 Vdc.
  • Processor i.MX 8M Plus, quad Arm® Cortex®-A53 processor with speed up to 1.2 GHz integrated 800 MHz Arm® Cortex®-M7.
  • Memory FRAM: 512 KB, LPDDR4: 2 GB, EMMC: 8 GB.
  • Operating System LINUX/RTOS.

నిజ సమయ గడియారం

  • Accuracy (typical) ±0.3 s per day (±2 minutes per year).
  • Retention Supercap for up to 3 days (typical).
  • Cycle Time Sequence table 1s.

ఈథర్నెట్ నెట్‌వర్క్

  • పోర్టుల సంఖ్య 4
  • Transmission 10/100/1000 BASE-T (IEEE 802.3).
  • Connection RJ45, auto MDI-X.
  • Cable Type Cat 5e, UTP (unshielded twisted pair).
  • Distance (to hub) 100 m (328 ft) maximum.
  • Virtual CNCs 4 (8 in NC mode).
  • Addresses Not set by default – set to desired value in range 1 to 119 (excluding 2, 3, & 10)

USB Local Engineering Port

  • Connector USB type C.
  • Transmission USB 2.0.
  • Data Rate 480 Mbits/s. (limited to 19k2 by IQSET)
  • Distance 5 m (16 ft) maximum.
  • Address (sCNC) 1 to 119, (2, 3 and 10 not permitted) settable in software.

RS-485 పోర్ట్‌లు

  • Number of ports 3 (each galvanically isolated).
  • Protocols Modbus, M-Bus, MS/TP, XNC.
  • Termination 120 Ω switchable.
ప్రోటోకాల్ పరికర గణన కేబుల్ రకం గరిష్ట పొడవు* మీటర్లు (అడుగులు)
మోడ్బస్ 32 యూనిట్ లోడ్లు 120 Ω వక్రీకృత జత 900 (2953)
M-బస్సు 60 120 Ω వక్రీకృత జత 1000 (3280)
MS/TP 32 యూనిట్ లోడ్లు

64 IQECOలు**

120 Ω వక్రీకృత జత 1200 (4000)
ఎక్స్‌ఎన్‌సి 32 Depends on chosen application

* Dependent on cable specification and baud rate.

**There may be the IQ5 with up to 64 IQECOs or other manufacturer’s devices on the MS/TP trunk.

A separate limitation is that the MS/TP segment supports up to 32 ‘unit’ loads. The IQ5 presents a ¼ BACnet ‘unit’ load (ref. EIA-485), as does the IQECO; other manufacturer’s devices may have different unit loads.

T1L బస్సు

  • Compatibility IQ5-IO modules, IQ5-LAN-ADPT
  • Transmission 10BASE-T1L (IEE802.3cg).
  • Protocol MQTT compatible.
  • Maximum T1L devices 64 – only 1 can be IQ5-LAN-ADPT
  • Maximum IO Channels 300 total (depending on licence).
  • Bus Supply As per main power input.
  • Data Cable Type Screened twisted pair.

For further details see: IQ5-IO Modules Data Sheet (TA201481). IQ5-LAN-ADPT Current Loop LAN Adapter Data Sheet (TA201510)

IQ3/4 Bus

  • Compatibility IQ4/IO modules, XCITE/IO Modules.
  • Maximum Modules 30 (IQ4/IO only), 15 (XCITE/IO).
  • Maximum IO Channels 300 total (depending on licence).
  • Bus Supply 24 Vdc ±5% (separate PSU required).
  • Cable Type Belden 3084A (up to 100 m / 328 ft); Belden 7895A (up to 300 m / 1000 ft).

For further details see:

  • IQ4/IO Modules Data Sheet (TA201341);
  • XCITE/IO Modules Data Sheet (TA201352).

సూచికలు

  • సాధారణ స్థితి
  • Device ‘ring’ Multicolor LED
  • Service Multicolor LED
  • RS-485 Multicolor LED
  • LAN Multicolor LED
  • T1L IO Multicolor LED

ఈథర్నెట్ పోర్ట్స్

  • Left LED Green = 1000 mbps
  • Right LED Green = 100 mbps, Yellow = 10 mbps

మెకానికల్

  • Dimensions (WxHxD) 144.5 x 131 x 60 mm (5.69 x 5.16 x 2.36”).
  • మెటీరియల్ (ఎన్‌క్లోజర్) ఫ్లేమ్ రిటార్డెంట్ పాలికార్బోనేట్.
  • Weight 0.440 kg (0.97 lb).
  • Mounting (DIN Rail) IEC/EN 60715 TH35x7.5 or TH35x15 (1.5 mm maximum thickness).

కనెక్టర్లు

  • Power, RS-485, IQ3/4 bus
  • Connector type 2 part connector (5 mm pitch) with rising cage clamp screw terminals. Option for push-fit terminals.
  • Cable size 0.14 to 2.5 mm2 (22 to 12 AWG).
  • For UL compliance, the input power connections must be made using 18
  • AWG or larger wire rated at least 90°C (194 °F). For UL compliance use copper cable only.
    T1L Bus Integral spring contacts for inter-device connection. IQ5-IO-ADPT wiring adapter required for cable connection.
  • Ethernet Ports RJ45 connector.
  • USB Engineering Port USB Type C.
  • USB Expansion Port USB Type C (reserved for future use).

పర్యావరణ

  • ఆమోదాలు మరియు ధృవపత్రాలు
  • UL 60730-1, గృహ మరియు సారూప్య వినియోగం కోసం ఆటోమేటిక్ ఎలక్ట్రిక్ నియంత్రణల ప్రమాణం, పార్ట్ 1: సాధారణం
  • అవసరాలు;
    • CAN/CSA-E60730-1:13, ఆటోమేటిక్ కోసం ప్రామాణికం
  • గృహ మరియు సారూప్య వినియోగం కోసం విద్యుత్ నియంత్రణలు, భాగం
  • General Requirements;
    • UL916 కోసం కాంప్లిమెంటరీ లిస్టింగ్, CSA C22.2 No. 205;
    • SASO-approved;
    • CE-approved;
    • FCC పార్ట్ 15B-కంప్లైంట్.
  • Classification According to EN61326-1
  • పర్యావరణ పరిస్థితులు: Equipment intended for use in industrial environments.
  • నిర్మాణం: Independently mounted electronic control unit with fixed wiring; panel-mounted on DIN rail.
  • Action type 1.C.
  • రేటెడ్ ప్రేరణ వాల్యూమ్tage 24 V circuits: 500 V.
  • కాలుష్యం డిగ్రీ 2.
  • షాక్ క్లాస్ 0 నుండి రక్షణ (టెర్మినల్ కవర్లు లేకుండా);
  • క్లాస్ II (టెర్మినల్ కవర్లతో).
  • సాఫ్ట్‌వేర్ క్లాస్ A.
  • భవనాల శక్తి పనితీరు
  • EN ISO 52120-1 This controller, when used as part of a complete Trend Controls system AND when programmed with an appropriate application/strategy ,can support compliance with EN ISO 52120-1.
  • This enables buildings to achieve up to 30% energy cost savings (Energy classification “A”) alongside maximizing comfort and wellbeing.

EN12098-1 This control equipment complies with the performance specification defined in EN12098-1. With an appropriate application/strategy, it can make use of operation modes, scheduling, optimum start/stop, outside air temperature and frost protection to enhance the energy performance of buildings.

పరిసర పర్యావరణ పరిమితులు
Humidity 5 to 90%RH non-condensing.

ఉష్ణోగ్రత
Storage -40 to +70°C (-40 to +158°F).
Operating -25 to +60°C (-13 to +140°F).

గమనిక: 0°C (32°F) కంటే తక్కువ ఉష్ణోగ్రతల కోసం యూనిట్‌పై లేదా లోపల సంక్షేపణం లేకుండా ప్రత్యేక శ్రద్ధ తీసుకోవాలి.
Altitude ≤4000 m (13124 ft).
Pollution Degree 2 (only non-conducting pollution occurs).
Protection IP20 if mounted in an enclosure rated at IP20 or equivalent.

TREND-IQ500-Controller-FIG-28దయచేసి దీని గురించి లేదా ఏదైనా ఇతర ట్రెండ్ సాంకేతిక ప్రచురణ గురించి ఏవైనా వ్యాఖ్యలను పంపండి techpubs@trendcontrols.com

© 2025 హనీవెల్ ఉత్పత్తులు మరియు పరిష్కారాలు SARL, కనెక్ట్ చేయబడిన బిల్డింగ్ విభాగం. అన్ని హక్కులు ప్రత్యేకించబడ్డాయి. హనీవెల్ ప్రొడక్ట్స్ అండ్ సొల్యూషన్స్ SARL, ZA La Pièce, 16, 1180 Rolle, Switzerland యొక్క కనెక్ట్ చేయబడిన బిల్డింగ్ డివిజన్ కోసం మరియు దాని తరపున దాని అధీకృత ప్రతినిధి, ట్రెండ్ కంట్రోల్ సిస్టమ్స్ లిమిటెడ్ ద్వారా తయారు చేయబడింది.

ట్రెండ్ కంట్రోల్ సిస్టమ్స్ లిమిటెడ్ ఈ ప్రచురణను ఎప్పటికప్పుడు సవరించే హక్కును కలిగి ఉంది మరియు అటువంటి పునర్విమర్శలు లేదా మార్పుల గురించి ఎవరికైనా తెలియజేయాల్సిన బాధ్యత లేకుండా ఇందులోని కంటెంట్‌లో మార్పులు చేస్తుంది.

ట్రెండ్ కంట్రోల్ సిస్టమ్స్ లిమిటెడ్
Unit C, Foundry Lane. Horsham, West Sussex, RH13 5YZ, UK. Tel: +44 (0)1403 211888, www.trendcontrols.com

IQ500 Controller Data Sheet TA201480 Issue 7, 24-Oct-2025

పత్రాలు / వనరులు

ట్రెండ్ IQ500 కంట్రోలర్ [pdf] యూజర్ గైడ్
IQ500, IQ500 Controller, IQ500, Controller

సూచనలు

వ్యాఖ్యానించండి

మీ ఇమెయిల్ చిరునామా ప్రచురించబడదు. అవసరమైన ఫీల్డ్‌లు గుర్తించబడ్డాయి *